scholarly journals Determination of Zn, Cd, Pb and Cu metals in ground water of District Hapur, Uttar Pradesh (India) by anodic stripping voltammetric technique

2014 ◽  
Vol 15 (1&2) ◽  
pp. 195-199
Author(s):  
Udit Mohan ◽  
Randhir Singh ◽  
Prem Singh ◽  
Suhas N. ◽  
Poonam Kashyap Prusty ◽  
...  

In the present communication determination of Zn, Cd, Pb and Cu metals has been carried out from ground water of Hapur District, Uttar Pradesh (India) using differential pulse anodic stripping voltammetry (DPASV) at Hanging Mercury Dropping Electrode (HMDE). Determination of Zn, Cd, Pb and Cu was carried out by using acetate solution as buffer (pH 4.6) with a sweep rate of 0.06 V/sec and pulse amplitude 0.05 V by HMDE by standard addition method. The minimum level of Zn, Cd, Pb and Cu should also be near to zero and the concentration found in the ground water sample of Hapur (India) as analyzed 2.1834, 0.0509, 0.0116 and 0.0331mg/L-1 respectively.

Beverages ◽  
2019 ◽  
Vol 5 (1) ◽  
pp. 6 ◽  
Author(s):  
Juliana Maciel ◽  
Michele Souza ◽  
Lisiane Silva ◽  
Daiane Dias

Metals in wine can originate from natural and anthropogenic sources and their concentrations have significant effects on wine proprieties as well in its conservation. In this work, direct and simultaneous determinations of Zn, Cd, Pb and Cu in wine samples were carried out by differential pulse anodic stripping voltammetry without any steps of previous pretreatment. The samples analyzed presented concentration levels from 4.64 to 69.3 µg L−1 of Zn, from 1.74 to 5.25 µg L−1 of Cd, from 4.57 to 17.9 µg L−1 of Pb and from 1.0 to 10.3 µg L−1 of Cu. Accuracy was evaluated with the standard addition method and recoveries ranged from 82.5 and 130.8% for Zn, from 85.7 to 107.0% for Cd, from 89.7 to 101.0% for Pb and from 81.4 to 105.9% for Cu. With the application of this method, it was possible to quantify the metals in a simple and easy way not requiring sample preparation or other approaches for the destruction of organic substances.


1984 ◽  
Vol 49 (1) ◽  
pp. 45-50 ◽  
Author(s):  
Alireza Aliakbar ◽  
Milan Popl

The use of differential pulse anodic stripping voltammetry in the determination of heavy metals (Cd, Pb, Cu, As) in foodstuffs was studied. Preconcentrating from solutions and dissolution took place on a thin film mercury electrode. A factorial experiment served to determine the effects of variable parameters of the apparatus, a polarographic analyzer: pulse amplitude, pulse period, and potential scan of the working electrode during dissolution. The first two parameters are significant but the scan rate is not. The apparatus parameters were optimized further by the method of response surface fitting near optimum.