Efficient and robust 3D CT image reconstruction based on total generalized variation regularization using the alternating direction method

2015 ◽  
Vol 23 (6) ◽  
pp. 683-699 ◽  
Author(s):  
Jianlin Chen ◽  
Linyuan Wang ◽  
Bin Yan ◽  
Hanming Zhang ◽  
Genyang Cheng
2013 ◽  
Vol 2013 ◽  
pp. 1-7 ◽  
Author(s):  
Linyuan Wang ◽  
Ailong Cai ◽  
Hanming Zhang ◽  
Bin Yan ◽  
Lei Li ◽  
...  

With the development of compressive sensing theory, image reconstruction from few-view projections has received considerable research attentions in the field of computed tomography (CT). Total-variation- (TV-) based CT image reconstruction has been shown to be experimentally capable of producing accurate reconstructions from sparse-view data. In this study, a distributed reconstruction algorithm based on TV minimization has been developed. This algorithm is very simple as it uses the alternating direction method. The proposed method can accelerate the alternating direction total variation minimization (ADTVM) algorithm without losing accuracy.


2014 ◽  
Vol 511-512 ◽  
pp. 417-420
Author(s):  
Lin Yuan Wang ◽  
Ai Long Cai ◽  
Bin Yan ◽  
Lei Li ◽  
Han Ming Zhang ◽  
...  

Total variation (TV)-based CT image reconstruction has been shown to be experimentally capable of producing accurate reconstructions from sparse-view data. In this study, an inexact distributed reconstruction algorithm based on TV minimization has been developed. The algorithm is relatively simple as it uses the inexact alternating direction method, which involves linearization and proximal points techniques. The outstanding acceleration factor is achieved as the algorithm distributes the data and computation to individual nodes. Experimental results demonstrate that the proposed method can accelerate the alternating direction total variation minimization (ADTVM) algorithm with very little accuracy loss.


2018 ◽  
Vol 37 (6) ◽  
pp. 1498-1510 ◽  
Author(s):  
Xuehang Zheng ◽  
Saiprasad Ravishankar ◽  
Yong Long ◽  
Jeffrey A. Fessler

2019 ◽  
Vol 6 (4) ◽  
pp. 111 ◽  
Author(s):  
Huidong Xie ◽  
Hongming Shan ◽  
Ge Wang

X-ray computed tomography (CT) is widely used in clinical practice. The involved ionizing X-ray radiation, however, could increase cancer risk. Hence, the reduction of the radiation dose has been an important topic in recent years. Few-view CT image reconstruction is one of the main ways to minimize radiation dose and potentially allow a stationary CT architecture. In this paper, we propose a deep encoder-decoder adversarial reconstruction (DEAR) network for 3D CT image reconstruction from few-view data. Since the artifacts caused by few-view reconstruction appear in 3D instead of 2D geometry, a 3D deep network has a great potential for improving the image quality in a data driven fashion. More specifically, our proposed DEAR-3D network aims at reconstructing 3D volume directly from clinical 3D spiral cone-beam image data. DEAR is validated on a publicly available abdominal CT dataset prepared and authorized by Mayo Clinic. Compared with other 2D deep learning methods, the proposed DEAR-3D network can utilize 3D information to produce promising reconstruction results.


Sign in / Sign up

Export Citation Format

Share Document