Reproducibility of Choroidal Thickness Measurements in Hemodialysis Patients. A Spectral Domain Optical Coherence Tomography Study
Abstract PurposeTo investigate the effects of hemodialysis (HD) on the reproducibility of subfoveal choroidal thickness (SFCT) as measured by spectral domain-optical coherence tomography (SD-OCT)MethodsIn this study, 26 HD (26 eyes) patients had their pre- and post-HD SFCT measured, and the results were compared for reproducibility. Following a thorough ophthalmic examination, SD-OCT was performed three times in a row during a single session. The same physician measured SFCT after automatically identifying choroid with a software caliper. The reproducibility parameters, including intra-class correlation coefficients (ICCs), coefficients of variation (COV), and test-retest variability (TRTV) were then calculated.ResultsMales made up 53.85% of the 26 HD patients. There was a significant IOP difference between pre-HD (16.42±3.14 mmHg) and post-HD (14.21±2.78 mmHg) (P<0.001). SFCT decreased significantly from pre-HD 243.50±10.23 μm to post-HD 234.29±9.41 μm (P<0.001). ICC value increased significantly after HD, rising from 0.948 to 0.989 (P<0.001, for all). Pre- and post-HD COV values were 1.6% and 0.65%, respectively. Also, pre- and post-HD TRTV values were 7.864±1.996 μm and 3.074±1.536 μm, respectively.ConclusionThe reproducibility of SFCT as measured by OCT was lower during pre-HD compared to post-HD. Post-HD SD-OCT assessment appears to improve the reliability of clinical outcomes in the diagnosis and monitoring of HD patients.