scholarly journals Effect of Extensive Use of Granite Countertops on the γ-Radiation Dose to Occupants of the New Buildings of King Abdulaziz University

Author(s):  
Mohammed Sami Tayeb ◽  
Abdulraheem Abdulrahman Kinsara

Exposure dose due to γ-radiation was measured in the new buildings of King Abdulaziz University using an advanced car-borne monitoring system to evaluate the effect of the extensive use of granites on the exposure dose rate to occupants. The measurements were conducted inside and outside the new buildings. For comparison, measurements inside the old buildings of limited granite use were conducted. The results indicated that the average exposure dose rate in the corridors of granite countertops was 0.115 μSv/h compared to 0.093 μSv/h in corridors of marble floors in the old buildings. About 4.2% increase in the annual effective dose due granite use was estimated. A maximum excess fatal cancer risk to an individual working in the new buildings due to exposure to excess γ-radiation from granite countertops was estimated by 1.4x10-6. The obtained results are discussed in detail and some conclusions are drawn.

2015 ◽  
Vol 11 (3) ◽  
pp. 1-9
Author(s):  
Ugochukwu Okoro ◽  
Ijeoma Dike ◽  
Chidiezie Chineke ◽  
Christiana Godwin ◽  
Chiamaka Chukwunyere

2012 ◽  
Vol 55 (3) ◽  
pp. 341-344
Author(s):  
N. F. Demchenko ◽  
R. N. Minvaliev ◽  
V. I. Shipilov ◽  
I. A. Kharitonov

1975 ◽  
Vol 18 (10) ◽  
pp. 1535-1536
Author(s):  
V. S. Gorev ◽  
V. A. Kozhemyakin ◽  
M. D. Firsov ◽  
V. A. Fomenko ◽  
A. L. Kholodkov ◽  
...  

2017 ◽  
Vol 9 (12) ◽  
pp. 19
Author(s):  
Nursama Heru Apriantoro ◽  
Muzilman Muslim ◽  
Dadong Iskandar ◽  
. Purwantiningsih ◽  
Witri Mulyani ◽  
...  

Terrestrial gamma radiation dose (TGRD) rate measurement has been conducted around downtown region of Central Jakarta Indonesia. The real time count data was taken 1 m above the ground in eight sub district locations by using a portable gamma Surveymeter of Exploranium GR-135 Plus Model. The reading position was detemined using  Garmin GPSMAP 62s. The average value of TGRD rate of  (47.76 ± 18.24) nSv h-1 ranged from 6.40 nSv h-1 to 120.90 nSv-1, it is higher than Indonesia. The annual effective dose rate of 0.058 mSv. Its  contributes to fatal cancer risk of about  3.22 x 10-5 per year for each individual in Central Jakarta. For the subdistrict TGRD rate value was variated, however all the result is not high enough to cause for alarm.


Sign in / Sign up

Export Citation Format

Share Document