Efficacy and Safety of XEN® Gel Stent and Post-operative Management in Patients With Open Angle Glaucoma

Author(s):  
2013 ◽  
Vol 5 (1) ◽  
pp. 75-80 ◽  
Author(s):  
Ashish Chander ◽  
H Kapoor ◽  
S Thomas

Purpose: To compare the efficacy and safety of bimatoprost (0.03 %) and travoprost (0.004 %) in patients with primary open angle glaucoma (POAG). Subjects and methods: Patients with POAG were randomized to receive either bimatoprost or travoprost once daily. Detailed ocular examination was done and intraocular pressure (IOP) was measured at 9.00 am, 1.00 pm and 4.00 pm at the baseline and at 1, 2, 4, 6 and 12 weeks of therapy. Results: A total of 31 patients were analysed. The patients were randomly divided into two groups (Bimatoprost group = 16; Travoprost group = 15). Both the groups had a statistically significant reduction from the baseline IOP at all follow up visits at 9.00 am, 1.00 pm and 4.00 pm. The mean IOP decreased from a baseline of 25 ± 2.32 mm Hg to 15.93 ± 1.79 mm Hg after 12 weeks in the bimatoprost group (p < 0.001), and from 24.2 ± 1.60 mm Hg to 16.53 ± 1.56 mm Hg in the travoprost group (p < 0.001). A better mean reduction of IOP was obtained with bimatoprost than with travoprost at the end of the study at 12 weeks (p = 0.03). Mild ocular redness was the commonest side effect in both the groups but was not significant in either group. Conclusion: Both drugs lowered IOP effectively but bimatoprost showed a greater reduction in the mean IOP than did travoprost at 12 weeks and both are safe for ocular use. Nepal J Ophthalmol 2013; 5(9):75-80 DOI: http://dx.doi.org/10.3126/nepjoph.v5i1.7831


2019 ◽  
Vol 6 (1) ◽  
Author(s):  
Omar Sadruddin ◽  
Leonard Pinchuk ◽  
Raymund Angeles ◽  
Paul Palmberg

AbstractTrabeculectomy remains the ‘gold standard’ intraocular pressure (IOP)-lowering procedure for moderate-to-severe glaucoma; however, this approach is associated with the need for substantial post-operative management. Micro-invasive glaucoma surgery (MIGS) procedures aim to reduce the need for intra- and post-operative management and provide a less invasive means of lowering IOP. Generally, MIGS procedures are associated with only modest reductions in IOP and are targeted at patients with mild-to-moderate glaucoma, highlighting an unmet need for a less invasive treatment of advanced and refractory glaucoma. The PRESERFLO® MicroShunt (formerly known as InnFocus MicroShunt) is an 8.5 mm-long (outer diameter 350 μm; internal lumen diameter 70 μm) glaucoma drainage device made from a highly biocompatible, bioinert material called poly (styrene-block-isobutylene-block-styrene), or SIBS. The lumen size is sufficiently small that at normal aqueous flow hypotony is avoided, but large enough to avoid being blocked by sloughed cells or pigment. The MicroShunt achieves the desired pressure range in the eye by draining aqueous humor from the anterior chamber to a bleb formed under the conjunctiva and Tenon’s capsule. The device is implanted ab externo with intraoperative Mitomycin C via a minimally invasive (relative to incisional surgery) surgical procedure, enabling precise control of placement without the need for gonioscopy, suture tension control, or suture lysis. The implantation procedure can be performed in combination with cataract surgery or as a standalone procedure. The MicroShunt received Conformité Européenne (CE) marking in 2012 and is intended for the reduction of IOP in eyes of patients with primary open-angle glaucoma in which IOP remains uncontrolled while on maximum tolerated medical therapy and/or in which glaucoma progression warrants surgery. Three clinical studies assessing the long-term safety and efficacy of the MicroShunt have been completed; a Phase 3 multicenter, randomized clinical study comparing the MicroShunt to primary trabeculectomy is underway. In preliminary studies, the MicroShunt effectively reduced IOP and use of glaucoma medications up to 3 years after implantation, with an acceptable safety profile. This article summarizes current literature on the unique properties of the MicroShunt, the preliminary efficacy and safety findings, and discusses its potential use as an alternative to trabeculectomy for glaucoma surgery.


2015 ◽  
Vol 43 (8) ◽  
pp. 768-771 ◽  
Author(s):  
Bogomil Voykov ◽  
Gunnar Blumenstock ◽  
Martin Alexander Leitritz ◽  
Spyridon Dimopoulos ◽  
Omar Alnahrawy

Sign in / Sign up

Export Citation Format

Share Document