Minimally-invasive osteosynthesis of tibial plateau fractures

2000 ◽  
Vol 9 (5) ◽  
pp. 367-370 ◽  
Author(s):  
P. Benecke ◽  
C. Benecke ◽  
S. Christoph ◽  
HP. Bruch
2013 ◽  
Vol 99 (4) ◽  
pp. S267-S272 ◽  
Author(s):  
T. Vendeuvre ◽  
D. Babusiaux ◽  
C. Brèque ◽  
F. Khiami ◽  
V. Steiger ◽  
...  

Injury ◽  
2017 ◽  
Vol 48 (3) ◽  
pp. 784-788 ◽  
Author(s):  
Silvio Giannetti ◽  
Nicola Bizzotto ◽  
Andrea Stancati ◽  
Attilio Santucci

Author(s):  
Sivakumar Arumugam ◽  
Venkateshwara Arumugam ◽  
V. Raviraman

<p class="abstract"><strong>Background:</strong> Tibial plateau fractures constitute about 1% of all fractures and complex bicondylar fractures constitute 30% of all Tibial plateau fractures. Minimally Invasive Percutaneous Plate Osteosynthesis [MIPPO] is a method of biological fixation in which a plate is percutaneously inserted and fixed at a distance proximally and distally from the fracture site. By minimal exposure, this helps in the preservation of the essential fracture hematoma, minimal soft tissue dissection, avoidance of periosteal stripping and providing an adequate fixation. The objective of the study was to analyze the functional outcome of proximal Tibial fractures treated with MIPPO technique. The method of fixation shall be evaluated for the time period required for the patients to return to active work following surgery.</p><p class="abstract"><strong>Methods:</strong> In our study, all 18 patients with proximal Tibial fractures underwent definitive fixation by MIPPO technique. All our cases underwent initial stabilization as per the ATLS guidelines. Patients with closed Tibial plateau fractures associated with a tense haemarthrosis underwent aspiration of the joint under aseptic precautions. The limb was immobilized either in an above knee slab or through skeletal traction using a distal Tibial or calcaneal pin traction on a Bohler Braun splint until definitive fixation was carried out. In cases complicated with excessive swelling and blistering, definitive fixation was delayed until the swelling/ blistering subsided.<strong></strong></p><p class="abstract"><strong>Results:</strong> The post-operative results were designated as excellent, good, fair and poor according to pain, walking capacity, the range of motion and stability of the knee using Rasmussen’s grading system. In our study, the average functional knee score was 22.89. Rasmussen’s score does not consider articular congruity while assessing the functional outcome of the knee.</p><p class="abstract"><strong>Conclusions:</strong> MIPPO technique gives good to excellent results even in high energy Tibial condyle fractures [72.22% cases in our study]. Our patients were able to achieve a good functional range of movement, averaging 120 degrees. [Krettek et al – 124 degrees]. Those who were treated with early fixation and early mobilization were found to have a better functional outcome irrespective of the fracture type. No secondary bone grafting was required. </p>


2021 ◽  
Vol 11 (4) ◽  
pp. 82-86
Author(s):  
Wakil Ahmed ◽  
Shah M. Hafizur Rahman ◽  
Razib Ahmed ◽  
Maftun Ahmed ◽  
Abu Junaid Muhammad Musaddeque Reza

BMJ Open ◽  
2019 ◽  
Vol 9 (8) ◽  
pp. e026962
Author(s):  
Tanguy Vendeuvre ◽  
Olivier Monlezun ◽  
Claire Brandet ◽  
Pierre Ingrand ◽  
Isabelle Durand-Zaleski ◽  
...  

IntroductionFractures of the tibial plateau are in constant progression. They affect an elderly population suffering from a number of comorbidities, but also a young population increasingly practicing high-risk sports. The conventional open surgical technique used for tibial plateau fractures has several pitfalls: bone and skin devascularisation, increased risks of infection and functional rehabilitation difficulties. Since 2011, Poitiers University Hospital is offering to its patients a new minimally invasive technique for the reduction and stabilisation of tibial plateau fractures, named ‘tibial tuberoplasty’. This technique involves expansion of the tibial plateau through inflation using a kyphoplasty balloon, filling of the fracture cavity with cement and percutaneous screw fixation. We designed a study to evaluate the quality of fracture reduction offered by percutaneous tuberoplasty versus conventional open surgery for tibial plateau fracture and its impact on clinical outcome.Methods and analysisThis is a multicentre randomised controlled trial comparing two surgical techniques in the treatment of tibial plateau fractures. 140 patients with a Schatzker II or III tibial plateau fracture will be recruited in France. They will be randomised either in tibial tuberoplasty arm or in conventional surgery arm. The primary outcome is the postoperative radiological step-off reduction blindly measured on CT scan (within 48 hours post-op). Additional outcomes include other radiological endpoints, pain, functional abilities, quality of life assessment and health-economic endpoints. Outcomes assessment will be performed at baseline (before surgery), at day 0 (surgery), at 2, 21, 45 days, 3, 6, 12 and 24 months postsurgery.Ethics and disseminationThis study has been approved by the ethics committee Ile-De-France X and will be conducted in accordance with current Good Clinical Practice (GCP) guidelines, Declaration of Helsinki and standard operating procedures. The results will be disseminated through presentation at scientific conferences and publication in peer-reviewed journals.Trial registration numberClinicaltrial.gov:NCT03444779.


Sign in / Sign up

Export Citation Format

Share Document