scholarly journals A Sensitivity-Based Three-Phase Weather-Dependent Power Flow Algorithm for Networks with Local Controllers—Part I: Algorithm Development

Author(s):  
Evangelos Pompodakis ◽  
Arif Ahmed ◽  
Minas Alexiadis

<b>Local voltage controllers (LVCs) are important components of a modern distribution system for regulating the voltage within permissible limits. This manuscript presents a sensitivity-based three-phase weather-dependent power flow algorithm for distribution networks with LVCs. This Part I presents the theoretical development of the proposed algorithm, which has four distinct characteristics: a) it considers the three-phase unbalanced nature of distribution systems, b) the operating state of LVCs is calculated using sensitivity parameters, which accelerates the convergence speed of the algorithm, c) it considers the precise switching sequence of LVCs based on their reaction time delays, and d) the nonlinear influence of weather variations in the power flow is also taken into consideration. Simulations and validation results presented in Part II indicate that the proposed approach outperforms other existing algorithms with respect to the accuracy and speed of convergence, thus making it a promising power flow tool for accurate distribution system analysis. </b><div><b><br></b></div>

2021 ◽  
Author(s):  
Evangelos Pompodakis ◽  
Arif Ahmed ◽  
Minas Alexiadis

<b>Local voltage controllers (LVCs) are important components of a modern distribution system for regulating the voltage within permissible limits. This manuscript presents a sensitivity-based three-phase weather-dependent power flow algorithm for distribution networks with LVCs. This Part I presents the theoretical development of the proposed algorithm, which has four distinct characteristics: a) it considers the three-phase unbalanced nature of distribution systems, b) the operating state of LVCs is calculated using sensitivity parameters, which accelerates the convergence speed of the algorithm, c) it considers the precise switching sequence of LVCs based on their reaction time delays, and d) the nonlinear influence of weather variations in the power flow is also taken into consideration. Simulations and validation results presented in Part II indicate that the proposed approach outperforms other existing algorithms with respect to the accuracy and speed of convergence, thus making it a promising power flow tool for accurate distribution system analysis. </b><div><b><br></b></div>


2021 ◽  
Author(s):  
Evangelos Pompodakis ◽  
Arif Ahmed ◽  
Minas Alexiadis

<b>Local voltage controllers (LVCs) are important components of a modern distribution system for regulating the voltage within permissible limits. This manuscript presents a sensitivity-based three-phase weather-dependent power flow algorithm for distribution networks with LVCs. This Part I presents the theoretical development of the proposed algorithm, which has four distinct characteristics: a) it considers the three-phase unbalanced nature of distribution systems, b) the operating state of LVCs is calculated using sensitivity parameters, which accelerates the convergence speed of the algorithm, c) it considers the precise switching sequence of LVCs based on their reaction time delays, and d) the nonlinear influence of weather variations in the power flow is also taken into consideration. Simulations and validation results presented in Part II indicate that the proposed approach outperforms other existing algorithms with respect to the accuracy and speed of convergence, thus making it a promising power flow tool for accurate distribution system analysis. </b><div><b><br></b></div>


2020 ◽  
Author(s):  
Evangelos Pompodakis ◽  
Arif Ahmed ◽  
Minas Alexiadis

This supplementary document is part of the original 2-Part manuscript titled “A SensitivityBased Three-Phase Weather-Dependent Power Flow Algorithm for Networks with Local Controllers.” This research focuses on proposing a novel sensitivity-based three-phase weather-dependent power flow algorithm for distribution networks with local voltage controllers (LVCs). The proposed algorithm has four distinct characteristics: a) it considers the three-phase unbalanced nature of distribution systems, b) the operating state of LVCs is calculated using sensitivity parameters, which accelerates the convergence speed of the algorithm, c) it considers the precise switching sequence of LVCs based on their reaction time delays, and d) the nonlinear influence of weather variations in the power flow is also taken into consideration. In this supplementary document, the relevant derivations of the sensitivity parameters are presented to complement the original 2-Part manuscript.


2020 ◽  
Author(s):  
Evangelos Pompodakis ◽  
Arif Ahmed ◽  
Minas Alexiadis

This supplementary document is part of the original 2-Part manuscript titled “A SensitivityBased Three-Phase Weather-Dependent Power Flow Algorithm for Networks with Local Controllers.” This research focuses on proposing a novel sensitivity-based three-phase weather-dependent power flow algorithm for distribution networks with local voltage controllers (LVCs). The proposed algorithm has four distinct characteristics: a) it considers the three-phase unbalanced nature of distribution systems, b) the operating state of LVCs is calculated using sensitivity parameters, which accelerates the convergence speed of the algorithm, c) it considers the precise switching sequence of LVCs based on their reaction time delays, and d) the nonlinear influence of weather variations in the power flow is also taken into consideration. In this supplementary document, the relevant derivations of the sensitivity parameters are presented to complement the original 2-Part manuscript.


2020 ◽  
Author(s):  
Evangelos Pompodakis ◽  
Arif Ahmed ◽  
Minas Alexiadis

<p><b>Power flow is an integral part of distribution system planning, monitoring, operation, and analysis. This two-part paper proposes a sensitivity-based three-phase weather-dependent power flow approach for accurately simulating distribution networks with local voltage controllers (LVC). This part II, firstly, presents simulation results of the proposed approach in an 8-Bus and 7-Bus network, which are validated using dynamic simulation. Secondly, simulation results for the IEEE 8500-node network are also presented. An extensive comparison is conducted between the proposed sensitivity-based approach and the other existing power flow approaches with respect to result accuracy and convergence speed. Moreover, the influence of weather and magnetic effects on the power flow results and the LVC states is also investigated. Simulation results confirm that the proposed sensitivity-based approach produces more accurate results than the existing approaches since it considers the actual switching sequence of LVCs as well as the weather and magnetic effects on the network. Moreover, the proposed algorithm exhibits accelerated convergence due to the usage of the sensitivity parameters, which makes it an important tool for distribution system analysis. </b></p>


2021 ◽  
Author(s):  
Evangelos Pompodakis ◽  
Arif Ahmed ◽  
Minas Alexiadis

<p><b>Power flow is an integral part of distribution system planning, monitoring, operation, and analysis. This two-part paper proposes a sensitivity-based three-phase weather-dependent power flow approach for accurately simulating distribution networks with local voltage controllers (LVC). This part II, firstly, presents simulation results of the proposed approach in an 8-Bus and 7-Bus network, which are validated using dynamic simulation. Secondly, simulation results for the IEEE 8500-node network are also presented. An extensive comparison is conducted between the proposed sensitivity-based approach and the other existing power flow approaches with respect to result accuracy and convergence speed. Moreover, the influence of weather and magnetic effects on the power flow results and the LVC states is also investigated. Simulation results confirm that the proposed sensitivity-based approach produces more accurate results than the existing approaches since it considers the actual switching sequence of LVCs as well as the weather and magnetic effects on the network. Moreover, the proposed algorithm exhibits accelerated convergence due to the usage of the sensitivity parameters, which makes it an important tool for distribution system analysis. </b></p>


2020 ◽  
Author(s):  
Evangelos Pompodakis ◽  
Arif Ahmed ◽  
Minas Alexiadis

<p><b>Power flow is an integral part of distribution system planning, monitoring, operation, and analysis. This two-part paper proposes a sensitivity-based three-phase weather-dependent power flow approach for accurately simulating distribution networks with local voltage controllers (LVC). This part II, firstly, presents simulation results of the proposed approach in an 8-Bus and 7-Bus network, which are validated using dynamic simulation. Secondly, simulation results for the IEEE 8500-node network are also presented. An extensive comparison is conducted between the proposed sensitivity-based approach and the other existing power flow approaches with respect to result accuracy and convergence speed. Moreover, the influence of weather and magnetic effects on the power flow results and the LVC states is also investigated. Simulation results confirm that the proposed sensitivity-based approach produces more accurate results than the existing approaches since it considers the actual switching sequence of LVCs as well as the weather and magnetic effects on the network. Moreover, the proposed algorithm exhibits accelerated convergence due to the usage of the sensitivity parameters, which makes it an important tool for distribution system analysis. </b></p>


Author(s):  
Diego Issicaba ◽  
Jorge Coelho

This paper introduces a modified edition of classical Cespedes' load flow method to radial distribution system analysis. In the developed approach, a distribution network is modeled in different complex reference systems and reduced to a set of connected equivalent subnetworks, each without resistance, while graph topology and node voltage solution are preserved. Active power losses are then not dissipated in the modeled subnetworks and active power flows can be obtained as a consequence of radiality. Thus, the proposed method preprocesses a series of variable transformations concomitant to an iterative algorithm using a forward-backward sweep to arrive at the load flow solution. The proposed approach has been tested using literature and actual distribution networks, and efficiency improvements are verified in comparison to Cespedes' load flow method.


Electronics ◽  
2021 ◽  
Vol 10 (21) ◽  
pp. 2663
Author(s):  
Raavi Satish ◽  
Kanchapogu Vaisakh ◽  
Almoataz Y. Abdelaziz ◽  
Adel El-Shahat

Due to the rapid advancement in power electronic devices in recent years, there is a fast growth of non-linear loads in distribution networks (DNs). These non-linear loads can cause harmonic pollution in the networks. The harmonic pollution is low, and the resonance problem is absent in distribution static synchronous compensators (D-STATCOM), which is the not case in traditional compensating devices such as capacitors. The power quality issue can be enhanced in DNs with the interfacing of D-STATCOM devices. A novel three-phase harmonic power flow algorithm (HPFA) for unbalanced radial distribution networks (URDN) with the existence of linear and non-linear loads and the integration of a D-STATCOM device is presented in this paper. The bus number matrix (BNM) and branch number matrix (BRNM) are developed in this paper by exploiting the radial topology in DNs. These matrices make the development of HPFA simple. Without D-STATCOM integration, the accuracy of the fundamental power flow solution and harmonic power flow solution are tested on IEEE−13 bus URDN, and the results are found to be precise with the existing work. Test studies are conducted on the IEEE−13 bus and the IEEE−34 bus URDN with interfacing D-STATCOM devices, and the results show that the fundamental r.m.s voltage profile is improved and the fundamental harmonic power loss and total harmonic distortion (THD) are reduced.


Sign in / Sign up

Export Citation Format

Share Document