scholarly journals Advances in endoscopic resection: a review of endoscopic submucosal dissection (ESD), endoscopic full thickness resection (EFTR) and submucosal tunneling endoscopic resection (STER)

2021 ◽  
Vol 0 ◽  
pp. 0-0
Author(s):  
Ishita Dalal ◽  
Iman Andalib
2020 ◽  
Vol 08 (05) ◽  
pp. E611-E616 ◽  
Author(s):  
Marie-Anne Guillaumot ◽  
Maximilien Barret ◽  
Jérémie Jacques ◽  
Romain Legros ◽  
Mathieu Pioche ◽  
...  

Abstract Background and study aims Endoscopic full-thickness resection allows resection of early gastrointestinal neoplasms not amenable to conventional endoscopic resection techniques, due to their location, presence of submucosal fibrosis, or suspected deep mural invasion. It is typically achieved using a dedicated over-the-scope device (full-thickness resection device or FTRD). The aim of our study was to evaluate the feasibility, safety, and clinical outcomes of endoscopic full-thickness resection using an endoscopic submucosal dissection (ESD) knife. Patients and methods Consecutive patients who underwent full-thickness endoscopic resection at six tertiary care centers from August 2010 to June 2017 were retrospectively included. We conducted a comparative analysis of patient characteristics, technical success, adverse events, and time to discharge between patients treated by a full-thickness resection using an ESD knife. Results Twenty-one procedures were performed using an ESD knife. En-bloc resection and R0 resection rates were 95.2 % and 65 %, respectively. Clinical symptoms of perforation occurred in 66.7 %. There was no need for surgery or additional endoscopic procedures. Conclusion Endoscopic full-thickness resection of early colorectal neoplasms using an ESD knife might be feasible and safe. It allows complete resection of lesions with no limitation in size. The technique may be preferable to an other-the-scope resection device in lesions larger than 20 mm, and to surgery in selected cases of low-risk T1 colorectal carcinomas, non-lifting adenomas, submucosal tumors, or technically challenging lesion locations.


2020 ◽  
Vol 08 (10) ◽  
pp. E1302-E1307
Author(s):  
Zaheer Nabi ◽  
Radhika Chavan ◽  
Mohan Ramchandani ◽  
Zacharias Tsiamoulos ◽  
Jahanqeer Basha ◽  
...  

Abstract Background and study aims Recent innovations in devices and techniques have revolutionized the field of endoscopic resection procedures. In this study, we evaluated the safety and feasibility of endoscopic submucosal dissection and tunneling procedures with a novel, multipurpose bipolar device. Patients and methods Data from consecutive patients who underwent per-oral endoscopic myotomy (POEM), submucosal tunneling endoscopic resection (STER), and endoscopic submucosal dissection (ESD) using a novel bipolar device (December 2019 to February 2020) were analyzed retrospectively. Procedure duration, technical success, and adverse events (AEs) were recorded. Results A total of 10 procedures were performed using the novel bipolar device during the study period. The procedures included POEM (n = 7), STER for esophageal sub-epithelial tumor (n = 1), ESD for rectal polyp (n = 1), and gastric neuroendocrine tumor (n = 1). POEM was successfully completed in all patients. In patients who underwent STER and ESD, en-bloc resection was achieved in all. Mean procedure time for submucosal tunneling procedures (POEM and STER) was 59.12 ± 31.12 minutes. The procedures were completed without the requirement for exchange of accessories in eight cases (80 %). There were no major AEs. Mild and moderate AEs occurred during POEM and included capno-peritoneum (n = 1), retroperitoneal CO2 (n = 1), and empyema (n = 1). Conclusion ESD and tunneling procedures can be safely performed without the need for exchange of accessories using a novel bipolar device. Randomized comparison with conventional knives isrequired to confirm the utility of this device.


Sign in / Sign up

Export Citation Format

Share Document