Low Temperature and Low Phosphorus Electroless Nickel Plating

2011 ◽  
Vol 233-235 ◽  
pp. 302-305 ◽  
Author(s):  
Li Guo Ma ◽  
He Liu ◽  
Ju Jun Li ◽  
Yan Feng He

Direct electroless nickel plating on n-Si(100) wafers in alkaline solutions was performed without any activation procedure in advance. The effect of pH and temperature on the size of deposited metal particles was examined. Moreover, The phosphorus contents of deposits were also analyzed by the energy disperse spectroscopy. The results indicated that the optimal reaction temperature was 60°C and the optimal pH value was 10.0 with a plating rate of about 3.0 µm/hr and the phosphorus content of about 3.6 wt%.

2011 ◽  
Vol 295-297 ◽  
pp. 1522-1525
Author(s):  
Xiao Min Wang ◽  
Jun Duo

Electroless nickel plating on magnesium alloy was studied when NiSO4as the main salt in the solution. The influence of the composition of the solution and process parameters on the coating appearance, the plating rate and bath stability was studied too. As a result, the optimum conditions of electroless nickel are: The main salt and reducing agent molar ratio between 0.3 and 0.45, mixed complexion agents was used, temperature 90°C, pH value 6.5.