scholarly journals Radiological Consequences of Beam Loss at Front End by FLUKA during Top-off Injection into the Storage Ring for PROJECT Beamlines

2014 ◽  
Author(s):  
Zhenghua Xia
Keyword(s):  
2014 ◽  
Vol 26 (10) ◽  
pp. 105101
Author(s):  
邓庆勇 Deng Qingyong ◽  
曹建社 Cao Jianshe ◽  
岳军会 Yue Junhui ◽  
魏源源 Wei Yuanyuan ◽  
麻惠洲 Ma Huizhou ◽  
...  

2016 ◽  
Author(s):  
Hiroshi Miyauchi ◽  
Toshihiro Tahara ◽  
Seiji Asaoka

Author(s):  
Michiko G. Minty ◽  
Frank Zimmermann

AbstractIn order to preserve the beam quality, accurate knowledge of the transverse optics and its correction is most often mandatory. For example, if the distribution of a beam injected into a storage ring is not matched to the ring optics, the emittance will grow due to filamentation. Or, if there is a significant optics error, e.g., induced by a strength error in a quadrupole magnet, the beam envelope may vary strongly. The resulting reduction in dynamic aperture may then lead to enhanced beam loss.


2013 ◽  
Vol 20 (5) ◽  
pp. 667-682 ◽  
Author(s):  
P. R. Willmott ◽  
D. Meister ◽  
S. J. Leake ◽  
M. Lange ◽  
A. Bergamaschi ◽  
...  

The Materials Science beamline at the Swiss Light Source has been operational since 2001. In late 2010, the original wiggler source was replaced with a novel insertion device, which allows unprecedented access to high photon energies from an undulator installed in a medium-energy storage ring. In order to best exploit the increased brilliance of this new source, the entire front-end and optics had to be redesigned. In this work, the upgrade of the beamline is described in detail. The tone is didactic, from which it is hoped the reader can adapt the concepts and ideas to his or her needs.


1998 ◽  
Vol 5 (3) ◽  
pp. 162-167 ◽  
Author(s):  
H. Kamitsubo

SPring-8 is a third-generation synchrotron radiation source operating in the soft and hard X-ray region. It consists of an injector linac of 1 GeV, a booster synchrotron of 8 GeV and a storage ring with a natural emittance of 5.9 nm rad. The storage ring can accommodate 61 beamlines in total, and 26 of them are under construction. The project has been carried out jointly by JAERI and RIKEN and construction of the facility started in 1991. Commissioning of the injector linac was started in August 1996 and an 8 GeV electron beam was injected into the storage ring in March 1997. The first synchrotron radiation from a bending magnet was observed at the front end of the beamline on 25 March and radiation from an undulator was observed on 23 April. On-beam testing of seven beamlines, four of them from in-vacuum undulators and three from bending magnets, started in July. The maximum stored current is currently fixed at 20 mA and the lifetime at maximum current is longer than 20 h. The dedication is scheduled for October 1997.


Sign in / Sign up

Export Citation Format

Share Document