scholarly journals A protocol for accurate radiochromic film dosimetry using Radiochromic.com

2021 ◽  
Vol 55 (3) ◽  
pp. 369-378
Author(s):  
Ignasi Méndez ◽  
Juan José Rovira-Escutia ◽  
Bozidar Casar

Abstract Background Radiochromic films have many applications in radiology and radiation therapy. Generally, the dosimetry system for radiochromic film dosimetry is composed of radiochromic films, flatbed scanner, and film analysis software. The purpose of this work is to present the effectiveness of a protocol for accurate radiochromic film dosimetry using Radiochromic.com as software for film analysis. Materials and methods Procedures for image acquisition, lot calibration, and dose calculation are explained and analyzed. Radiochromic.com enables state-of-the-art models and corrections for radiochromic film dosimetry, such as the Multigaussian model for multichannel film dosimetry, and lateral, inter-scan, and re-calibration corrections of the response. Results The protocol presented here provides accurate dose results by mitigating the sources of uncertainty that affect radiochromic film dosimetry. Conclusions Appropriate procedures for film and scanner handling in combination with Radiochromic.com as software for film analysis make easy and accurate radiochromic film dosimetry feasible.

2016 ◽  
Vol 61 (21) ◽  
pp. 7704-7724 ◽  
Author(s):  
Andreas A Schoenfeld ◽  
Soeren Wieker ◽  
Dietrich Harder ◽  
Bjoern Poppe

2012 ◽  
Vol 39 (6Part31) ◽  
pp. 4009-4009
Author(s):  
D Lewis ◽  
S Devic ◽  
N Tomic ◽  
S Aldelaijan ◽  
F DeBlois ◽  
...  

2018 ◽  
Vol 18 (1) ◽  
pp. 55-62
Author(s):  
Muhammad Isa Khan ◽  
Muhammad Bilal Tahir ◽  
Muhammad Rafique ◽  
Tahir Iqbal ◽  
Sabiha Zulfiqar ◽  
...  

AbstractPurposeThis work reports our study to commission a radiochromic film dosimetry system using the timely EBT3 film. We carried out dosimetric evaluations on different characteristics of photon beams (e.g., flatness, symmetry and penumbra) in radiation dose delivery.Materials and MethodsA Varian linear accelerator producing 6 and 15 MV photon beams with 120 multi-leaf collimator was used in this study. PTW ionisation chamber was used to measure the beam characteristics such as symmetry, flatness and penumbra and these measurements were used to commission the radiochormic EBT3 film dosimetry system. The results of irradiated films were analysed using the radiochromic film QA Pro software 2016.ResultsThe measured film doses were analysed at two different colour channels (green and red) using two scanning geometries (i.e., upper or lower side of film facing the scanner light source) at two dose levels (10 and 40 Gy). The difference between the ionisation chamber and film results was found insignificant and within the acceptable range as per the World Health Organisation standard.ConclusionResults of the comparison between the ionisation chamber and film measurements show that our radiochormic EBT3 film dosimetry system is reliable and cost-effective in the output measurement of a linear accelerator. Our measurements confirm that our EBT3 film dosimetry agreed well with the ionisation chamber, and can be used as a re-validation tool for linear accelerator quality control.


2016 ◽  
Vol 119 ◽  
pp. S685
Author(s):  
S. Devic ◽  
S. Aldelaijan ◽  
F. Alzorkany ◽  
N. Tomic ◽  
J. Seuntjens ◽  
...  

2012 ◽  
Vol 39 (8) ◽  
pp. 4850-4857 ◽  
Author(s):  
Slobodan Devic ◽  
Nada Tomic ◽  
Saad Aldelaijan ◽  
Francois DeBlois ◽  
Jan Seuntjens ◽  
...  

2020 ◽  
Vol 76 (4) ◽  
pp. 375-384
Author(s):  
Haruhide Kunimoto ◽  
Hideharu Miura ◽  
Masanori Miyazawa ◽  
Masahiro Hayata ◽  
Takaaki Matsuura ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document