scholarly journals Hemolytic Performance in Two Generations of the Sputnik Left Ventricular Assist Device: A Combined Numerical and Experimental Study

2022 ◽  
Vol 13 (1) ◽  
pp. 7
Author(s):  
Alexandra N. Romanova ◽  
Alexander A. Pugovkin ◽  
Maxim V. Denisov ◽  
Ivan A. Ephimov ◽  
Dmitry V. Gusev ◽  
...  

Background: Currently, left ventricular assist devices (LVADs) are a successful surgical treatment for patients with end-stage heart failure on the waiting list or with contraindicated heart transplantation. In Russia, Sputnik 1 LVAD was also successfully introduced into clinical practice as a bridge-to-transplant and a destination therapy device. Development of Sputnik 2 LVAD was aimed at miniaturization to reduce invasiveness, optimize hemocompatibility, and improve versatility for patients of various sizes. Methods: We compared hemolysis level in flow path of the Sputnik LVADs and investigated design aspects influencing other types of blood damage, using predictions of computational fluid dynamics (CFD) and experimental assessment. The investigated operating point was a flow rate of 5 L/min and a pressure head of 100 mm Hg at an impeller rotational speed of 9100 min−1. Results: Mean hemolysis indices predicted with CFD were 0.0090% in the Sputnik 1 and 0.0023% in the Sputnik 2. Averaged values of normalized index of hemolysis obtained experimentally for the Sputnik 1 and the Sputnik 2 were 0.011 ± 0.003 g/100 L and 0.004 ± 0.002 g/100 L, respectively. Conclusions: Obtained results indicate obvious improvements in hemocompatibility and sufficiently satisfy the determined miniaturization aim for the Sputnik 2 LVAD development.

Author(s):  
Timothy J Fendler ◽  
Michael E Nassif ◽  
Kevin F Kennedy ◽  
John A Spertus ◽  
Shane J LaRue ◽  
...  

Background: Left ventricular assist device (LVAD) therapy can improve survival and quality of life in advanced heart failure (HF), but some patients may still do poorly after LVAD. Understanding the likelihood of experiencing poorer outcomes after LVAD can better inform patients and calibrate their expectations. Methods: We analyzed patients receiving LVAD therapy from January 2012 to October 2013 at a single, high-volume, high-acuity center. We defined a poor global outcome at 1 year after LVAD as the occurrence of death, disabling stroke (precluding transplant), poor patient-reported health status (most recent KCCQ at 3, 6, or 12 months < 45, corresponding to NYHA class IV), or recurrent HF (≥2 HF readmissions post-implant). We compared characteristics of those with and without poor global outcome. Results: Among 164 LVAD recipients who had 1-year outcomes data, mean age was 56, 76.7% were white, 20.9% were female, and 85.9% were INTERMACS Profile 1 or 2 (cardiogenic shock or declining despite inotropes). Poor global outcome occurred in 58 (35.4%) patients at 1 year, of whom 37 (63.8%) died, 17 (29.3%) had a most recent KCCQ score < 45, 3 (5.2%) had ≥2 HF readmissions, and 1 (1.7%) had a disabling stroke (Figure). Eight of the patients who died also experienced one of the three other poor outcomes prior to death. Patients who experienced a poor global outcome were more likely to be designated for destination therapy (46.4% vs. 23.6%, p=0.01) than bridge to transplant, have longer index admissions (median [IQR]: 39 [24, 57] days vs. 25 [18, 35] days, p=0.003), and have major GI bleeding (44.2% vs. 27.7%, p=0.056), and were less likely to undergo LVAD exchange (0% vs. 12.3%, p=0.004). Conclusion: In this large, single-center study assessing global outcome after LVAD implantation, we found that about a third of all patients had experienced a poor global outcome at 1 year. While LVAD therapy remains life-saving and the standard of care for many patients with advanced heart failure, these findings could help guide discussions with eligible patients and families. Future work should compare patients’ pre-LVAD expectations with likely outcomes and create risk models to estimate the probability of poorer outcomes for individual patients using pre-procedural factors.


2020 ◽  
Vol 8 (9) ◽  
pp. 770-779
Author(s):  
Jadry Gruen ◽  
Cesar Caraballo ◽  
P. Elliott Miller ◽  
Megan McCullough ◽  
Catherine Mezzacappa ◽  
...  

Author(s):  
David A. Ramirez ◽  
Mikayle A. Holm ◽  
Andrew Shaffer ◽  
Paul A. Iaizzo

Abstract Implanting Left ventricular assist devices (LVADs) can be life saving therapies that improve life expectancy for the patients that receive it. The target patient population suffer from end-stage heart failure and are therefore susceptible to morbidities arising from a less than ideal surgical implantation. Importantly, the graft that carries the blood from the LVAD pump to the aorta needs to be sized accordingly so as to not cause any compounding complications. The current typical surgical method, is to perform a visual estimation at the time of implantation. This present study proposes a computational tool that utilizes pre-procedural imaging to better calculate the personalized, ideal, LVAD graft length.


Sign in / Sign up

Export Citation Format

Share Document