Repair Integrity and Functional Outcome After Arthroscopic Double-Row Rotator Cuff Repair

2007 ◽  
Vol 89 (5) ◽  
pp. 953-960 ◽  
Author(s):  
Hiroyuki Sugaya ◽  
Kazuhiko Maeda ◽  
Keisuke Matsuki ◽  
Joji Moriishi
2013 ◽  
Vol 2013 ◽  
pp. 1-6 ◽  
Author(s):  
Ignacio Carbonel ◽  
Angel A. Martínez ◽  
Elisa Aldea ◽  
Jorge Ripalda ◽  
Antonio Herrera

Purpose. The purpose of this study was to evaluate the functional outcome and the tendon healing after arthroscopic double row rotator cuff repair of large and massive rotator cuff tears.Methods. 82 patients with a full-thickness large and massive rotator cuff tear underwent arthroscopic repair with double row technique. Results were evaluated by use of the UCLA, ASES, and Constant questionnaires, the Shoulder Strength Index (SSI), and range of motion. Follow-up time was 2 years. Magnetic resonance imaging (MRI) studies were performed on each shoulder preoperatively and 2 years after repair.Results. 100% of the patients were followed up. UCLA, ASES, and Constant questionnaires showed significant improvement compared with preoperatively (P<0.001). Range of motion and SSI in flexion, abduction, and internal and external rotation also showed significant improvement (P<0.001). MRI studies showed 24 cases of tear after repair (29%). Only 8 cases were a full-thickness tear.Conclusions. At two years of followup, in large and massive rotator cuff tears, an arthroscopic double row rotator cuff repair technique produces an excellent functional outcome and structural integrity.


2007 ◽  
Vol 89 (5) ◽  
pp. 953-960 ◽  
Author(s):  
Hiroyuki Sugaya ◽  
Kazuhiko Maeda ◽  
Keisuke Matsuki ◽  
and Joji Moriishi

2011 ◽  
Vol 40 (5) ◽  
pp. 1176-1185 ◽  
Author(s):  
Alexander M. DeHaan ◽  
Thomas W. Axelrad ◽  
Elizabeth Kaye ◽  
Lorenzo Silvestri ◽  
Brian Puskas ◽  
...  

2021 ◽  
pp. 036354652110154
Author(s):  
Adam M. Johannsen ◽  
Justin W. Arner ◽  
Bryant P. Elrick ◽  
Philip-C. Nolte ◽  
Dylan R. Rakowski ◽  
...  

Background: Modern rotator cuff repair techniques demonstrate favorable early and midterm outcomes, but long-term results have yet to be reported. Purpose: To determine 10-year outcomes and survivorship after arthroscopic double-row transosseous-equivalent (TOE) rotator cuff repair. Study Design: Case series; Level of evidence 4. Methods: The primary TOE rotator cuff repair procedure was performed using either a knotted suture bridge or knotless tape bridge technique on a series of patients with 1 to 3 tendon full-thickness rotator cuff tears involving the supraspinatus. Only patients who were 10 years postsurgery were included. Patient-reported outcomes were collected pre- and postoperatively, including American Shoulder and Elbow Surgeons (ASES), 12-Item Short Form Health Survey (SF-12), Single Assessment Numeric Evaluation (SANE), shortened version of the Disabilities of the Arm, Shoulder and Hand (QuickDASH), and satisfaction. Kaplan-Meier survivorship analysis was performed. Failure was defined as progression to revision surgery. Results: A total of 91 shoulders (56 men, 31 women) were included between October 2005 and December 2009. Mean follow-up was 11.5 years (range, 10.0-14.1 years). Of 91 shoulders, 5 (5.5%) failed and required revision surgery. Patient-reported outcomes for patients who survived were known for 80% (69/86). Outcomes scores at final follow-up were as follows: ASES, 93.1 ± 10.8; SANE, 87.5 ± 14.2; QuickDASH, 11.1 ± 13.5; and SF-12 physical component summary (PCS), 49.2 ± 10.1. There were statistically significant declines in ASES, SANE, and SF-12 PCS from the 5-year to 10-year follow-up, but none of these changes met the minimally clinically important difference threshold. Median satisfaction at final follow-up was 10 (range, 3-10). From this cohort, Kaplan-Meier survivorship demonstrated a 94.4% survival rate at a minimum of 10 years. Conclusion: Arthroscopic TOE rotator cuff repair demonstrates high patient satisfaction and low revision rates at a mean follow-up of 11.5 years. This information may be directly utilized in surgical decision making and preoperative patient counseling regarding the longevity of modern double-row rotator cuff repair.


Sign in / Sign up

Export Citation Format

Share Document