bloc resection
Recently Published Documents


TOTAL DOCUMENTS

1168
(FIVE YEARS 432)

H-INDEX

46
(FIVE YEARS 5)

2022 ◽  
pp. 175319342110686
Author(s):  
Thanapon Chobpenthai ◽  
Chai-Sit Intuwongs ◽  
Siravich Suvithayasiri ◽  
Pichaya Thanindratarn ◽  
Termphong Phorkhar

We retrospectively reviewed the medical records of ten patients (five men and five women) who were treated in our unit for Campanacci Grade III giant cell tumour of the distal radius between July 2017 and December 2019. Following en bloc resection of a giant cell tumour of the distal radius, the wrist was reconstructed by transposing a vascularized pedicle graft from the ipsilateral ulnar shaft. The graft was fixed to the radial shaft and proximal carpal row with plates. At a mean follow-up of 23.5 months (range 18 to 31), bony union was achieved in all cases and there were no tumour recurrences. All patients had a good range of pronation and supination, but flexion and extension of the wrist was limited. DASH scores ranged from 5 to 11. This reconstruction method is a safe and effective procedure that provides good aesthetic outcomes, removes the need for microvascular techniques and reduces donor site morbidity. Level of evidence: IV


2022 ◽  
Vol 5 (1) ◽  
pp. e2141927
Author(s):  
Yagiz U. Yolcu ◽  
Jad Zreik ◽  
Waseem Wahood ◽  
Atiq ur Rehman Bhatti ◽  
Mohamad Bydon ◽  
...  

2022 ◽  
Vol 22 (1) ◽  
Author(s):  
Hiroaki Matsui ◽  
Naoto Tamai ◽  
Toshiki Futakuchi ◽  
Shunsuke Kamba ◽  
Akira Dobashi ◽  
...  

Abstract Background Endoscopic submucosal dissection (ESD) is technically difficult and requires considerable training. The authors have developed a multi-loop traction device (MLTD), a new traction device that offers easy attachment and detachment. We aimed to evaluate the utility of MLTD in ESD. Methods This ex vivo pilot study was a prospective, block-randomized, comparative study of a porcine stomach model. Twenty-four lesions were assigned to a group that undertook ESD using the MLTD (M-ESD group) and a group that undertook conventional ESD (C-ESD group) to compare the speed of submucosal dissection. In addition, the data of consecutive 10 patients with eleven gastric lesions was collected using electronic medical records to clarify the inaugural clinical outcomes of gastric ESD using MLTD. Results The median (interquartile range) speed of submucosal dissection in the M-ESD and C-ESD groups were 141.5 (60.9–177.6) mm2/min and 35.5 (20.8–52.3) mm2/min, respectively; submucosal dissection was significantly faster in the M-ESD group (p < 0.05). The rate of en bloc resection and R0 resection was 100% in both groups, and there were no perforation in either group. The MLTD attachment time was 2.5 ± 0.9 min and the MLTD extraction time was 1.0 ± 1.1 min. Clinical outcomes of MLTD in gastric ESD were almost the same as those of ex vivo pilot study. Conclusions MLTD increased the speed of submucosal dissection in ESD and was similarly effective when used by expert and trainee endoscopists without perforation. MLTD can potentially ensure a safer and faster ESD.


2022 ◽  
Vol 11 ◽  
Author(s):  
Mónica García-Sevilla ◽  
Rafael Moreta-Martinez ◽  
David García-Mato ◽  
Gema Arenas de Frutos ◽  
Santiago Ochandiano ◽  
...  

Adenoid Cystic Carcinoma is a rare and aggressive tumor representing less than 1% of head and neck cancers. This malignancy often arises from the minor salivary glands, being the palate its most common location. Surgical en-bloc resection with clear margins is the primary treatment. However, this location presents a limited line of sight and a high risk of injuries, making the surgical procedure challenging. In this context, technologies such as intraoperative navigation can become an effective tool, reducing morbidity and improving the safety and accuracy of the procedure. Although their use is extended in fields such as neurosurgery, their application in maxillofacial surgery has not been widely evidenced. One reason is the need to rigidly fixate a navigation reference to the patient, which often entails an invasive setup. In this work, we studied three alternative and less invasive setups using optical tracking, 3D printing and augmented reality. We evaluated their precision in a patient-specific phantom, obtaining errors below 1 mm. The optimum setup was finally applied in a clinical case, where the navigation software was used to guide the tumor resection. Points were collected along the surgical margins after resection and compared with the real ones identified in the postoperative CT. Distances of less than 2 mm were obtained in 90% of the samples. Moreover, the navigation provided confidence to the surgeons, who could then undertake a less invasive and more conservative approach. The postoperative CT scans showed adequate resection margins and confirmed that the patient is free of disease after two years of follow-up.


2022 ◽  
Vol 10 (01) ◽  
pp. E154-E162
Author(s):  
Choon Seng Chong ◽  
Mark D. Muthiah ◽  
Darren Jun Hao Tan ◽  
Cheng Han Ng ◽  
Xiong Chang Lim ◽  
...  

Abstract Background and study aims Evidence from recent trials comparing conventional endoscopic mucosal resection (EMR) to underwater EMR (UEMR) have matured. However, studies comparing UEMR to endoscopic submucosal dissection (ESD) are lacking. Hence, we sought to conduct a comprehensive network meta-analysis to compare the efficacy of UEMR, ESD, and EMR. Methods Embase and Medline databases were searched from inception to December 2020 for articles comparing UEMR with EMR and ESD. Outcomes of interest included rates of en bloc and complete polyp resection, risk of perforation and bleeding, and local recurrence. A network meta-analysis comparing all three approaches was conducted. In addition, a conventional comparative meta-analysis comparing UEMR to EMR was performed. Analysis was stratified according to polyp sizes (< 10 mm, ≥ 10 mm, and ≥ 20 mm). Results Twenty-two articles were included in this study. For polyps ≥ 10 mm, UEMR was inferior to ESD in achieving en bloc resection (P = 0.02). However, UEMR had shorter operating time for polyps ≥ 10 mm (P < 0.001), and ≥20 mm (P = 0.019) with reduced perforation risk for polyps ≥ 10 mm (P = 0.05) compared to ESD. In addition, en bloc resection rates were similar between UEMR and EMR, although UEMR had reduced recurrence for polyps ≥ 10 mm (P = 0.013) and ≥ 20 mm (P = 0.014). UEMR also had shorter mean operating than EMR for polyps ≥ 10 mm (P < 0.001) and ≥ 20 mm (P < 0.001). Risk of bleeding and perforation with UEMR and EMR were similar for polyp of all sizes. Conclusions UEMR has demonstrated technical and oncological outcomes comparable to ESD and EMR, along with a desirable safety profile. UEMR appears to be a safe and effective alternative to conventional methods for resection of polyps ≥ 10 mm.


Author(s):  
Salomé Kuntz ◽  
Anne-Florence Rouby ◽  
Elie Girsowicz ◽  
Philippe Bachelier ◽  
Anne Lejay ◽  
...  

Folia Medica ◽  
2021 ◽  
Vol 63 (6) ◽  
pp. 981-984
Author(s):  
Feridoun Sabzi ◽  
Aghigh Heydari ◽  
Reza Heidari Moghaddam ◽  
Atefeh Asadmobini

Bentall operation is considered a gold standard of surgery in the treatment of ascending aortic aneurysm. This operation with en-bloc resection of ascending aorta and aortic valve requires aortic valve with two coronary bottoms re-replacements in a prepared composite graft. The four important locations for the pseudoaneurysm include proximal and distal composite graft anastomosis and two coronary bottom sites. However, many complications have been reported with this technique but the most serious complication associated with this operation is defined as pseudoaneurysm. We report an exceedingly rare case of subaortic ring pseudoaneurysm in retro composite graft position enclosed by infected surgical that was used to control bleeding in this location. Dehiscence occurred between the aortic ring and the underlying left ventricular muscle. The aortic ring was separated from the underlying muscle by the high tensile strength of sewing ring sutures. The pseudoaneurysm compressing the left atrium without communicating with any cardiac chamber and presenting with high fever (39&deg;C), chills, a few months after Bentall operation. The patient underwent redo operation and repair of the dehiscence&rsquo;s site. The 6-month follow-up revealed no recurrence of a pseudoaneurysm. The uniqueness of this case report is related to the site of pseudoaneurysm between the aortic ring and underlying left ventricular muscle that have not been reported in the medical literature so far.


2021 ◽  
Vol 42 (1) ◽  
pp. 217-227
Author(s):  
KEN-ICHI OKADA ◽  
MANABU KAWAI ◽  
SEIKO HIRONO ◽  
SHINYA HAYAMI ◽  
MOTOKI MIYAZAWA ◽  
...  

2021 ◽  
Vol 11 (1) ◽  
pp. 141
Author(s):  
Haruka Fujinami ◽  
Akira Teramoto ◽  
Saeko Takahashi ◽  
Takayuki Ando ◽  
Shinya Kajiura ◽  
...  

This study aimed to assess the utility of the S-O clip during colorectal endoscopic submucosal dissection (ESD). We conducted a retrospective study on 185 patients who underwent colorectal ESD from January 2015 to January 2020. The patients were divided into two groups: before and after the introduction of the S-O clip. Forty-two patients underwent conventional ESD (CO group) and 29 patients underwent ESD using the S-O clip (SO group). We compared the surgery duration, dissection speed, en bloc resection rate, and complication rate between both groups. Compared with the CO group, the SO group had a significantly shorter surgery duration (70.7 ± 37.9 min vs. 51.2 ± 18.6 min; p = 0.017), a significantly higher dissection speed (15.1 ± 9.0 min vs. 26.3 ± 13.8 min; p < 0.001), a significantly higher en bloc resection rate (80.9% vs. 98.8%; p ≤ 0.001), and a significantly lower perforation rate (4.3% vs. 1.3%). In the right colon, the surgery duration was significantly shorter and the dissection speed was significantly higher in the SO group than in the CO group. Moreover, the rate of en bloc resection improved significantly in the right colon. S-O clip-assisted ESD reduces the procedure time and improves the treatment effects, especially in the right colon.


Sign in / Sign up

Export Citation Format

Share Document