scholarly journals Predicting 30-Day and 180-Day Mortality in Elderly Proximal Hip Fracture Patients: Evaluation of 4 Risk Prediction Scores at a Level I Trauma Center

Diagnostics ◽  
2021 ◽  
Vol 11 (3) ◽  
pp. 497
Author(s):  
Arastoo Nia ◽  
Domenik Popp ◽  
Georg Thalmann ◽  
Fabian Greiner ◽  
Natasa Jeremic ◽  
...  

This study evaluated the use of risk prediction models in estimating short- and mid-term mortality following proximal hip fracture in an elderly Austrian population. Data from 1101 patients who sustained a proximal hip fracture were retrospectively analyzed and applied to four models of interest: Physiological and Operative Severity Score for the enUmeration of Mortality and Morbidity (POSSUM), Charlson Comorbidity Index, Portsmouth-POSSUM and the American College of Surgeons National Surgical Quality Improvement Program (ACS-NSQIP®) Risk Score. The performance of these models according to the risk prediction of short- and mid-term mortality was assessed with a receiver operating characteristic curve (ROC). The median age of participants was 83 years, and 69% were women. Six point one percent of patients were deceased by 30 days and 15.2% by 180 days postoperatively. There was no significant difference between the models; the ACS-NSQIP had the largest area under the receiver operating characteristic curve for within 30-day and 180-day mortality. Age, male gender, and hemoglobin (Hb) levels at admission <12.0 g/dL were identified as significant risk factors associated with a shorter time to death at 30 and 180 days postoperative (p < 0.001). Among the four scores, the ACS-NSQIP score could be best-suited clinically and showed the highest discriminative performance, although it was not specifically designed for the hip fracture population.

2019 ◽  
Vol 30 (7-8) ◽  
pp. 221-228
Author(s):  
Shahab Hajibandeh ◽  
Shahin Hajibandeh ◽  
Nicholas Hobbs ◽  
Jigar Shah ◽  
Matthew Harris ◽  
...  

Aims To investigate whether an intraperitoneal contamination index (ICI) derived from combined preoperative levels of C-reactive protein, lactate, neutrophils, lymphocytes and albumin could predict the extent of intraperitoneal contamination in patients with acute abdominal pathology. Methods Patients aged over 18 who underwent emergency laparotomy for acute abdominal pathology between January 2014 and October 2018 were randomly divided into primary and validation cohorts. The proposed intraperitoneal contamination index was calculated for each patient in each cohort. Receiver operating characteristic curve analysis was performed to determine discrimination of the index and cut-off values of preoperative intraperitoneal contamination index that could predict the extent of intraperitoneal contamination. Results Overall, 468 patients were included in this study; 234 in the primary cohort and 234 in the validation cohort. The analyses identified intraperitoneal contamination index of 24.77 and 24.32 as cut-off values for purulent contamination in the primary cohort (area under the curve (AUC): 0.73, P < 0.0001; sensitivity: 84%, specificity: 60%) and validation cohort (AUC: 0.83, P < 0.0001; sensitivity: 91%, specificity: 69%), respectively. Receiver operating characteristic curve analysis also identified intraperitoneal contamination index of 33.70 and 33.41 as cut-off values for feculent contamination in the primary cohort (AUC: 0.78, P < 0.0001; sensitivity: 87%, specificity: 64%) and validation cohort (AUC: 0.79, P < 0.0001; sensitivity: 86%, specificity: 73%), respectively. Conclusions As a predictive measure which is derived purely from biomarkers, intraperitoneal contamination index may be accurate enough to predict the extent of intraperitoneal contamination in patients with acute abdominal pathology and to facilitate decision-making together with clinical and radiological findings.


2021 ◽  
pp. 096228022199595
Author(s):  
Yalda Zarnegarnia ◽  
Shari Messinger

Receiver operating characteristic curves are widely used in medical research to illustrate biomarker performance in binary classification, particularly with respect to disease or health status. Study designs that include related subjects, such as siblings, usually have common environmental or genetic factors giving rise to correlated biomarker data. The design could be used to improve detection of biomarkers informative of increased risk, allowing initiation of treatment to stop or slow disease progression. Available methods for receiver operating characteristic construction do not take advantage of correlation inherent in this design to improve biomarker performance. This paper will briefly review some developed methods for receiver operating characteristic curve estimation in settings with correlated data from case–control designs and will discuss the limitations of current methods for analyzing correlated familial paired data. An alternative approach using conditional receiver operating characteristic curves will be demonstrated. The proposed approach will use information about correlation among biomarker values, producing conditional receiver operating characteristic curves that evaluate the ability of a biomarker to discriminate between affected and unaffected subjects in a familial paired design.


Sign in / Sign up

Export Citation Format

Share Document