Eye and Vision
Latest Publications


TOTAL DOCUMENTS

271
(FIVE YEARS 146)

H-INDEX

21
(FIVE YEARS 7)

Published By Springer (Biomed Central Ltd.)

2326-0254, 2326-0254

2022 ◽  
Vol 9 (1) ◽  
Author(s):  
Farhad Hafezi ◽  
Mohammed Hosny ◽  
Rohit Shetty ◽  
Boris Knyazer ◽  
Shihao Chen ◽  
...  

Abstract Background Infectious keratitis is a major cause of global blindness. We tested whether standalone photoactivated chromophore corneal cross-linking (PACK-CXL) may be an effective first-line treatment in early to moderate infectious keratitis, compared with standard antimicrobial treatment. Methods This is a randomized, controlled, multinational phase 3 clinical trial. Participants in five centers in Egypt, India, Iran, Israel, and China, aged ≥ 18 years, with infectious keratitis of presumed bacterial, fungal, or mixed origin, were randomly assigned (1:1) to PACK-CXL, or antimicrobial therapy. Outcomes measures included healing, defined as time to re-epithelialization of the corneal epithelial defect in the absence of inflammatory activity in the anterior chamber and clearance of stromal infiltrates. Treatment success was defined as the complete resolution of signs of infection. Results Between July 21, 2016, and March 4, 2020, participants were randomly assigned to receive PACK-CXL (n = 18) or antimicrobial therapy per American Academy of Ophthalmology (AAO) guidelines (n = 21). No participants were lost to follow-up. Four eyes were excluded from the epithelialization time analysis due to treatment failure: two in the antimicrobial therapy group, and two in the PACK-CXL group. Success rates were 88.9% (16/18 patients) in the PACK-CXL group and 90.5% (19/21 patients) in the medication group. There was no significant difference in time to complete corneal re-epithelialization (P = 0.828) between both treatment groups. Conclusions PACK-CXL may be an alternative to antimicrobial drugs for first-line and standalone treatment of early to moderate infectious keratitis of bacterial or fungal origin. Trial registration This trial is registered at ClinicalTrials.gov, trial registration number: NCT02717871


2022 ◽  
Vol 9 (1) ◽  
Author(s):  
Laura Gutierrez ◽  
Jane Sujuan Lim ◽  
Li Lian Foo ◽  
Wei Yan Yan Ng ◽  
Michelle Yip ◽  
...  

AbstractThe rise of artificial intelligence (AI) has brought breakthroughs in many areas of medicine. In ophthalmology, AI has delivered robust results in the screening and detection of diabetic retinopathy, age-related macular degeneration, glaucoma, and retinopathy of prematurity. Cataract management is another field that can benefit from greater AI application. Cataract  is the leading cause of reversible visual impairment with a rising global clinical burden. Improved diagnosis, monitoring, and surgical management are necessary to address this challenge. In addition, patients in large developing countries often suffer from limited access to tertiary care, a problem further exacerbated by the ongoing COVID-19 pandemic. AI on the other hand, can help transform cataract management by improving automation, efficacy and overcoming geographical barriers. First, AI can be applied as a telediagnostic platform to screen and diagnose patients with cataract using slit-lamp and fundus photographs. This utilizes a deep-learning, convolutional neural network (CNN) to detect and classify referable cataracts appropriately. Second, some of the latest intraocular lens formulas have used AI to enhance prediction accuracy, achieving superior postoperative refractive results compared to traditional formulas. Third, AI can be used to augment cataract surgical skill training by identifying different phases of cataract surgery on video and to optimize operating theater workflows by accurately predicting the duration of surgical procedures. Fourth, some AI CNN models are able to effectively predict the progression of posterior capsule opacification and eventual need for YAG laser capsulotomy. These advances in AI could transform cataract management and enable delivery of efficient ophthalmic services. The key challenges include ethical management of data, ensuring data security and privacy, demonstrating clinically acceptable performance, improving the generalizability of AI models across heterogeneous populations, and improving the trust of end-users.


2022 ◽  
Vol 9 (1) ◽  
Author(s):  
Rui Ning ◽  
Rongrong Gao ◽  
David P. Piñero ◽  
Jun Zhang ◽  
Qingyi Gao ◽  
...  

Abstract Background To evaluate the precision of corneal higher-order aberrations measurements after small incision lenticule extraction (SMILE) using the Sirius Scheimpflug-Placido topographer (CSO, Italy). Methods Seventy-five eyes from 75 postoperative subjects were included in this prospective study. Three consecutive corneal aberrometric measurements were obtained with the Scheimpflug-Placido topographer by two experienced operators to assess intra- and inter-observer reproducibility. The within-subject standard deviation (Sw), test-retest repeatability (TRT) and the intraclass correlation coefficient (ICC) were calculated. Results For intraobserver repeatability of anterior and total corneal aberrations, all ICCs were more than 0.922, except for trefoil (0.722 to 0.768). The ICCs of total root mean square (RMS), coma Z (3, ± 1), and spherical aberration Z (4, 0) were over 0.810 while higher-order RMS, trefoil Z (3, ± 3), and astigmatism II Z (4, ± 2) were below 0.634 for posterior corneal surface aberrations. All Sw values for all types of aberrations were equal to or below 0.07 μm. Regarding interobserver reproducibility, all TRT values were no more than 0.12 μm, 0.05 μm, and 0.11 μm for anterior, posterior, and total corneal aberrations, respectively. The ICC values ranged from 0.875 to 0.989, from 0.686 to 0.976 and over 0.834 for anterior, posterior, and total corneal aberrations, respectively. Conclusions The repeatability of measurements of anterior and total corneal aberrations with the Sirius system in corneas after SMILE surgery was high, except for trefoil. There was some variability in posterior corneal aberrometric measurements. High reproducibility of corneal aberrometric measurements was observed between measurements of both examiners, except for trefoil, with poor to moderate reproducibility.


2021 ◽  
Vol 8 (1) ◽  
Author(s):  
Miguel Faria Ribeiro
Keyword(s):  

2021 ◽  
Vol 8 (1) ◽  
Author(s):  
Jorge L. Alio ◽  
Francesco Versaci ◽  
Francesco D’Oria
Keyword(s):  

2021 ◽  
Vol 8 (1) ◽  
Author(s):  
Xinting Liu ◽  
Zhiyi Lin ◽  
Feifu Wang ◽  
Xiaoyi Peng ◽  
Wenwen He ◽  
...  

Abstract Background This study aims to examine interocular differences in the choroidal thickness and vascular density of the choriocapillaris in anisometropic myopes and to further explore the relationship between choroidal blood flow and myopia. Methods The sample comprised 44 participants with anisometropic myopia, aged 9 to 18 years, with normal best-corrected visual acuity. All participants underwent a series of examinations, including spherical equivalent refraction (SER) and axial length (AL), measured by a Lenstar optical biometer and optical coherence tomography angiography (OCTA) scanner. OCT measured the choroidal thickness, vascular density, and flow voids of the choriocapillaris, and a customized algorithm was implemented in MATLAB R2017a with the post-correction of AL. The choroidal thickness was measured at the fovea and 0.5, 1.0, 1.5, 2.0, 2.5, and 3.0 mm nasally, temporally, inferiorly, and superiorly to the fovea. The vascular density and the flow voids of the choriocapillaris were measured at a 0.6-mm-diameter central circle, and the 0.6–2.5 mm diameter circle in the nasal, temporal, inferior, and superior regions. Repeated-measured ANOVAs were used to analyze the interocular differences. Partial correlations with the K value and age adjustments were used to study the relationships between the choroidal thickness, the choriocapillaris vascular density and flow voids, the SER and AL. Results The choroidal thickness of the more myopic eyes was significantly thinner than less myopic eyes (P ≤ 0.001), and the flow voids in the more myopic eyes were more than less myopic eyes (P = 0.002). There was no significant difference in the vascular density of the choriocapillaris between the more and less myopic eyes (P = 0.525). However, when anisometropia was more than 1.50 D, the vascular density of choriocapillaris in the more myopic eyes was significantly less than the less myopic eyes (P = 0.026). The interocular difference of the choroidal thickness was significantly correlated with the interocular difference in SER and AL in the center, superior, and inferior regions but not in the nasal or temporal regions. The interocular differences of the vascular density and the flow voids of the choriocapillaris were not correlated with the interocular difference of SER and AL. Conclusions The choroidal thickness is thinner in the more myopic eyes. The flow void is increased, and the vascular density of the choriocapillaris is reduced in the more myopic eyes of children with anisometropia exceeding 1.50 D.


2021 ◽  
Vol 8 (1) ◽  
Author(s):  
António Queirós ◽  
Alejandro Cerviño ◽  
José Manuel González-Méijome

Abstract Purpose To measure axial and off-axis refraction patterns in myopic eyes with spectacle lenses correction and lens free emmetropes in young healthy subjects at different target distances from 2.00 m (0.50 D) to 0.20 m (5.00 D) in terms of sphere, astigmatism, and spherical equivalent refraction. Methods Refraction was measured at the center, 20 and 40 degrees from the line of sight both nasally and temporally in 15 emmetropic and 25 myopic young healthy subjects with an open field, binocular, infrared autorefractor (Grand Seiko WAM-5500, Hiroshima, Japan). Fixation target was a Maltese cross set at 2.00, 0.50, 0.33 and 0.20 m from the corneal plane. Changes in off-axis refraction with accommodation level were normalized with respect to distance axial values and compared between myopic eyes with spectacle lenses correction and lens free emmetropes. Results Off-axis refraction in myopic eyes with spectacle lenses correction was significantly more myopic in the temporal retina compared to lens free emmetropes except for the closest target distance. Relative off-axis refractive error changed significantly with accommodation when compared to axial refraction particularly in the myopic group. This change in the negative direction was due to changes in the spherical component of refraction that became more myopic relative to the center at the 0.20 m distance as the J0 component of astigmatism was significantly reduced in both emmetropes and myopes for the closest target. Conclusion Accommodation to very near targets (up to 0.20 m) makes the off-axis refraction of myopes wearing their spectacle correction similar to that of lens free emmetropes. A significant reduction in off-axis astigmatism was also observed for the 0.20 m distance.


2021 ◽  
Vol 8 (1) ◽  
Author(s):  
E. Valas Teuma ◽  
Frank A. Bucci ◽  
Raman Bedi ◽  
Gary Gray ◽  
Mark Packer

Abstract Background To evaluate the accuracy and safety of micro radial and arcuate keratotomy incisions constructed by a femtosecond laser system with a curved contact patient interface in porcine eyes. Methods Partial thickness micro radial and arcuate keratotomy incisions were constructed in porcine eyes with a femtosecond laser system and evaluated for precision of depth, quality, and consistency. Optical coherence tomography was used to determine the accuracy and precision of incision depth. Corneal endothelial safety was assessed by a fluorescent live/dead cell viability assay to demonstrate laser-induced endothelial cell loss. Quality was evaluated by ease of opening and examination of interfaces. Results In two micro radial incision groups, intended incision depths of 50% and 80% resulted in mean achieved depths of 50.01% and 77.69%, respectively. In three arcuate incision groups, intended incision depths of 80%, 600 μm or 100 μm residual uncut bed thickness resulted in mean achieved depths of 80.16%, 603.03 μm and residual bed of 115 μm, respectively. No loss of endothelial cell density occurred when the residual corneal bed was maintained at a minimum of 85–116 µm. The incisions were easy to open, and interfaces were smooth. Conclusions A femtosecond laser system with curved contact interface created precise and reproducible micro radial and arcuate keratotomy incisions. Accuracy and precision of the incision depth and preservation of endothelial cell density demonstrated the effectiveness and safety of the system.


2021 ◽  
Vol 8 (1) ◽  
Author(s):  
Ali Salimi ◽  
Harrison Watt ◽  
Paul Harasymowycz

Abstract Background The short- and medium-term outcomes of iStent have been extensively studied; however, only few studies have investigated its long-term outcomes. Here, we assessed the long-term efficacy and safety of two iStents with concomitant cataract surgery in glaucomatous eyes while also evaluating measures of disease stability using visual field and optical coherence tomography (OCT) of the optic nerve and the macula throughout 8 years of follow-up. Methods This longitudinal, single-center consecutive case series included glaucomatous eyes that underwent implantation of two first-generation trabecular micro-bypass stents (iStent) with concomitant cataract surgery. Eight-year efficacy outcomes included mean intraocular pressure (IOP) and medications, as well as surgical success. Eight-year safety outcomes included best-corrected visual acuity (BCVA), visual field mean deviation (VF-MD), cup-to-disc ratio (CDR), retinal nerve fiber layer (RNFL) thickness, ganglion cell-inner plexiform layer (GC-IPL) thickness, and adverse events. Results A total of 62 eyes with primary open-angle glaucoma (POAG) were included. At 8 years postoperative, IOP reduced by 26% from 19.2 ± 3.9 mmHg preoperatively to 14.2 ± 2.4 mmHg (P < 0.001), 91.1% of eyes achieved IOP ≤ 18 mmHg (vs. 51.6% preoperatively), 69.6% of eyes achieved IOP ≤ 15 mmHg (vs. 14.5% preoperatively), and 25% of eyes achieved IOP ≤ 12 mmHg (vs. 1.6% preoperatively). Medication use decreased by 17.9% from 2.8 ± 1.1 preoperatively to 2.3 ± 1.2 (P = 0.018). Surgical success was 90%, as six eyes underwent subsequent glaucoma surgeries. Safety measures of BCVA, CDR, RNFL thickness and GC-IPL thickness remained stable through 8 years postoperative. VF-MD remained stable until postoperative year 5 and subsequently progressed according to the natural history of glaucomatous disease. Conclusions Implantation of two iStents with concomitant cataract surgery is an effective and safe treatment option for surgery-naïve POAG eyes, evidenced by significant IOP and medication reductions, reasonable surgical success, and favorable safety outcomes, throughout the 8-year follow-up. Our data additionally supports the efficacy of this combined procedure in stabilizing or slowing disease progression.


2021 ◽  
Vol 8 (1) ◽  
Author(s):  
Yosai Mori ◽  
Tomofusa Yamauchi ◽  
Shota Tokuda ◽  
Keiichiro Minami ◽  
Hitoshi Tabuchi ◽  
...  

Abstract Background To examine the effectiveness of the use of machine learning for adapting an intraocular lens (IOL) power calculation for a patient group. Methods In this retrospective study, the clinical records of 1,611 eyes of 1,169 Japanese patients who received a single model of monofocal IOL (SN60WF, Alcon) at Miyata Eye Hospital were reviewed and analyzed. Using biometric metrics and postoperative refractions of 1211 eyes of 769 patients, constants of the SRK/T and Haigis formulas were optimized. The SRK/T formula was adapted using a support vector regressor. Prediction errors in the use of adapted formulas as well as the SRK/T, Haigis, Hill-RBF and Barrett Universal II formulas were evaluated with data from 395 eyes of 395 distinct patients. Mean prediction errors, median absolute errors, and percentages of eyes within ± 0.25 D, ± 0.50 D, and ± 1.00 D, and over + 0.50 D of errors were compared among formulas. Results The mean prediction errors in the use of the SRT/K and adapted formulas were smaller than the use of other formulas (P < 0.001). In the absolute errors, the Hill-RBF and adapted methods were better than others. The performance of the Barrett Universal II was not better than the others for the patient group. There were the least eyes with hyperopic refractive errors (16.5%) in the use of the adapted formula. Conclusions Adapting IOL power calculations using machine learning technology with data from a particular patient group was effective and promising.


Sign in / Sign up

Export Citation Format

Share Document