scholarly journals Comparison of blood pressure measurements in the upper and lower extremities versus arterial blood pressure readings in children under general anesthesia

2019 ◽  
Vol Volume 12 ◽  
pp. 297-303 ◽  
Author(s):  
Seth Hayes ◽  
Rebecca Miller ◽  
Ambrish Patel ◽  
Dmitry Tumin ◽  
Hina Walia ◽  
...  
2015 ◽  
Vol 51 (5) ◽  
pp. 300-305 ◽  
Author(s):  
Martin J. Kennedy ◽  
Michele Barletta

The objectives of this study were to determine if Doppler (DOP) blood pressure measurements more closely estimate either invasive systolic or invasive mean arterial blood pressures (ISAP or IMAP, respectively) in small dogs under general anesthesia and to assess the ability of DOP to detect anesthesia-related hypotension in small dogs. Blood pressure measurements (n = 203) were obtained from 10 client-owned dogs. DOP, ISAP, and IMAP were recorded simultaneously, and the data were categorized into two groups: hypotensive (ISAP <90 mm Hg) and normotensive (ISAP ≥90 mm Hg and ≤160 mm Hg). DOP overestimated ISAP and IMAP in both the normotensive and hypotensive groups. The DOP was highly specific (97%) but poorly sensitive (56%) for detecting hypotension. The smallest bias was achieved when using DOP as an estimate of systolic arterial blood pressure in both normotensive and hypotensive dogs, suggesting that DOP measures systolic arterial blood pressure in dogs <5 kg. For dogs with hypotension, DOP met all of the performance criteria for noninvasive blood pressure monitors recommended by the American College of Veterinary Internal Medicine. DOP is an acceptably accurate and highly specific means of detecting hypotension in small dogs under general anesthesia.


2003 ◽  
Vol 98 (6) ◽  
pp. 1338-1344 ◽  
Author(s):  
Gilles Boccara ◽  
Alexandre Ouattara ◽  
Gilles Godet ◽  
Eric Dufresne ◽  
Michèle Bertrand ◽  
...  

Background Terlipressin, a precursor that is metabolized to lysine-vasopressin, has been proposed as a drug for treatment of intraoperative arterial hypotension refractory to ephedrine in patients who have received long-term treatment with renin-angiotensin system inhibitors. The authors compared the effectiveness of terlipressin and norepinephrine to correct hypotension in these patients. Methods Among 42 patients scheduled for elective carotid endarterectomy, 20 had arterial hypotension following general anesthesia that was refractory to ephedrine. These patients were the basis of the study. After randomization, they received either 1 mg intravenous terlipressin (n = 10) or norepinephrine infusion (n = 10). Beat-by-beat recordings of systolic arterial blood pressure and heart rate were stored on a computer. The intraoperative maximum and minimum values of blood pressure and heart rate, and the time spent with systolic arterial blood pressure below 90 mmHg and above 160 mmHg, were used as indices of hemodynamic stability. Data are expressed as median (95% confidence interval). Results Terlipressin and norepinephrine corrected arterial hypotension in all cases. However, time spent with systolic arterial blood pressure below 90 mmHg was less in the terlipressin group (0 s [0-120 s] vs. 510 s [120-1011 s]; P < 0.001). Nonresponse to treatment (defined as three boluses of terlipressin or three changes in norepinephrine infusion) occurred in zero and eight cases (P < 0.05), respectively. Conclusions In patients who received long-term treatment with renin-angiotensin system inhibitors, intraoperative refractory arterial hypotension was corrected with both terlipressin and norepinephrine. However, terlipressin was more rapidly effective for maintaining normal systolic arterial blood pressure during general anesthesia.


1979 ◽  
Vol 57 (s5) ◽  
pp. 387s-389s ◽  
Author(s):  
J. S. Floras ◽  
P. Fox ◽  
M. O. Hassan ◽  
J. V. Jones ◽  
P. Sleight ◽  
...  

1. Twenty-four hour intra-arterial blood pressure measurements and electrocardiograms were obtained from 12 subjects with untreated essential hypertension. 2. The patients kept records of their activity, paying particular attention to times of retiring to bed, and times of waking in the morning. 3. All subjects were treated with a single daily dose of atenolol (50 to 200 mg) for between 2 and 9 months, and then underwent a second 24 h blood pressure study. 4. Arterial blood pressure was lowered significantly throughout the 24 h period with a single daily dose of atenolol.


2015 ◽  
Vol 05 (05) ◽  
pp. 75-78
Author(s):  
Kenichi Satoh ◽  
Mami Chikuda ◽  
Ayako Ohashi ◽  
Miho Kumagai ◽  
Masahito Sato ◽  
...  

JAMA ◽  
1981 ◽  
Vol 245 (7) ◽  
pp. 703b-703
Author(s):  
E. K. Zsigmond

2004 ◽  
Vol 286 (6) ◽  
pp. H2408-H2415 ◽  
Author(s):  
Steven E. Whitesall ◽  
Janet B. Hoff ◽  
Alan P. Vollmer ◽  
Louis G. D'Alecy

Radiotelemetry of mouse blood pressure accurately monitors systolic pressure, diastolic pressure, heart rate, and locomotor activity but requires surgical implantation. Noninvasive measurements of indirect systolic blood pressure have long been available for larger rodents and now are being reported more frequently for mice. This study compared mouse systolic arterial blood pressure measurements using implanted radiotelemetry pressure transducer with simultaneous tail-cuff measurements in the same unanesthetized mice. The pressure range for comparison was extended by inducing experimental hypertension or by observations of circadian elevations between 3 AM and 6 AM. Both trained and untrained tail-cuff operators used both instruments. Every effort was made to follow recommended manufacturer's instructions. With the initial flow-based tail-cuff instrument, we made 671 comparisons (89 sessions) and found the slope of the linear regression to be 0.118, suggesting poor agreement. In an independent assessment, 277 comparisons (35 sessions) of radiotelemetry measurements with the pulse based tail-cuff instrument were made. The slope of the linear regression of the simultaneous measurements of systolic pressures was 0.98, suggesting agreement. Bland-Altman analysis also supported our interpretation of the linear regression. Thus although reliable systolic pressure measurements are possible with either tail-cuff or radiotelemetry techniques, in our hands some tail-cuff instruments fail to accurately detect elevated blood pressures. These data, however, do not distinguish whether this instrument-specific tail-cuff failure was due to operator or instrument inadequacies. We strongly advise investigators to obtain an independent and simultaneous validation of tail-cuff determinations of mouse blood pressure before making critical genotyping determinations.