scholarly journals Strengthening of the Panel Zone in Steel Moment Resisting Frames

2019 ◽  
Author(s):  
Masoud Abedini ◽  
Sudharshan N. Raman ◽  
Azrul A. Mutalib ◽  
Ebrahim Akhlaghi

Rehabilitation and retrofitting of structures designed in accordance to standard design codes is an essential practice in structural engineering and design. For steel structures, one of the challenges is to strengthen the panel zone as well as its analysis in moment-resisting frames. In this research, investigations were undertaken to analyze the influence of the panel zone in the response of structural frames through a computational approach using ETABS software. Moment-resisting frames of six stories were studied in supposition of real panel zone, different values of rigid zone factor, different thickness of double plates, and both double plates and rigid zone factor together. The frames were analyzed, designed and validated in accordance to Iranian steel building code. The results of drift values for six stories building models were plotted. After verifying and comparing the results, the findings showed that the rigidity lead to reduction in drifts of frames and also as a result, lower rigidity will be used for high rise building and higher rigidity will be used for low rise building. In frames with story drifts more than the permitted rate, where the frames are considered as the weaker panel zone area, the story drifts can be limited by strengthening the panel zone with double plates. It should be noted that higher thickness of double plates and higher rigidity of panel zone will result in enhancement of the non-linear deformation rates in beam elements. The resulting deformations of the panel zone due to this modification can have significant influence on the elastic and inelastic behavior of the frames.

1990 ◽  
Vol 17 (4) ◽  
pp. 659-667 ◽  
Author(s):  
R. G. Redwood ◽  
L. Lefki ◽  
G. Amar

New provisions of the CSA Standard for Steel Structures (CAN/CSA-S16.1-M89) dealing with detailing of moment resisting frames for seismic design are described and related to requirements of the National Building Code of Canada. The basis of the new requirements is outlined, and an example eight-storey frame is used to illustrate the impact of the provisions. Key words: design, structural engineering, steel, earthquakes, moment resisting frame, standards.


2017 ◽  
Vol 7 (6) ◽  
pp. 2139-2146 ◽  
Author(s):  
H. Veladi ◽  
H. Najafi

According to most valid Design Codes including the Iranian Seismic Design Code (Standard No. 2800), moment resisting frames in dual systems must have the ability of resisting the 25% of the total lateral load of the dual system independently. This study is conducted to investigate the implementation of this rule for dual steel structures with two types of steel braced frame. Also, its effect on the strength of the structure and the distribution of lateral load between the frames and the bracing system is evaluated. In order to investigate the effect of that rule, structural models with 5, 10 and 15 floors are modeled. Nonlinear static analysis is employed and results are discussed. Following the Standard No. 2008 seems to increase the structure’s lateral resistance and decrease the number of elements entered into the inelastic behavior stage. In general, the structure has a more desirable inelastic behavior.


Structures ◽  
2021 ◽  
Vol 32 ◽  
pp. 1646-1664
Author(s):  
Elena Elettore ◽  
Annarosa Lettieri ◽  
Fabio Freddi ◽  
Massimo Latour ◽  
Gianvittorio Rizzano

Sign in / Sign up

Export Citation Format

Share Document