scholarly journals Modified Posterior Short-Segment Pedicle Screw Fixation at The Fracture Level for Treatment of Upper Lumbar Burst Fracture

Author(s):  
Xubiao Chen ◽  
Shixin Lu ◽  
Songjie Yang ◽  
Junshen Huang ◽  
Jiajun Huang ◽  
...  

Abstract Introduction Upper lumbar burst fractures (L1or L2) are often followed by bilateral pedicle screw fixation at the level of fracture using posterior short-segment pedicle instrumentation. However, it can aggravate the trauma to the fractured vertebra. We have introduced a modified technique of posterior short-segment instrumentation for the treatment of upper lumbar burst fracture. The aim of this study was to compare the clinical and radiologic results of modified technique versus conventional technique using posterior short-segment pedicle instrumentation in the treatment of upper lumbar burst fractures. Methods The data from 64 patients with upper lumbar burst fracture who had undergone posterior short-segment instrumentation from April 2014 to November 2018 in our clinic were evaluated in the present retrospective study. All the patients were divided into 2 groups according to the surgical technique, including 27 patients (modified order of intraoperative pedicle screw placement) in modified group and 37 patients (conventional order of intraoperative pedicle screw placement) in conventional group. The clinical outcomes and radiological parameters were evaluated preoperatively, postoperatively, at 3-month follow-up and final follow-up.Results Technical success was achieved in all 64 patients. The operation time of modified group(130.4±32.4min) is significantly longer than conventional group (115.3±26.8min, p<0.05). Significant improvement in the anterior vertebral height(AVH) ratio (97.9%±6.7% in modified group, 94.1%±7.8% in conventional group, p<0.05) was found postoperatively, (100.1%±9.7% in modified group, 89.6%±6.7% in conventional group, p<0.01) at the 3-month follow-up and(98.8%±7.7% in modified group, 90.9%±7.6% in conventional group, p<0.01) at the final follow-up. And post-operative correction of AVH ratio was significantly better in modified group (45.0%) than in conventional group (38.8%, p<0.01). There was 1 case of wound infection in both groups respectively. No instrument loosening or failure, or breakage was observed during follow-up.Conclusions Modified technique and conventional technique of posterior short-segment pedicle screw fixation for upper lumbar burst fractures both provided immediate stability and reduction of post-traumatic segmental kyphosis. In addition, modified technique of posterior short-segment pedicle screw fixation seems to be a promising method for upper lumbar burst fractures because it led to better reduction of fractured vertebra than in patients who received conventional technique.

2021 ◽  
Author(s):  
Ngoc Quyen Nguyen ◽  
Trong Hau Phan ◽  
Van Hong Vu

Abstract Background: Correction loss and hardware failure of short segment posterior pedicle screw fixation in treatment of thoracolumbar unstable burst fracture have been remaining a main concern. Several authors have introduced the procedures to solve these limitations including transforaminal interbody fusion (TIF). The purposes of this study were to evaluate the progressive kyphosis and implant failure of short-segment pedicle screw fixation combined with transforaminal interbody fusion in treatment of unstable thoracolumbar burst fracture.Methods: The retrospective study were enrolled in the patients with isolated unstable thoracolumbar burst fractures, Denis type IIB who were treated by posterior short fixation with TIF between January 2013 to January 2017. Patients were followed up for a minimum of one and half year. For evaluation of correction loss, % loss of anterior vertebral body heights (%AVB), vertebral kyphotic angle (VA) and regional kyphotic angle (RA) were collected preoperatively, postoperatively and at final follow-up. The hardware failure was assessed on radiological images at last follow-up. Results: There were 36 patients who met the inclusion criteria with a mean follow-up duration of 53 months. The mean correction loss of %AVB, VA and, RA were 10.2%, 2.9o and 5.6o, respectively. There were 6 patients (16.7%) with hardware failure at final follow-up. Conclusions: Short-segment posterior pedicle screw fixation with TIF using bone chip graft hasn’t prevented completely the hardware failure and progressive kyphosis in treatment of unstable thoracolumbar burst fracture.


2005 ◽  
Vol 18 (3) ◽  
pp. 1-6 ◽  
Author(s):  
Frank L. Acosta ◽  
Henry E. Aryan ◽  
William R. Taylor ◽  
Christopher P. Ames

Object Surgical intervention for thoracolumbar burst fractures is indicated for patients with neurological deficits and/or evidence of severe spinal instability. The goals of surgery are decompression, deformity correction, and stabilization. Nevertheless, the optimal surgical strategy to achieve these goals remains a subject of debate. Short-segment pedicle screw fixation is associated with a 20 to 50% incidence of pedicle screw failure and progressive spinal deformity. Initial biomechanical and clinical studies have shown that reinforcement of short-segment pedicle screw fixation with vertebroplasty improves spinal stability and decreases instrument failure rates. In this study, the authors describe their initial clinical experience with kyphoplasty used to augment short-segment pedicle screw fixation of traumatic lumbar burst fractures. Methods Five patients with traumatic burst fractures of the lumbar spine were included in this retrospective review of patients treated for this disorder at the University of California, San Diego and the University of California, San Francisco between 2002 and 2004. All patients underwent transpedicular kyphoplasty and short-segment pedicle screw fixation. The mean follow-up period was 10.6 months (range 6–18 months). All patients underwent short-segment pedicle screw fixation reinforced with polymethyl methacrylate kyphoplasty. The preoperative, postoperative, and follow-up plain x-ray films were evaluated. Radiographic analysis included measurements of kyphotic angulation, anterior vertebral body height, and evidence of bone fusion. Clinical evaluation was performed postoperatively and at follow-up review. Conclusions Based on the authors' initial experience, kyphoplasty supplementation may improve the long-term integrity of short-segment pedicle screw constructs and allow for improved rates of fusion and better clinical outcomes in patients with traumatic lumbar burst fractures.


2016 ◽  
Vol 9 (2) ◽  
pp. 81
Author(s):  
Md. Kamrul Ahsan ◽  
Zabed Zahangiri ◽  
M. A. Awwal ◽  
Naznin Zaman ◽  
Md. Hamidul Haque ◽  
...  

<p>The aim of this study was to evaluate the efficacy of inclusion of the fractured vertebra in short segment fixation in terms of clinical and the radiological outcomes in unstable thoracolumbar junction burst fractures at a minimum of 1 year follow-up. Records of 52 patients (age: 21-50 years) with thoracolumbar burst fracture (T10–L2) in Magerl Type A fractures underwent posterior pedicle screw fixation including the fractured vertebra. Clinical parameters were back pain using Visual Analogue Score (VAS) and disability using Oswestry disability index (ODI), neurological deficit (using ASIA grade) and radiologic parameters (Cobb angle, the kyphotic deformation and vertebral height) were measured before surgery and at 3, 6 and 12 months  post-operatively. The presence of screw breakage, screw pullout, peri-implant loosening, and rod breakage were considered as criteria for implant failure. The majority of fractures resulted due to falls (31 cases), and the remaining cases resulted from car accidents (21 cases). The fractured vertebral body level was L1, T12, L2, T11, and T10 in 23, 17, 6, 4 and 2 cases and achieved satisfactory clinical outcomes according to the modified Mcnab criteria 18, 25, 6 and 3 cases were considered to have excellent, good, fair, and poor outcome. The mean kyphotic angle at pre-, post-operative and final follow-up was 13.5 ± 6.3, 13.4 ± 4.3, 8.5 ± 6.  The average loss of kyphosis correction was 6.4 ± 5.2° at the final follow-up. The mean pre- and post-operative kyphotic deformation of vertebral body was 5.1 ± 3.2, 4.8 ± 2.3 and at final follow-up was 4.5 ± 4.0 (p&gt;0.05). The mean anterior and posterior vertebral height also showed significant improvements post-operatively, which were maintained at the final follow-up. The mean ODI and VAS scores at the end of 1 year were 17.4%, 1.7 respectively. There was no case of major complication after surgery and during the follow-up period. In conclusion, reduction of unstable thoracolumbar junction burst fracture can be achieved and maintained with the use of short-segment pedicle screw fixation including the fractured vertebra, avoiding the need for anterior reconstruction.</p><p> </p>


BMC Surgery ◽  
2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Beixi Bao ◽  
Qingjun Su ◽  
Yong Hai ◽  
Peng Yin ◽  
Yaoshen Zhang ◽  
...  

Abstract Background Treatment of congenital hemivertebra is challenging and data on long-term follow-up (≥ 5 years) are lacking. This study evaluated the surgical outcomes of posterior thoracolumbar hemivertebra resection and short-segment fusion with pedicle screw fixation for treatment of congenital scoliosis with over 5-year follow-up. Methods This study evaluated 27 consecutive patients with congenital scoliosis who underwent posterior thoracolumbar hemivertebra resection and short-segment fusion from January 2007 to January 2015. Segmental scoliosis, total main scoliosis, compensatory cranial curve, compensatory caudal curve, trunk shift, shoulder balance, segmental kyphosis, and sagittal balance were measured on radiographs. Radiographic outcomes and all intraoperative and postoperative complications were recorded. Results The segmental main curve was 40.35° preoperatively, 11.94° postoperatively, and 13.24° at final follow-up, with an average correction of 65.9%. The total main curve was 43.39° preoperatively, 14.13° postoperatively, and 16.06° at final follow-up, with an average correction of 60.2%. The caudal and cranial compensatory curves were corrected from 15.78° and 13.21° to 3.57° and 6.83° postoperatively and 4.38° and 7.65° at final follow-up, with an average correction of 69.2% and 30.3%, respectively. The segmental kyphosis was corrected from 34.30° to 15.88° postoperatively and 15.12° at final follow-up, with an average correction of 61.9%. A significant correction (p < 0.001) in segmental scoliosis, total main curve, caudal compensatory curves and segmental kyphosis was observed from preoperative to the final follow-up. The correction in the compensatory cranial curve was significant between preoperative and postoperative and 2-year follow-up (p < 0.001), but a statistically significant difference was not observed between the preoperative and final follow-up (p > 0.001). There were two implant migrations, two postoperative curve progressions, five cases of proximal junctional kyphosis, and four cases of adding-on phenomena. Conclusion Posterior thoracolumbar hemivertebra resection after short-segment fusion with pedicle screw fixation in congenital scoliosis is a safe and effective method for treatment and can achieve rigid fixation and deformity correction.


2016 ◽  
Vol 02 (04) ◽  
pp. e131-e138 ◽  
Author(s):  
Nitin Agarwal ◽  
Phillip Choi ◽  
Raymond Sekula

Introduction Traumatic thoracolumbar burst fracture is a common pathology without a clear consensus on best treatment approach. Minimally invasive approaches are being investigated due to potential benefits in recovery time and morbidity. We examine long-term resolution of symptoms of traumatic thoracolumbar burst fractures treated with percutaneous posterior pedicle screw fixation. Methods Retrospective clinical review of seven patients with spinal trauma who presented with thoracolumbar burst fracture from July 2012 to April 2013 and were treated with percutaneous pedicle screw fixation. Electronic patient charts and radiographic imaging were reviewed for initial presentation, fracture characteristics, operative treatment, and postoperative course. Results The patients had a median age of 29 years (range 18 to 57), and 57% were men. The median Thoracolumbar Injury Classification and Severity Scale score was 4 (range 2 to 9). All patients had proper screw placement and uneventful postoperative courses given the severity of their individual traumas. Five of seven patients were reached for long-term follow-up of greater than 28 months. Six of seven patients had excellent pain control and stability at their last follow-up. One patient required revision surgery for noncatastrophic hardware failure. Conclusion Percutaneous pedicle screw fixation for the treatment of unstable thoracolumbar burst fracture may provide patients with durable benefits and warrants further investigation.


2010 ◽  
Vol 10 (9) ◽  
pp. S136-S137
Author(s):  
Todd W. Peters ◽  
Suresh R. Chinthakunta ◽  
Mir Hussain ◽  
Saif Khalil

2020 ◽  
Vol 21 (1) ◽  
Author(s):  
Xuhong Xue ◽  
Sheng Zhao

Abstract Background The management of thoracolumbar burst fractures traditionally involves posterior pedicle screw fixation, but it has some drawbacks. The aim of this study is to evaluate the clinical and radiological outcomes of patients with thoracolumbar burst fractures. They were treated by a modified technique that monoaxial pedicle screws instrumentation and distraction-compression technology assisted end plate reduction. Methods From March 2014 to February 2016, a retrospective study including 42 consecutive patients with thoracolumbar burst fractures was performed. The patients had undergone posterior reduction and instrumentation with monoaxial pedicle screws. The fractured vertebrae were also inserted screws as a push point. The distraction -compression technology was used as assisting end plate reduction. All patients were followed up at a minimum of 2 years. These parameters including segmental kyphosis, severity of fracture, neurological function, canal compromise and back pain were evaluated in preoperatively, postoperatively and at the final follow-up. Results The average follow-up period was 28.9 ± 4.3 months (range, 24-39mo). No patients had postoperative implant failure at recent follow-up. The mean Cobb angle of the kyphosis was improved from 14.2°to 1.1° (correction rate 92.1%). At final follow-up there was 1.5% loss of correction. The mean preoperative wedge angle was improved from 17.1 ± 7.9°to 4.4 ± 3.7°(correction rate 74.3%). The mean anterior and posterior vertebral height also showed significant improvements postoperatively, which were maintained at the final follow-up(P < 0.05). The mean visual analogue scale (VAS) scores was 8 and 1.6 in preoperation and at the last follow-up, and there was significant difference (p < 0.05). Conclusion Based on our experience, distraction-compression technology can assist reduction of collapsed endplate directly. Satisfactory fracture reduction and correction of segmental kyphosis can be achieved and maintained with the use of monoaxial pedicle screw fixation including the fractured vertebra. It may be a good treatment approach for thoracolumbar burst fractures.


Sign in / Sign up

Export Citation Format

Share Document