Low and high dose aprotinin are similar in reducing blood loss during cardiac surgery

1991 ◽  
Vol &NA; (782) ◽  
pp. 9
Author(s):  
&NA;
1994 ◽  
Vol 22 (5) ◽  
pp. 529-533 ◽  
Author(s):  
M. J. Swart ◽  
P. C. Gordon ◽  
P. B. Hayse-Gregson ◽  
R. A. Dyer ◽  
A. L. Swanepoel ◽  
...  

Fifty patients undergoing primary coronary artery bypass surgery and 50 patients undergoing valve surgery received either high-dose aprotinin (2 million units loading dose, 2 million units added to the CPB prime, and 500,000 units/hr maintenance infusion) or placebo. Mean postoperative blood loss in the first six hours was reduced from 321 ml in the placebo group to 172 ml in the aprotinin group (95% confidence interval (CI) for difference = 95 to 189 ml). Seven patients in the placebo group and 16 patients in the aprotinin group did not require transfusion with homologous blood. This study adds to the growing body of evidence that the administration of high-dose aprotinin reduces blood loss and blood transfusion requirements associated with primary cardiac surgery.


1989 ◽  
Vol 71 (Supplement) ◽  
pp. A7 ◽  
Author(s):  
W. Dietrich ◽  
M. Jochum ◽  
W. Schramm ◽  
G. Blümel ◽  
J. A. Richter

2014 ◽  
Vol 120 (3) ◽  
pp. 590-600 ◽  
Author(s):  
Stéphanie Sigaut ◽  
Benjamin Tremey ◽  
Alexandre Ouattara ◽  
Roland Couturier ◽  
Christian Taberlet ◽  
...  

Abstract Background: The optimal dose of tranexamic acid (TA) is still an issue. The authors compared two doses of TA during cardiac surgery in a multicenter, double-blinded, randomized study. Methods: Patients were stratified according to transfusion risk, then randomized to two TA doses: 10 mg/kg bolus followed by 1 mg·kg−1·h−1 infusion (low dose) until the end of surgery or 30 mg/kg bolus followed by 16 mg·kg−1·h−1 infusion (high dose). The primary endpoint was the incidence of blood product transfusion up to day 7. Secondary ones were incidences of transfusion for each type of blood product and amounts transfused, blood loss, repeat surgery, TA-related adverse events, and mortality. Results: The low-dose group comprised 284 patients and the high-dose one 285. The primary endpoint was not significantly different between TA doses (63% for low dose vs. 60% for high dose; P = 0.3). With the high dose, a lower incidence of frozen plasma (18 vs. 26%; P = 0.03) and platelet concentrate (15 vs. 23%; P = 0.02) transfusions, lower amounts of blood products (2.5 ± 0.38 vs. 4.1 ± 0.39; P = 0.02), fresh frozen plasma (0.49 ± 0.14 vs.1.07 ± 0.14; P = 0.02), and platelet concentrates transfused (0.50 ± 0.15 vs. 1.13 ± 0.15; P = 0.02), lower blood loss (590 ± 50.4 vs. 820 ± 50.7; P = 0.01), and less repeat surgery (2.5 vs. 6%; P = 0.01) were observed. These results are more marked in patients with a high risk for transfusion. Conclusions: A high dose of TA does not reduce incidence of blood product transfusion up to day 7, but is more effective than a low dose to decrease transfusion needs, blood loss, and repeat surgery.


1992 ◽  
Vol 6 (3) ◽  
pp. 319-323 ◽  
Author(s):  
Catherine Vedrinne ◽  
Claude Girard ◽  
Olivier Jegaden ◽  
Pascale Blanc ◽  
Hélene Bouvier ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document