scholarly journals INFLUENCE OF STEEL MESH ON MAGNETIC PROXIMITY DETECTION SYSTEMS: AN EXPERIMENTAL STUDY

2020 ◽  
Vol 90 ◽  
pp. 89-97 ◽  
Author(s):  
Chenming Zhou ◽  
Bruce G. Whisner ◽  
Jacob L. Carr ◽  
Justin Srednicki
Author(s):  
Peter T. Bissert ◽  
Joseph P. DuCarme ◽  
Jacob L. Carr ◽  
Christopher C. Jobes ◽  
Jeffrey A. Yonkey

Since 1984, remote controlled continuous mining machines (CMM) have caused 40 crushing and pinning fatalities in the United States. Due to limited space in the underground environment and visibility needs, CMM operators typically work close to the machine which exposes them to the danger of being struck or pinned by it. Because of these fatalities, the Mine Safety and Health Administration (MSHA) has published a rule requiring proximity detection systems (PDSs) on all CMMs except for full-face machines. To test PDS performance, researchers at the National Institute for Occupational Safety and Health (NIOSH) conducted a series of field tests in underground coal mines throughout the United States on CMMs equipped with PDSs. The field tests collected data under a variety of conditions to evaluate the warning and shutdown zone performance of these systems. A baseline test condition was measured when the machine was operating in non-mining mode. Three additional conditions discussed in this paper include testing of the PDS while the machine was operating in mining mode, examining the possibility of parasitic coupling to the trailing cable, and examining the effects of the presence of a shuttle car. The results of this study indicate that the average warning and stop zones vary minimally between non-mining mode and trailing cable influence measurements, as well as between the mining mode and shuttle car presence tests. A majority of the measurements for warning and stop zones showed repeatability within +/− 5 inches (12.7 cm). Additionally, parasitic coupling to the trailing cable was not experienced during this field testing. However, these results show that the range of stop zone measurements varied by 4.7 ft on average and as much as 11.7 ft in different field sites. This is most likely due to individual preferences by operators during installation when the warning and stop zone distances are set. While a PDS should effectively stop a CMM when an operator gets too close to the machine, the large variations between field test measurements indicate that there is a wide variation of performance established during system installation.


2016 ◽  
Vol 121 ◽  
pp. 60-68 ◽  
Author(s):  
Han Li ◽  
Shengze Tian ◽  
Xinzhi Dang ◽  
Wancheng Yuan ◽  
Kai Wei

2012 ◽  
Vol 193-194 ◽  
pp. 847-851
Author(s):  
Yong Heng Yang ◽  
Den Rong Li ◽  
Yong Hui Liu ◽  
Ling Yun Li

In this paper, conducted a systematic study of thermal performance of steel mesh frame sandwich insulation board. The thermal performance of steel mesh frame sandwich insulation board was determined under different conditions. Proposed the insulation effect on oblique inserting wire in the steel mesh frame sandwich insulation board and provided the basis for engineering design and application.


Sign in / Sign up

Export Citation Format

Share Document