scholarly journals Absolute Change in High Sensitivity Cardiac Troponin I for Three Hours is Useful for Diagnosing Acute Myocardial Infarction in the Emergency Department: How to Get to Best Benefit From HS-Troponins in Clinical Practice?

2020 ◽  
Vol 40 (6) ◽  
pp. 488-489
Author(s):  
Fabien Huet ◽  
Anne Marie Dupuy ◽  
Jean Paul Cristol ◽  
François Roubille
2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
J Boeddinghaus ◽  
T Nestelberger ◽  
R Twerenbold ◽  
L Koechlin ◽  
D Wussler ◽  
...  

Abstract Background Lately, the novel high-sensitivity cardiac troponin I (hs-cTnI) Access assay was developed. Its clinical performance in patients presenting with chest pain to the emergency department (ED) is unknown. Purpose To clinically validate the novel hs-cTnI-Access assay and to derive and validate an assay specific 0/1h-algorithm accordingly to the European Society of Cardiology (ESC) recommendations. Methods In a prospective international multicentre study we enrolled patients presenting to the emergency department with symptoms suggestive of acute myocardial infarction (AMI). Final diagnoses were centrally adjudicated by two independent cardiologists including all clinical information including cardiac imaging twice: first, using serial hs-cTnT (Elecsys, primary analysis) and second, using hs-cTnI (Architect, secondary analysis) measurements in addition to the clinically used (hs)-cTn. Hs-cTnI-Access was measured at presentation and at 1h. Primary objective was a direct comparison of diagnostic accuracy as quantified by the area under the receiver-operating-characteristic curve (AUC) of hs-cTnI-Access versus the two established hs-cTn assays (hs-cTnT-Elecsys, hs-cTnI-Architect). Secondary objectives included the derivation and internal validation of an hs-cTnI-Access specific 0/1h-algorithm. Results AMI was the adjudicated final diagnosis in 243/1579 (15.4%) patients. The AUC at presentation for hs-cTnI-Access was 0.95 (95% CI, 0.94–0.96), significantly higher as hs-cTnI-Architect (0.92 [95% CI, 0.91–0.94; p<0.001]), and comparable to hs-cTnT-Elecsys (0.94 [95% CI, 0.93–0.95; p=0.12]) Applying the derived hs-cTnI-Access 0/1h-algorithm (derivation cohort n=686) to the internal validation cohort (n=680), 60% of patients were ruled-out (sensitivity 98.9% [95% CI, 94.3–99.8]), and 15% of patients were ruled-in (specificity 95.9% [95% CI, 94.0–97.2]). Patients ruled-out by the 0/1h-algorithm had a survival rate of of 100% after 30-days and 98.4% after two years of follow up. Findings were confirmed in the secondary analyses using the adjudication including serial measurements of hs-cTnI (Architect). Performance of the 0/1h-algorithm Conclusions Diagnostic accuracy of the novel hs-cTnI-Access assay is excellent and at least comparable to the two established hs-cTn assays. The assay-specific 0/1h-algorithm allows a safe rule-out and accurate rule-in of MI in about 75% of patients within 1-hour after presentation to the ED. Survival of patients ruled-out by the 0/1h-algorithm was very high. Acknowledgement/Funding Swiss National Science Foundation, the Swiss Heart Foundation, the KTI, the European Union, the Stiftung für kardiovaskuläre Forschung Basel


Circulation ◽  
2017 ◽  
Vol 135 (17) ◽  
pp. 1597-1611 ◽  
Author(s):  
Jasper Boeddinghaus ◽  
Thomas Nestelberger ◽  
Raphael Twerenbold ◽  
Karin Wildi ◽  
Patrick Badertscher ◽  
...  

2016 ◽  
Vol 171 (1) ◽  
pp. 92-102.e5 ◽  
Author(s):  
Cedric Jaeger ◽  
Karin Wildi ◽  
Raphael Twerenbold ◽  
Tobias Reichlin ◽  
Maria Rubini Gimenez ◽  
...  