Effect of fatigue and sex on isokinetic torque values in water polo athletes

Author(s):  
Michele LEBLANC ◽  
Bobby J. LEE ◽  
Steven A. HAWKINS
1992 ◽  
Vol 1 (4) ◽  
pp. 275-283 ◽  
Author(s):  
Andrew C. Fry ◽  
Dawn R. Powell ◽  
William J. Kraemer

Although it is generally accepted that human performance must be assessed in a manner specific to the training, previous studies have violated this principle. In order to determine the validity of evaluating short-term resistance training programs with isometric and isokinetic measures, 23 recreationally active males participated in an 8-week training program. Subjects were randomly divided into barbell squat, hip sled, leg extension, and control groups. Pre- and posttesting of quadriceps strength was performed with a Cybex isokinetic dynamometer. Six angle-specific torques (N.m) were determined at 0 rad-s-1 and 1.05 rad-s-1. Ten RM training loads increased significantly for all groups that trained. Isometric torque values differed significantly from isokinetic torque values at 30, 60, 75, and 90° of leg flexion for all groups. No significant torque increases from pre- to posttest were observed for any group at any limb angle for either isometric or isokinetic testing, or for isokinetic peak torque. This indicates that strength increases during short-term dynamic external resistance exercise are not adequately assessed with either isometric or isokinetic evaluations.


1992 ◽  
Vol 2 (2) ◽  
pp. 114-120 ◽  
Author(s):  
S. Kushner ◽  
D. Reid ◽  
L. Saboe ◽  
T. Penrose

1990 ◽  
Vol 11 (12) ◽  
pp. 612-616 ◽  
Author(s):  
Michael Leslie ◽  
James Zachazewski ◽  
Phyllis Browne

1991 ◽  
Vol 19 (1) ◽  
pp. 72-75 ◽  
Author(s):  
William C. McMaster ◽  
Susan C. Long ◽  
Vincent J. Caiozzo

Author(s):  
Olga Kouli ◽  
Ekaterini Kouvarda ◽  
Konstantinos Astrapellos ◽  
Athanasios Papaioannou
Keyword(s):  

Author(s):  
Arda Ozdiler ◽  
suleyman dayan ◽  
Burc Gencel ◽  
Gulbahar Isık-Ozkol

This in vitro study evaluated the influence of taper angles on the internal conical connections of implant systems and of the application of chlorhexidine gel as an antibacterial agent or a polyvinyl siloxane (PVS) sealant on the reverse torque values of abutment screws after dynamic loading. The current study tested four implant systems with different taper angles (5.4°, 12°, 45°, and 60°). Specimens were divided into three groups: control (neither chlorhexidine gel filled nor silicone sealed), 2% chlorhexidine gel-filled or silicone-sealed group, and group subjected to a dynamic load of 50 N at 1 Hz for 500,000 cycles prior to reverse torque measurements. Quantitative positive correlation was observed between the taper angle degree and the percentage of tightening torque loss. However, this correlation was significant only for the 60° connection groups except in the group in which a sealant was applied ( p = 0.013 for the control group, p = 0.007 for the chlorhexidine group). Percentages of decrease in the torque values of the specimens with silicone sealant application were significantly higher compared with both the control and chlorhexidine groups ( p = 0.001, p = 0.002, p = 0.001, and p = 0.002, respectively, according to the increasing taper angles); the percentage of decrease in torque values due to chlorhexidine application was statistically insignificant when compared with the control group. The application of gel-form chlorhexidine as an antibacterial agent does not significantly affect the stability of the implant–abutment connection under dynamic loads. PVS sealants may cause screw loosening under functional loads.


Author(s):  
Valerio Viero ◽  
Tamara Triossi ◽  
Daniele Bianchi ◽  
Alessandro Campagna ◽  
Giovanni Melchiorri

Sign in / Sign up

Export Citation Format

Share Document