scholarly journals Clinical Outcomes with a Novel Extended Depth of Focus Presbyopia-Correcting Intraocular Lens: Pilot Study

2021 ◽  
Vol Volume 15 ◽  
pp. 1215-1221
Author(s):  
María T Iradier ◽  
Verónica Cruz ◽  
Naty Gentile ◽  
Priscila Cedano ◽  
David P Piñero
2018 ◽  
Vol 08 (03) ◽  
pp. 161-170 ◽  
Author(s):  
Francisco Poyales ◽  
Nuria Garzón ◽  
Concepción Poyales ◽  
Blanca Poyales

2019 ◽  
Vol 35 (7) ◽  
pp. 426-433 ◽  
Author(s):  
Steven C. Schallhorn ◽  
David Teenan ◽  
Jan A. Venter ◽  
Stephen J. Hannan ◽  
Julie M. Schallhorn

Author(s):  
Makoto Inoue ◽  
Nina Teresa Aicher ◽  
Yuji Itoh ◽  
Hiroko Bissen-Miyajima ◽  
Akito Hirakata

2019 ◽  
Author(s):  
Bert C. Giers ◽  
Ramin Khoramnia ◽  
Dorottya Varadi ◽  
Hannah Wallek ◽  
Hyeck Soo Son ◽  
...  

Abstract Background: Evaluation of clinical and functional results of a new extended depth of focus intraocular lens (EDOF-IOL). Methods: Fourteen cataract patients (twenty-eight bilateral implantations) were assessed for uncorrected (UDVA) and corrected (CDVA) distance visual acuities; uncorrected (UNVA), distance-corrected (DCNVA) and best corrected (CNVA) near visual acuities; and uncorrected (UIVA) and distance-corrected (DCIVA) intermediate visual acuities - as well as binocular defocus curves. Photopic and mesopic contrast sensitivity was recorded. Reading acuity was evaluated using an electronic reading desk at fixed distances and at the patient’s preferred near and intermediate distances. Visual symptoms were assessed with a halo and glare simulator plus a patient questionnaire which also recorded quality of life. Results: Median postoperative monocular UDVA was 0.13logMAR (range -0.08 to 0.42logMAR), median CDVA was -0.01logMAR (range -0.20 to 0.22logMAR), median UIVA at 80 cm was -0.05logMAR (range -0.18 to 0.58logMAR) and median UNVA at 40 cm was 0.14logMAR (range -0.10 to 0.64logMAR). Binocular uncorrected reading acuity was 0.10logMAR at 40 cm and 0.11logMAR at 80 cm. Patients preferred a median intermediate reading distance of 62.8 cm over the predetermined 80 cm, which allowed them to read smaller letter size but did not improve reading acuity. Patients reported a high rate of spectacle independence and satisfaction in everyday life and little to no dysphotopsia. Conclusion: The Mini WELL Ready IOL provided good postoperative functional results at far and intermediate distances and improved the visual and reading acuity at reading distance. The lens caused little to no dysphotopsia.


Eye ◽  
2018 ◽  
Vol 33 (3) ◽  
pp. 404-410 ◽  
Author(s):  
Giacomo Savini ◽  
Nicole Balducci ◽  
Claudio Carbonara ◽  
Scipione Rossi ◽  
Manuel Altieri ◽  
...  

2019 ◽  
Vol 19 (1) ◽  
Author(s):  
Bert C. Giers ◽  
Ramin Khoramnia ◽  
Dorottya Varadi ◽  
Hannah Wallek ◽  
Hyeck-Soo Son ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document