scholarly journals Comparative study between conventional open spine pedicle screw fixation surgery minimally invasive percutaneous pedicle screw fixation in the management of thoracolumbar spine fracture in adult

2016 ◽  
Vol 2 (4c) ◽  
pp. 154-159
Author(s):  
Ajay MB ◽  
◽  
Vijayakumar AV ◽  
2018 ◽  
Vol 16 (4) ◽  
pp. E121-E121 ◽  
Author(s):  
Corey T Walker ◽  
Jakub Godzik ◽  
David S Xu ◽  
Nicholas Theodore ◽  
Juan S Uribe ◽  
...  

Abstract Lateral interbody fusion has distinct advantages over traditional posterior approaches. When adjunctive percutaneous pedicle screw fixation is required, placement from the lateral decubitus position theoretically increases safety and improves operative efficiency by obviating the need for repositioning. However, safe cannulation of the contralateral, down-side pedicles remains technically challenging and often prohibitive. In this video, we present the case of a 59-yr-old man with refractory back pain and bilateral lower extremity radiculopathy that was worse on the left than right side. The patient provided written informed consent before undergoing treatment. We performed minimally invasive single-position lateral interbody fusion with robotic (ExcelsiusGPS, Globus Medical Inc, Audubon, Pennsylvania) bilateral percutaneous pedicle screw fixation for the treatment of asymmetric disc degeneration, dynamic instability, and left paracentral disc herniation with corresponding stenosis at the L3-4 level. A left-sided minimally invasive transpsoas lateral interbody graft was placed with fluoroscopic guidance. Without changing the position of the patient or breaking the sterile field, an intraoperative cone-beam computed tomography image was obtained for navigational screw placement with stereotactic trackers in the iliac spine. Screw trajectories were planned using the robotic navigation software and were placed percutaneously in the bilateral L3 and L4 pedicles using the robotic arm. Concomitant lateral fluoroscopy may be used if desired to ensure the fidelity of the robotic guidance. The patient recovered well postoperatively and was discharged home within 36 h, without complication. Single-position lateral interbody fusion and percutaneous pedicle screw fixation can be accomplished using robotic-assisted navigation and pedicle screw placement. Used with permission from Barrow Neurological Institute.


2020 ◽  
Vol 10 (11) ◽  
pp. 303-312
Author(s):  
Katsunori Fukutake ◽  
Akihito Wada ◽  
Daisuke Kamakura ◽  
Kazumasa Nakamura ◽  
Shintaro Tsuge ◽  
...  

2013 ◽  
Vol 35 (2) ◽  
pp. E2 ◽  
Author(s):  
Andrew J. Grossbach ◽  
Nader S. Dahdaleh ◽  
Taylor J. Abel ◽  
Gregory D. Woods ◽  
Brian J. Dlouhy ◽  
...  

Object Flexion-distraction injuries occur due to distractive forces causing disruption of the posterior and middle spinal columns. These fractures classically consist of a fracture line through the posterior bony elements; involvement of the posterior ligamentous complex is, however, common. Surgical treatment is often required for these unstable injuries to avoid neurological deterioration and posttraumatic kyphosis, and the surgery traditionally consists of an open posterior approach with instrumented fusion. Percutaneous pedicle screw fixation for these injuries, with the goal of minimal tissue disruption and preservation of normal anatomy while achieving adequate stabilization, has recently been reported in the literature, but to date, a direct comparative study comparing open and percutaneous fixation has not been reported. The authors report their experience treating these fractures with both techniques and review the available literature. Methods Patients with flexion-distraction injury who were treated between May 2003 and March 2013 were prospectively followed. American Spinal Injury Association scores and degree of kyphotic angulation were recorded at admission, discharge, and follow-up. Data regarding intraoperative blood loss and operative time were obtained from a chart review. Patients treated with open versus minimally invasive procedures were compared. Results The authors identified 39 patients who suffered flexion-distraction injuries and were treated at their institution during the specified period; one of these patients declined surgery. All had injury to the posterior ligamentous complex. Open surgical procedures with pedicle screw fixation and posterolateral fusion were performed in 27 patients, while 11 patients underwent minimally invasive pedicle screw placement. Overall, there was improvement in kyphotic angulation at the time of discharge as well as most recent follow-up in both the open surgery and minimally invasive surgery (MIS) groups. The authors found no significant difference in American Spinal Injury Association score or the degree of kyphotic angulation between the MIS and open surgery groups. There was a trend toward shorter operative time for the MIS group, and patients who underwent minimally invasive procedures had significantly less blood loss. Conclusions Minimally invasive percutaneous pedicle screw fixation appears to have similar efficacy in the treatment of flexion-distraction injuries and it allows for reduced blood loss and tissue damage compared with open surgical techniques. Therefore it should be considered as an option for the treatment of this type of injury.


Sign in / Sign up

Export Citation Format

Share Document