Functional Isolation of Single Motor Units of Rat Medial Gastrocnemius Muscle

Author(s):  
Hanna Drzymała-Celichowska ◽  
Jan Celichowski
2007 ◽  
Vol 103 (3) ◽  
pp. 796-802 ◽  
Author(s):  
Lei Cui ◽  
Eric J. Perreault ◽  
Thomas G. Sandercock

Studies on skinned fibers and single motor units have indicated that slow-twitch fibers are stiffer than fast-twitch fibers. This suggests that skeletal muscles with different motor unit compositions may have different short-range stiffness (SRS) properties. Furthermore, the natural recruitment of slow before fast motor units may result in an SRS-force profile that is different from electrical stimulation. However, muscle architecture and the mechanical properties of surrounding tissues also contribute to the net SRS of a muscle, and it remains unclear how these structural features each contribute to the SRS of a muscle. In this study, the SRS-force characteristics of cat medial gastrocnemius muscle were measured during natural activation using the crossed-extension reflex, which activates slow before fast motor units, and during electrical activation, in which all motor units are activated synchronously. Short, rapid, isovelocity stretches were applied using a linear puller to measure SRS across the range of muscle forces. Data were collected from eight animals. Although there was a trend toward greater stiffness during natural activation, this trend was small and not statistically significant across the population of animals tested. A simple model, in which the slow-twitch fibers were assumed to be 30% stiffer than the fast-twitch fibers, was used to simulate the experimental results. Experimental and simulated results show that motor unit composition or firing rate has little effect on the SRS property of the cat MG muscle, suggesting that architectural features may be the primary determinant of SRS.


2014 ◽  
Vol 112 (7) ◽  
pp. 1685-1691 ◽  
Author(s):  
Christopher J. Dakin ◽  
Brian H. Dalton ◽  
Billy L. Luu ◽  
Jean-Sébastien Blouin

Rectification of surface electromyographic (EMG) recordings prior to their correlation with other signals is a widely used form of preprocessing. Recently this practice has come into question, elevating the subject of EMG rectification to a topic of much debate. Proponents for rectifying suggest it accentuates the EMG spike timing information, whereas opponents indicate it is unnecessary and its nonlinear distortion of data is potentially destructive. Here we examine the necessity of rectification on the extraction of muscle responses, but for the first time using a known oscillatory input to the muscle in the form of electrical vestibular stimulation. Participants were exposed to sinusoidal vestibular stimuli while surface and intramuscular EMG were recorded from the left medial gastrocnemius. We compared the unrectified and rectified surface EMG to single motor units to determine which method best identified stimulus-EMG coherence and phase at the single-motor unit level. Surface EMG modulation at the stimulus frequency was obvious in the unrectified surface EMG. However, this modulation was not identified by the fast Fourier transform, and therefore stimulus coherence with the unrectified EMG signal failed to capture this covariance. Both the rectified surface EMG and single motor units displayed significant coherence over the entire stimulus bandwidth (1–20 Hz). Furthermore, the stimulus-phase relationship for the rectified EMG and motor units shared a moderate correlation ( r = 0.56). These data indicate that rectification of surface EMG is a necessary step to extract EMG envelope modulation due to motor unit entrainment to a known stimulus.


1994 ◽  
Vol 76 (6) ◽  
pp. 2663-2671 ◽  
Author(s):  
L. J. Einsiedel ◽  
A. R. Luff

The aim of the study was to determine whether increased motoneuron activity induced by treadmill walking would alter the extent of motoneuron sprouting in the partially denervated rat medial gastrocnemius muscle. An extensive partial denervation was effected by unilateral section of the L5 ventral root, and it is very likely that all units remaining in the medial gastrocnemius were used in treadmill walking. Rats were trained for 1.5 h/day and after 14 days were walking at least 1 km/day. Motor unit characteristics were determined 24 days after the partial denervation and were compared with units from partially denervated control (PDC) animals and with units from normal (control) animals. In PDC rats, force developed by slow, fast fatigue-resistant, and fast intermediate-fatigable motor units increased substantially compared with control animals; that of fast-fatigable units did not increase. In partially denervated exercised animals, force developed by slow and fast-fatigue-resistant units showed no further increase, but fast-intermediate- and fast-fatigable units showed significant increases compared with those in PDC animals. The changes in force were closely paralleled by changes in innervation ratios. We concluded that neuronal activity is an important factor in determining the rate of motoneuron sprouting.


1997 ◽  
Vol 77 (5) ◽  
pp. 2605-2615 ◽  
Author(s):  
John B. Munson ◽  
Robert C. Foehring ◽  
Lorne M. Mendell ◽  
Tessa Gordon

Munson, John B., Robert C. Foehring, Lorne M. Mendell, and Tessa Gordon. Fast-to-slow conversion following chronic low-frequency activation of medial gastrocnemius muscle in cats. II. Motoneuron properties. J. Neurophysiol. 77: 2605–2615, 1997. Chronic stimulation (for 2–3 mo) of the medial gastrocnemius (MG) muscle nerve by indwelling electrodes renders the normally heterogeneous MG muscle mechanically and histochemically slow (type SO). We tested the hypothesis that motoneurons of MG muscle thus made type SO by chronic stimulation would also convert to slow phenotype. Properties of all single muscle units became homogeneously type SO (slowly contracting, nonfatiguing, nonsagging contraction during tetanic activation). Motoneuron electrical properties were also modified in the direction of type S, fatigue-resistant motor units. Two separate populations were identified (on the basis of afterhyperpolarization, rheobase, and input resistance) that likely correspond to motoneurons that had been fast (type F) or type S before stimulation. Type F motoneurons, although modified by chronic stimulation, were not converted to the type S phenotype, despite apparent complete conversion of their muscle units to the slow oxidative type (type SO). Muscle units of the former type F motor units were faster and/or more powerful than those of the former type S motor units, indicating some intrinsic regulation of motor unit properties. Experiments in which chronic stimulation was applied to the MG nerve cross-regenerated into skin yielded changes in motoneuron properties similar to those above, suggesting that muscle was not essential for the effects observed. Modulation of group Ia excitatory postsynaptic potential (EPSP) amplitude during high-frequency trains, which in normal MG motoneurons can be either positive or negative, was negative in 48 of 49 chronically stimulated motoneurons. Negative modulation is characteristic of EPSPs in motoneurons of most fatigue-resistant motor units. The general hypothesis of a periphery-to-motoneuron retrograde mechanism was supported, although the degree of control exerted by the periphery may vary: natural type SO muscle appears especially competent to modify motoneuron properties. We speculate that activity-dependent regulation of the neurotrophin-(NT) 4/5 in muscle plays an important role in controlling muscle and motoneuron properties.


1992 ◽  
Vol 67 (5) ◽  
pp. 1375-1384 ◽  
Author(s):  
A. M. Aniss ◽  
S. C. Gandevia ◽  
D. Burke

1. Reflex responses were elicited in muscles that act at the ankle by electrical stimulation of low-threshold afferents from the foot in human subjects who were reclining supine. During steady voluntary contractions, stimulus trains (5 pulses at 300 Hz) were delivered at two intensities to the sural nerve (1.2-4.0 times sensory threshold) or to the posterior tibial nerve (1.1-3.0 times motor threshold for the intrinsic muscles of the foot). Electromyographic (EMG) recordings were made from tibialis anterior (TA), peroneus longus (PL), soleus (SOL), medial gastrocnemius (MG), and lateral gastrocnemius (LG) muscles by the use of intramuscular wire electrodes. 2. As assessed by averages of rectified EMG, stimulation of the sural or posterior tibial nerves at nonpainful levels evoked a complex oscillation with onset latencies as early as 40 ms and lasting up to 200 ms in each muscle. The most common initial responses in TA were a decrease in EMG activity at an onset latency of 54 ms for sural stimuli, and an increase at an onset latency of 49 ms for posterior tibial stimuli. The response of PL to stimulation of the two nerves began with a strong facilitation of 44 ms (sural) and 49 ms (posterior tibial). With SOL, stimulation of both nerves produced early inhibition beginning at 45 and 50 ms, respectively. With both LG and MG, sural stimuli produced an early facilitation at 52-53 ms. However, posterior tibial stimuli produced different initial responses in these two muscles: facilitation in LG at 50 ms and inhibition in MG at 51 ms. 3. Perstimulus time histograms of the discharge of 61 single motor units revealed generally similar reflex responses as in multiunit EMG. However, different reflex components were not equally apparent in the responses of different single motor units: an individual motor unit could respond slightly differently with a change in stimulus intensity or background contraction level. The multiunit EMG record represents a global average that does not necessarily depict the precise pattern of all motor units contributing to the average. 4. When subjects stood erect without support and with eyes closed, reflex patterns were seen only in active muscles, and the patterns were similar to those in the reclining posture. 5. It is concluded that afferents from mechanoreceptors in the sole of the foot have multisynaptic reflex connections with the motoneuron pools innervating the muscles that act at the ankle. When the muscles are active in standing or walking, cutaneous feedback may play a role in modulating motoneuron output and thereby contribute to stabilization of stance and gait.


1975 ◽  
Vol 38 (5) ◽  
pp. 1217-1231 ◽  
Author(s):  
J. A. Stephens ◽  
R. M. Reinking ◽  
D. G. Stuart

The responses of 13 Golgi tendon organs to graded force development of 29 motor units in medial gastrocnemius of the cat have been studied in five experiments. Of the 13 tendon organs, 11 were responsive to passive stretch within the physiological range of muscle length and 5 were "spontaneously" active at very short lengths where no passive tension could be recorded. The relationship between passive force and the firing rates of the various afferents ranged from a linear one to a power relation (Y = Axb + c) with b, a widely varying exponent. Results support the general conclusion that although many Ib afferents respond to passive force within the physiological range of muscle stretch, this form of stimulus is not a particularly effective one. The statis responses of Golgi tendon organs to active force development produced by single motor units was studied at different muscle lengths. In all cases the apparent sensitivity (change in firing rate per active force developed) decreased as muscle length approached Lo. The static responses of Golgi tendon organs to force developed by single motor units were also studied during fatiguing contractions. The data suggest a sigmoid relationship between force developed at the tendon and the Ib response. The collective response of all 13 tendon organs to active and passive forces at different muscle lengths was also examined. This analysis offered further support for the viewpoint that active motor unit contractions provide themost significant excitatory input to tendon organs and that changes in passive force during muscle stretch have comparatively little effect on the collective tendon organ response. The interaction between active and passive force inputs to the Golgi tendon organs is discussed in relation to the complicated nature of the relationship between forces measured at the tendon and those acting within the receptor capsule. When these complications were taken into account it was possible to explain the differences in responsiveness of a given tendon organ to active contraction of several motor units and to passive force in terms of a single force-firing rate curve for the receptor. It is concluded that changes in the force of contraction of single motor units result in relatively small changes in Ib afferent firing and that during normal muscle contractions, changes in the number of motor units acting on a single receptor must produce far more significant changes in firing rate than changes in the amount of force developed by any single unit. Changes in dynamic Ib sensitivity to single motor unit contractions are also shown to depend on length and in a similar way to the changes in static Ib sensitivity. During fatiguing contractions, a sigmoid relation was found between the dynamic Ib response and the rate of force development by single motor units.


Sign in / Sign up

Export Citation Format

Share Document