Comparison of CD HORIZON SPIRE spinous process plate stabilization and pedicle screw fixation after anterior lumbar interbody fusion

2006 ◽  
Vol 4 (2) ◽  
pp. 132-136 ◽  
Author(s):  
Jeremy C. Wang ◽  
Regis W. Haid ◽  
Jay S. Miller ◽  
James C. Robinson

Object The authors present the early clinical results obtained in patients who underwent SPIRE spinous process plate fixation following anterior lumbar interbody fusion (ALIF). Methods Between May 2003 and January 2005, 32 patients underwent titanium cage and bone morphogenetic protein–augmented ALIF and subsequent SPIRE (21 cases) or bilateral pedicle screw (BPS; 11 cases) fixation. Pedicle screws were implanted using either the open approach (three cases) or using a tubular retractor (eight cases). Patients’ charts were reviewed for operative time, estimated blood loss (EBL), hospital length of stay (LOS), and evidence of pseudarthrosis or hardware failure. In SPIRE plate–treated patients, the median EBL (75 ml) was lower than in BPS-treated patients (open BPS [150 ml]; tubular BPS [125 ml]). The median operative time in SPIRE plate–treated patients was also shorter (164 minutes compared with 239 and 250 minutes in the open and tubular BPS, respectively). The median LOS was 3 days for both the SPIRE and tubular BPS groups, but 4 days in the open BPS group. There were no instances of major surgery-induced complication, pseudarthrosis, or hardware failure during mean follow-up periods of 5.5, 7.2, and 4.9 months in the SPIRE, open PS, and tubular BPS groups, respectively. Conclusions The SPIRE plate is easy to implant and is associated with minimal operative risk. Compared with BPS/rod constructs, SPIRE plate fixation leads to less EBL and shorter operative time, without an increase in the rate of pseudarthrosis. Hospital LOS was also shorter in SPIRE plate–treated patients, which is consistent with the goals of minimal access spinal technologies.

2019 ◽  
Vol 9 (7) ◽  
pp. 692-696
Author(s):  
Chang-Hoon Jeon ◽  
Han-Dong Lee ◽  
Nam-Su Chung

Study Design: Retrospective case-control study. Objectives: To investigate whether mechanical bowel preparation (MBP) improve surgical performance and decrease operative complications in anterior lumbar interbody fusion (ALIF). Methods: This study involved a retrospective analysis of 48 consecutive patients who underwent ALIF with MBP and a control cohort of 50 consecutive patients who underwent the same surgeries without MBP. The quality of each surgical procedure, operative time, estimated blood loss (EBL), intraoperative complications, changes in vital signs and patient symptoms on the day of surgery, and bowel function postoperatively were also compared between the procedures. Results: Baseline demographic characteristics were similar between the 2 groups (all Ps > .05). The quality of each procedure, operative time, EBL, intraoperative complications, and changes in body temperature and heart rate were not different between the groups (all Ps > .05). The MBP group showed more headache, tiredness, thirst, and abdominal discomfort (all Ps < .001) and decrease of the systolic blood pressure ( P = .041) on the day of surgery. The return of bowel movement was not different between the groups ( P = .278). Conclusions: Given the similar surgical result with the substantial patient discomfort, MBP can be omitted in ALIF.


2010 ◽  
Vol 12 (4) ◽  
pp. 372-380 ◽  
Author(s):  
Dean G. Karahalios ◽  
Taro Kaibara ◽  
Randall W. Porter ◽  
Udaya K. Kakarla ◽  
Phillip M. Reyes ◽  
...  

Object An interspinous anchor (ISA) provides fixation to the lumbar spine to facilitate fusion. The biomechanical stability provided by the Aspen ISA was studied in applications utilizing an anterior lumbar interbody fusion (ALIF) construct. Methods Seven human cadaveric L3–S1 specimens were tested in the following states: 1) intact; 2) after placing an ISA at L4–5; 3) after ALIF with an ISA; 4) after ALIF with an ISA and anterior screw/plate fixation system; 5) after removing the ISA (ALIF with plate only); 6) after removing the plate (ALIF only); and 7) after applying bilateral pedicle screws and rods. Pure moments (7.5 Nm maximum) were applied in flexion and extension, lateral bending, and axial rotation while recording angular motion optoelectronically. Changes in angulation as well as foraminal height were also measured. Results All instrumentation variances except ALIF alone reduced angular range of motion (ROM) significantly from normal in all directions of loading. The ISA was most effective in limiting flexion and extension (25% of normal) and less effective in reducing lateral bending (71% of normal) and axial rotation (71% of normal). Overall, ALIF with an ISA provided stability that was statistically equivalent to ALIF with bilateral pedicle screws and rods. An ISA-augmented ALIF allowed less ROM than plate-augmented ALIF during flexion, extension, and lateral bending. Use of the ISA resulted in flexion at the index level, with a resultant increase in foraminal height. Compensatory extension at the adjacent levels prevented any significant change in overall sagittal balance. Conclusions When used with ALIF at L4–5, the ISA provides immediate rigid immobilization of the lumbar spine, allowing equivalent ROM to that of a pedicle screw/rod system, and smaller ROM than an anterior plate. When used with ALIF, the ISA may offer an alternative to anterior plate fixation or bilateral pedicle screw/rod constructs.


2004 ◽  
Vol 4 (5) ◽  
pp. S36-S37
Author(s):  
Ensor Transfeldt ◽  
Esat Kiter ◽  
Timothy Garvey ◽  
Amir Mehbod ◽  
Manuel Pinto

2007 ◽  
Vol 6 (3) ◽  
pp. 267-271 ◽  
Author(s):  
Tann A. Nichols ◽  
Brenda K. Yantzer ◽  
Suzanne Alameda ◽  
Wesley M. Johnson ◽  
Bernard H. Guiot

Object Posterior pedicle screw (PS) instrumentation is often used to augment anterior lumbar interbody fusion (ALIF) but at the cost of an increase in the morbidity rate due to the second approach and screw placement. If anterior plates were found to be biomechanically equivalent to PS fixation (PSF) after ALIF, then this second approach could be avoided without decreasing vertebral stability. Methods Eight cadaveric L5–S1 spinal segments were tested under four conditions: intact, following anterior discectomy and interbody spacer placement, after placement of an anterior plate, and following PSF. The elastic zone and stiffness were calculated for axial compression, flexion/extension, lateral bending, and torsion. Neither anterior plate stabilization nor PSF showed significant intergroup differences in stiffness or the elastic zone. Both exhibited greater stiffness in flexion than the intact specimens (p < 0.001). Pedicle screw fixation was associated with a decreased elastic zone in lateral bending compared with the intact specimen (p < 0.04). Conclusions Anterior plate fixation is biomechanically similar to PSF following ALIF. Surgeons may wish to use anterior plates in place of PSs to avoid the need for a posterior procedure. This may lead to a decrease in operative morbidity and improved overall outcomes.


Sign in / Sign up

Export Citation Format

Share Document