A multicenter, open-label, controlled trial on acceptance, convenience, and complications of rechargeable internal pulse generators for deep brain stimulation: the Multi Recharge Trial

2020 ◽  
Vol 133 (3) ◽  
pp. 821-829 ◽  
Author(s):  
Martin Jakobs ◽  
Ann-Kristin Helmers ◽  
Michael Synowitz ◽  
Philipp J. Slotty ◽  
Judith M. Anthofer ◽  
...  

OBJECTIVERechargeable neurostimulators for deep brain stimulation have been available since 2008, promising longer battery life and fewer replacement surgeries compared to non-rechargeable systems. Long-term data on how recharging affects movement disorder patients are sparse. This is the first multicenter, patient-focused, industry-independent study on rechargeable neurostimulators.METHODSFour neurosurgical centers sent a questionnaire to all adult movement disorder patients with a rechargeable neurostimulator implanted at the time of the trial. The primary endpoint was the convenience of the recharging process rated on an ordinal scale from “very hard” (1) to “very easy” (5). Secondary endpoints were charge burden (time spent per week on recharging), user confidence, and complication rates. Endpoints were compared for several subgroups.RESULTSDatasets of 195 movement disorder patients (66.1% of sent questionnaires) with Parkinson’s disease (PD), tremor, or dystonia were returned and included in the analysis. Patients had a mean age of 61.3 years and the device was implanted for a mean of 40.3 months. The overall convenience of recharging was rated as “easy” (4). The mean charge burden was 122 min/wk and showed a positive correlation with duration of therapy; 93.8% of users felt confident recharging the device. The rate of surgical revisions was 4.1%, and the infection rate was 2.1%. Failed recharges occurred in 8.7% of patients, and 3.6% of patients experienced an interruption of therapy because of a failed recharge. Convenience ratings by PD patients were significantly worse than ratings by dystonia patients. Caregivers recharged the device for the patient in 12.3% of cases. Patients who switched from a non-rechargeable to a rechargeable neurostimulator found recharging to be significantly less convenient at a higher charge burden than did patients whose primary implant was rechargeable. Age did not have a significant impact on any endpoint.CONCLUSIONSOverall, patients with movement disorders rated recharging as easy, with low complication rates and acceptable charge burden.

2010 ◽  
Vol 113 (3) ◽  
pp. 634-638 ◽  
Author(s):  
Diana Apetauerova ◽  
Clemens M. Schirmer ◽  
Jay L. Shils ◽  
Janet Zani ◽  
Jeffrey E. Arle

The authors report the cases of 2 young male patients (aged 16 and 26 years) with dystonic cerebral palsy of unknown origin, who developed status dystonicus, an acute and persistent combination of generalized dystonia and chorea. Both patients developed status dystonicus after undergoing general anesthesia, and in 1 case, after administration of metoclopramide. In attempting to control this acute hyperkinetic movement disorder, multiple medication trials failed in both cases and patients required prolonged intubation and sedation with propofol. Bilateral deep brain stimulation of the globus pallidus internus (4 and 2 months after the onset of symptoms in the first and second case, respectively) produced immediate resolution of the hyperkinetic movement disorder in each case. Deep brain stimulation provided persistent suppression of the dystonic movement potential after a follow-up of 30 and 34 months, respectively, as demonstrated by the reemergence of severe dystonia during the end of battery life of the implantable pulse generators that was readily controlled by exchange of the generators in each case.


Neurology ◽  
2012 ◽  
Vol 78 (Meeting Abstracts 1) ◽  
pp. P02.231-P02.231
Author(s):  
J. P. Azulay ◽  
C. Breffel Courbon ◽  
L. Defebvre ◽  
T. Witjas ◽  
C. Tranchant ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document