scholarly journals Proximal Femoral Asymmetry in Japanese Patients before Total Hip Arthroplasty

10.29007/ms33 ◽  
2019 ◽  
Author(s):  
Maximilian C. M. Fischer ◽  
Kunihiko Tokunaga ◽  
Masashi Okamoto ◽  
Klaus Radermacher

Templating is an important and established step in the preoperative planning process of total hip arthroplasty (THA) in order to select the size and position of the implant. In severely arthritic cases, the unaffected contralateral side is sometimes used as a reference to reconstruct morphological parameters of the planned implantation (ipsilateral) side, for example the femoral offset, the leg length or the antetorsion. Recent studies have shown that a significant side-to-side asymmetry of important proximal femoral parameters already exists in healthy subjects questioning the validity of the contralateral side as a reference. However, if preoperative asymmetry is larger than asymmetry in healthy subjects, preoperative planning can still make use of the contralateral side to target a postoperative result within the range of physiological asymmetry. Therefore, the specific objective of this study was to quantify the preoperative side-to-side asymmetry of five important morphological parameters of the proximal femur. Significant side-to- side differences between the ipsilateral side and the contralateral side were detected for the antetorsion, the offset, the neck length and the femoral length. The antetorsion is significantly higher for the ipsilateral side whereas offset, neck length and femoral length are significantly smaller. Mean and maximum difference in antetorsion is almost twice as high for the THA patients in comparison to healthy subjects. The same trend can be observed for the femoral length, less pronounced also for the caput-collum-diaphyseal angle. The comparison of proximal femoral side-to-side differences for subjects before THA and healthy subjects leads to the conclusion that contralateral templating can be a reasonable basis for THA planning of severely arthritic hips if the contralateral side shows no signs of osteoarthritis or developmental dysplasia.

2019 ◽  
Vol 2019 ◽  
pp. 1-7 ◽  
Author(s):  
Y. Knafo ◽  
F. Houfani ◽  
B. Zaharia ◽  
F. Egrise ◽  
I. Clerc-Urmès ◽  
...  

Two-dimensional (2D) planning on standard radiographs for total hip arthroplasty may not be sufficiently accurate to predict implant sizing or restore leg length and femoral offset, whereas 3D planning avoids magnification and projection errors. Furthermore, weightbearing measures are not available with computed tomography (CT) and leg length and offset are rarely checked postoperatively using any imaging modality. Navigation can usually achieve a surgical plan precisely, but the choice of that plan remains key, which is best guided by preoperative planning. The study objectives were therefore to (1) evaluate the accuracy of stem/cup size prediction using dedicated 3D planning software based on biplanar radiographic imaging under weightbearing and (2) compare the preplanned leg length and femoral offset with the postoperative result. This single-centre, single-surgeon prospective study consisted of a cohort of 33 patients operated on over 24 months. The routine clinical workflow consisted of preoperative biplanar weightbearing imaging, 3D surgical planning, navigated surgery to execute the plan, and postoperative biplanar imaging to verify the radiological outcomes in 3D weightbearing. 3D planning was performed with the dedicated hipEOS® planning software to determine stem and cup size and position, plus 3D anatomical and functional parameters, in particular variations in leg length and femoral offset. Component size planning accuracy was 94% (31/33) within one size for the femoral stem and 100% (33/33) within one size for the acetabular cup. There were no significant differences between planned versus implanted femoral stem size or planned versus measured changes in leg length or offset. Cup size did differ significantly, tending towards implanting one size larger when there was a difference. Biplanar radiographs plus hipEOS planning software showed good reliability for predicting implant size, leg length, and femoral offset and postoperatively provided a check on the navigated surgery. Compared to previous studies, the predictive results were better than 2D planning on conventional radiography and equal to 3D planning on CT images, with lower radiation dose, and in the weightbearing position.


2021 ◽  
pp. 112070002110448
Author(s):  
Ryo Mitsutake ◽  
Hiromasa Tanino ◽  
Hiroshi Ito

Background: Dislocation continues to be a common complication following total hip arthroplasty (THA). Although previous studies of computed simulation analysis investigated the range of motion (ROM), it is unclear whether the ROM before impingement simulated using computed tomography-based 3-dimensional simulation analysis (simulated ROM) is related to dislocation after THA. It is also unclear what angles are required in computed simulation analyses for stable hips after THA. In this study, we compared the simulated ROM in patients with and without dislocation. Methods: 16 patients with posterior dislocation were compared with 48 matched patients without dislocation. Risk factors including preoperative bone morphology of the hip, implant position, change of femoral offset, change of leg length, anterior aspect of the greater trochanter (GTa) length, and anterior inferior iliac spine length were also compared. Results: The mean flexion angle, internal-rotation at 90° flexion (IR) angle, cup anteversion based on the anterior pelvic plane (APP), tilt-adjusted cup anteversion and GTa length were significantly different between patients with dislocation and patients without dislocation ( p = 0.033, 0.002, 0.010, 0.047, 0.046). A receiver-operating characteristic curve analysis suggested cutoff points for flexion angle, IR angle, cup anteversion based on the APP, tilt-adjusted cup anteversion and GTa length, of 114.5°, 45.5°, 19.5°, 12.0° and 15.3 mm. Conclusions: This study suggests that preoperative planning to achieve a larger simulated ROM, flexion angle and IR angle, may reduce the risk of posterior dislocation. This study also suggests that fine-tuning of cup anteversion and/or trimming of the overhanging GTa during preoperative planning may reduce the risk of posterior dislocation.


2020 ◽  
Author(s):  
Yinqiao Du ◽  
Jingyang Sun ◽  
Haiyang Ma ◽  
Sen Wang ◽  
Ming Ni ◽  
...  

Abstract Background: The purpose of this study was to explore that how to equalize the leg length in total hip arthroplasty (THA) with shortening subtrochanteric osteotomy (SSTO) or not for unilateral Crowe type IV developmental dysplasia of the hip (DDH) through the evaluation of the postoperative full-length anteroposterior radiographs. Methods: The postoperative radiographs of 60 patients with unilateral Crowe type IV DDH from July 2012 to May 2019 were retrospectively reviewed. These data included leg length, femoral length, height of center of rotation (COR) of hip, height of greater trochanter, and depth of the sleeve or cone. Patients with leg length discrepancy (LLD) < 10 mm were defined as the non-LLD group. Results: In the non LLD group (26 patients of SSTO and 22 of non-SSTO), the femoral length both SSTO and non-SSTO groups were significantly shorter on operated side, compared with the contralateral side, and the mean discrepancy in SSTO group was approximately equal to the mean length of SSTO. The mean height of COR of hip on operated sides both SSTO and non-SSTO groups were 13.2 mm, and the contralateral sides were 15.2 mm and 15.5 mm, respectively. The depth of the sleeve or cone between SSTO and non-SSTO groups were 21.7 mm and 30.6 mm, respectively. The depth of the sleeve or cone in SSTO group was negatively correlated with the length of SSTO. The height of the greater trochanter of the operated and contralateral sides were 5.3 mm and 16.6 mm in SSTO group, and those in the non-SSTO group were 13.2 mm and 17.2 mm. Conclusions: SSTO leaded to femoral shortening on the operated side for patients with unilateral Crowe type IV DDH. The position of sleeve or cone should be close to the apex of greater trochanter to compensate the lengh of SSTO.


2019 ◽  
pp. 112070001988292 ◽  
Author(s):  
Tyler E Calkins ◽  
Linda I Suleiman ◽  
Chris Culvern ◽  
Sulaiman Alazzawi ◽  
Gregory S Kazarian ◽  
...  

Introduction: Hip resurfacing arthroplasty (HRA) is an alternative to conventional total hip arthroplasty (THA) with potential advantages of preserving femoral bone stock and the ability to participate in higher impact activities. This study compares outcomes, satisfaction and preference in patients who underwent HRA in 1 hip and THA on the contralateral side. Methods: 62 Patients with an HRA in 1 hip and a contralateral THA were retrospectively identified at 3 centres, consisting of 38 males and 24 females with 53 patients (85.5%) undergoing HRA first. A survey regarding satisfaction and preference for each procedure and outcome scores were obtained. Results: Patients were younger (51.5 vs. 56.6 years, p = 0.002) and had longer follow-up on the HRA hip (11.0 vs. 6.0 years, p < 0.001). HRA was associated with larger increase in Harris Hip Score from preoperative to final follow-up (35.8 vs. 30.6, p = 0.035). 18 Patients (29.0%) preferred HRA, 19 (30.6%) preferred THA and 25 (40.3%) had no preference ( p = 0.844). When asked what they would choose if they could only have 1 surgery again, 41 (66.1%, p < 0.001) picked HRA. Overall satisfaction ( p = 0.504), willingness to live with their HRA versus THA for the rest of their life ( p = 0.295) and recommendation to others ( p = 0.097) were similar. Conclusions: Although HRA is associated with risks related to metal-on-metal bearings, it showed greater increase in patient-reported outcomes and a small subjective preference amongst patients who have undergone both conventional and resurfacing arthroplasty.


1998 ◽  
Vol 3 (6) ◽  
pp. 320-324 ◽  
Author(s):  
Nobuhiko Sugano ◽  
Kenji Ohzono ◽  
Takashi Nishii ◽  
Keiji Haraguchi ◽  
Takashi Sakai ◽  
...  