scholarly journals Gantry orientation effect on the neutron and capture gamma ray dose equivalent at the maze entrance door in radiation therapy

2012 ◽  
Vol 27 (1) ◽  
pp. 70-74 ◽  
Author(s):  
Hosein Ghiasi ◽  
Asghar Mesbahi

In the present study, the effect of gantry orientation on the photoneutron and capture gamma dose calculations for maze entrance door was evaluated. A typical radiation therapy room made of ordinary concrete was simulated using MCNPX Monte Carlo code. Gantry rotation was simulated at eight different angles around the isocenter. Both neutron and capture gamma dose vary considerably with gantry angle. The ratios of the maximum to the minimum values for neutron and capture gamma dose equivalents were 1.9 and 1.4, respectively. On the other hand, comparison of the Monte Carlo calculated mean value over all orientations with Monte Carlo calculated neutron and gamma dose showed that the Wu-McGinley method differed by 5% and 2%, respectively. However, for more conservative shielding calculations, factors of 1.6 and 1.3 should be applied to the calculated neutron and capture gamma doses at downward irradiation. Finally, it can be concluded that the gantry angle influences neutron and capture gamma dose at the maze entrance door and it should be taken into account in shielding considerations.

2011 ◽  
Vol 26 (2) ◽  
pp. 147-152 ◽  
Author(s):  
Asghar Mesbahi ◽  
Hosein Ghiasi ◽  
Rabee Mahdavi

Neutron and capture gamma ray dose equivalent along the maze and entrance door of a radiation therapy room made of high density concrete was calculated using analytical and Monte Carlo methods. The room geometry and the 18 MV photon beam of a Varian 2100C/D linac were simulated using MCNPX MC code. Four analytical methods including Kersey, French, McCall, and Wu-McGinley methods were used in the current study. Average difference of 13-30% was seen between analytical and MC methods along the maze for photoneutron calculations. The difference between Wu-McGinley and MC methods was about 17% for capture gamma ray calculations. It was concluded that the analytical methods overestimate both neutron and capture gamma ray dose equivalents compared to MC. Moreover, it was shown that the analytical methods can be used as conservative estimators for neutron and capture gamma calculations.


2010 ◽  
Vol 55 (13) ◽  
pp. 3917-3936 ◽  
Author(s):  
Juergen Karg ◽  
Stefan Speer ◽  
Manfred Schmidt ◽  
Reinhold Mueller

2020 ◽  
Vol 24 (2) ◽  
pp. 128-134
Author(s):  
H. Alhamada ◽  
S. Simon ◽  
C. Philippson ◽  
C. Vandekerkhove ◽  
Y. Jourani ◽  
...  

2020 ◽  
Vol 76 ◽  
pp. 166-172
Author(s):  
Tordis Johnsen Dahle ◽  
Espen Rusten ◽  
Camilla Hanquist Stokkevåg ◽  
Antti Silvoniemi ◽  
Andrea Mairani ◽  
...  