The effect of instrument parameters of x-ray fluorescence wavelength-dispersive spectrometer on the metrological characteristics of measurements

2019 ◽  
Vol 85 (2) ◽  
pp. 65-72
Author(s):  
N. Ya. Varkentin ◽  
O. A. Karavaeva
1984 ◽  
Vol 28 ◽  
pp. 195-202 ◽  
Author(s):  
Vladimir Kocman ◽  
Linda Foley ◽  
Stanley C. Woodger

A modern analytical laboratory of a large corporation manufacturing paper, construction materials and chemicals must be sufficiently diversified in methodology to provide accurate results in the shortest possible time. Among other techniques the implementation of an automated “menu” driven wavelength dispersive spectrometer allowed for the setting-up of a variety of quantitative X-ray fluorescence methods.


2020 ◽  
Vol 35 (12) ◽  
pp. 2935-2947
Author(s):  
Harpreet Singh Kainth ◽  
Deeksha Khandelwal

The measurements of X-ray emission lines in atomic decay to the L-shell of thallium compounds were performed using a laboratory source-based conventional wavelength dispersive spectrometer.


1988 ◽  
Vol 32 ◽  
pp. 83-87
Author(s):  
K. Omote ◽  
T. Arai

In the spectroscopic analysis of minor and trace elements by fluorescent X-rays, many improvements in the analytical performance of trace element measurements have been made. For the analysis of trace elements, the background intensity governs the analytical accuracy and the lowest detection limit in a sample. A comparison is made between experimental and theoretically calculated background X-ray intensities in a previous paper. It is based on the formula for scattered X-ray intensity, from the estimation of Thomson and Compton scattered X-rays. Also, the asymmetrical peak profiles at the base of the giant intensity peak are discussed and are clearly shown in the skirt part of K beta X-rays, e.g. , Ni-K beta or Fe-K beta X-rays. The purpose of this report is to investigate the intensity of background X-rays, using glass beads and powder samples of iron oxide and quartz, based on the previous fundamental studies and the overlapping correction procedure for cobalt determination in low-alloy and stainless steel.


1986 ◽  
Vol 60 (3) ◽  
pp. 268-270
Author(s):  
Yu. N. Burmistrenko ◽  
I. A. Tolokonnikov ◽  
O. N. Chernobrivets

2010 ◽  
Vol 17 (3) ◽  
pp. 400-408 ◽  
Author(s):  
J. Szlachetko ◽  
M. Cotte ◽  
J. Morse ◽  
M. Salomé ◽  
P. Jagodzinski ◽  
...  

2008 ◽  
Vol 14 (4) ◽  
pp. 306-314 ◽  
Author(s):  
Jorge Trincavelli ◽  
Silvina Limandri ◽  
Alejo Carreras ◽  
Rita Bonetto

A method for the experimental determination of the absolute efficiency of wavelength dispersive spectrometers was developed, based on the comparison of spectra measured with a wavelength dispersive system and with an energy dispersive spectrometer. The aim of studying this parameter arises because its knowledge is necessary to perform standardless analysis. A simple analytical expression was obtained for the efficiency curve for three crystals (TAP, PET, and LiF) of the spectrometer used, within an energy range from 0.77 to 10.83 keV. Although this expression is particular for the system used in this work, the method may be extended to other spectrometers and crystals for electron probe microanalysis and X-ray fluorescence.