scholarly journals Does smoking increase the anesthetic requirement?

2019 ◽  
Vol 49 (5) ◽  
pp. 1271-1276
Author(s):  
Erdoğan ÖZTÜRK ◽  
Mustafa Said AYDOĞAN ◽  
Kazım KARAASLAN ◽  
Zafer DOĞAN ◽  
Ufuk TOPUZ
2020 ◽  
Vol 4 (02) ◽  
pp. 079-085
Author(s):  
Muralidhar Kanchi ◽  
Priya Nair ◽  
Rudresh Manjunath ◽  
Kumar Belani

Abstract Background Perioperative hypothermia is not uncommon in surgical patients due to anesthetic-induced inhibition of thermoregulatory mechanisms and exposure of patients to cold environment in the operating rooms. Core temperature reduction up to 35°C is often seen in off-pump coronary artery bypass graft (OP-CABG) surgery. Anesthetic depth can be monitored by using bispectral (BIS) index. The present study was performed to evaluate the influence of mild hypothermia on the anesthetic depth using BIS monitoring and correlation of BIS with end-tidal anesthetic concentration at varying temperatures during OP-CABG. Materials and Methods In a prospective observational study design in a tertiary care teaching hospital, patients who underwent elective OP-CABG under endotracheal general anesthesia, were included in the study. Standard technique of anesthesia was followed. BIS, nasopharyngeal temperature, and end-tidal anesthetic concentration of inhaled isoflurane was recorded every 10 minutes. The BIS was adjusted to between 45 and 50 during surgery. Results There were 40 patients who underwent OP-CABG during the study period. The mean age was 51.2 ± 8.7 years, mean body mass index 29.8 ± 2.2, and mean left ventricular ejection fraction was 55.4 ± 4.2%. Anesthetic requirement as guided by BIS between 45 and 50 correlated linearly with core body temperature (r = 0.999; p < 0.001). The mean decrease in the body temperature at the end of 300 minutes was 2.2°C with a mean decrease in end-tidal anesthetic concentration of 0.29%. The reduction in end-tidal anesthetic concentration per degree decrease in temperature was 0.13%. None of the patients reported intraoperative recall. Conclusion In this study, BIS monitoring was used to guide the delivery concentration of inhaled anesthetic using a targeted range of 45 to 50. BIS monitoring allowed the appropriate reduction of anesthetic dosing requirements in patients undergoing OP-CABG without risk of awareness. There was a significant reduction in anesthetic requirements associated with reduction of core temperature. The routine use of BIS is recommended in OP-CABG to titrate anesthetic requirement during occurrence of hypothermia and facilitate fast-track anesthesia in this patient population.


1996 ◽  
Vol 84 (4) ◽  
pp. 782-788. ◽  
Author(s):  
Heiko Ropcke ◽  
Helmut Schwilden

Background The volatile anesthetic sparing effect of nitrous oxide in clinical studies is less than might be expected from the additivity of minimum alveolar concentration values. Other studies identify nonadditive interactions between isoflurane and nitrous oxide. The aim of this study was to quantify the interaction of isoflurane and nitrous oxide at a constant median electroencephalographic frequency. Methods Twenty-five patients were studied during laparotomies. Nitrous oxide was randomly administered in concentrations of 0, 20, 40, 60, and 75 vol%, to ten patients for each nitrous oxide concentration. Isoflurane vaporizer settings were chosen so that the median electroencephalographic frequency was held between 2 and 3 Hz. The relationship between nitrous oxide concentrations and required isoflurane concentrations was examined with the method of isoboles. Results Nitrous oxide linearly decreased the isoflurane requirement. Addition of every 10 vol% of nitrous oxide decreases the isoflurane requirement by approximately 0.04 vol%. The total anesthetic requirement of isoflurane and nitrous oxide, expressed in terms of previously reported minimum alveolar concentration values, increased significantly with increasing nitrous oxide concentrations. Conclusions The interaction of isoflurane and nitrous oxide in the dose range 0-75 vol% on median electroencephalographic frequency is compatible with additivity. The potency of nitrous oxide as a substitute for isoflurane is less than on a minimum alveolar concentration basis. Maintaining median electroencephalographic frequency more appropriately reflects the clinical usage of isoflurane and nitrous oxide than does maintaining minimum alveolar concentration.


1997 ◽  
Vol 85 (3) ◽  
pp. 675-680 ◽  
Author(s):  
Baoguo Wang ◽  
Jun Tang ◽  
Paul F. White ◽  
Alan C. Foster ◽  
Heather M. Grettenberger ◽  
...  

2016 ◽  
Vol 34 ◽  
pp. 367-372 ◽  
Author(s):  
Veysel Erden ◽  
Süheyla Abitağaoğlu ◽  
Cihan Güler ◽  
Zuhal Doğan ◽  
Şenay Kırgezen ◽  
...  

1997 ◽  
Vol 86 (2) ◽  
pp. 364-371 ◽  
Author(s):  
Jay W. Johansen ◽  
Ronald Flaishon ◽  
Peter S. Sebel

Background Although beta blockers have been used primarily to decrease unwanted perioperative hemodynamic responses, the sedative properties of these compounds might decrease anesthetic requirements. This study was designed to determine whether esmolol, a short-acting beta 1-receptor antagonist, could reduce the propofol concentration required to prevent movement at skin incision. Methods Sixty consenting patients were premedicated with morphine, and then propofol was delivered by computer-assisted continuous infusion along with 60% nitrous oxide. Patients were randomly divided into three groups, propofol alone, propofol plus low-dose esmolol (bolus of 0.5 mg/kg, then 50 micrograms.kg-1.min-1), and propofol plus high-dose esmolol (bolus of 1 mg/kg, then 250 micrograms.kg-1.min-1). Two venous blood samples were drawn at equilibrium. The serum propofol concentration that prevented movement to incision in 50% of patients (Cp50) was calculated by logistic regression. Results The propofol Cp50 with nitrous oxide was 3.85 micrograms/ ml. High-dose esmolol infusion was associated with a significant reduction in the Cp50 to 2.80 micrograms/ml (P &lt; 0.04). Propofol computer-assisted continuous infusion produced stable serum concentrations with a slight positive blas. Esmolol did not alter the serum propofol concentration. No intergroup differences in heart rate or blood pressure response to intubation or incision were found. Conclusions Esmolol significantly decreased the anesthetic requirement for skin incision. The components and mechanism of this interaction remain unclear. A simple pharmacokinetic interaction between esmolol and propofol does not explain the Cp50 reduction. These results demonstrate an anesthetic-sparing effect of a beta-adrenergic antagonist in humans under clinically relevant conditions.


2005 ◽  
Vol 19 (3) ◽  
pp. 208-212 ◽  
Author(s):  
Miwako Saito ◽  
Toshiyuki Okutomi ◽  
Yuji Kanai ◽  
Junko Mochizuki ◽  
Akihiro Tani ◽  
...  

1970 ◽  
Vol 32 (6) ◽  
pp. 507-514 ◽  
Author(s):  
Edwin S. Munson ◽  
Richard W. Martucci ◽  
Robert EL Smith

Sign in / Sign up

Export Citation Format

Share Document