Study on Strengthening Glued-Laminated Timber with Aramid Cords and Properties of Composite Materials

2012 ◽  
Vol 583 ◽  
pp. 142-145 ◽  
Author(s):  
Marlena Rajczyk ◽  
Damian Jończyk

This paper presents method of strengthening glued-laminated timber with aramid cords. In order to estimate the increase in load-bearing capacity, numerical analysis was carried out on three beams: unreinforced; reinforced with one layer of aramid cords; and reinforced with two layers of aramid cords. A preliminary numerical analysis showed a reduction of deflections of reinforced beams by about 11 to 14 % and a reduction of 19 to 25 % of normal stress.

Materials ◽  
2021 ◽  
Vol 14 (14) ◽  
pp. 4019
Author(s):  
Klaudia Śliwa-Wieczorek ◽  
Krzysztof Adam Ostrowski ◽  
Justyna Jaskowska-Lemańska ◽  
Anna Karolak

Composite materials are increasingly used to strengthen existing structures or new load-bearing elements, also made of timber. In this paper, the effect of the number of layers of Carbon Fiber Reinforced Polymer (CFRP) on the load-bearing capacity and stiffness of Glued Laminated Timber beams was determined. Experimental research was performed on 32 elements—a series of eight unreinforced beams, and three series of eight reinforced beams: with one, three and five layers of laminate each. The beams with a cross-section of 38 mm × 80 mm and a length of 750 mm were subjected to the four-point bending test according to standard procedure. For each series, destructive force, deflection, mode of failure, and equivalent stiffness were determined. In addition, for the selected samples, X-ray computed tomography was performed before and after their destruction to define the quality of the interface between wood and composite. The results of the conducted tests and analyses showed that there was no clear relationship between the number of reinforcement layers and the load-bearing capacity of the beams and their stiffness. Unreinforced beams failed due to tension, while reinforced CFRP beams failed due to shear. Despite this, a higher energy of failure of composite-reinforced elements was demonstrated in relation to the reference beams.


2020 ◽  
Vol 2 (61) ◽  
pp. 5-11
Author(s):  
S. Shekhorkina ◽  
◽  
К. Shliakhov ◽  
А. Sopilniak ◽  
◽  
...  

With the transition to the design of timber structures in accordance with European standards, problems arise in assessment of the load-bearing capacity of glued timber structures that are caused by insufficient amount of data about the physical, mechanical and deformation properties of glued timber, which is produced in Ukraine. The aim of the work was to determine the load bearing capacity in bending and deflection of a glued timber beam under the action of a concentrated load in the middle of the span. Two glued laminated timber beams were used in the experiment. Both beams were made using lumber from pine wood and a moisture-curing onecomponent polyurethane adhesive Kleiberit PUR 510 FiberBond. The beams have the dimensions of the cross-section: width of 120 mm and height of 180 mm. The length of the beams was 9880 mm. Each beam consisted of 9 layers of 20 mm thick lamellas glued together. Considering the absence of the data on the strength class of the beam material, the theoretical load bearing capacity and deflection were determined according to the characteristics of the GL24h class (minimum strength class), and amounted to 722 kgf and 19.1 cm, respectively. As a result of the tests, the failure load and the deflection of the beams were determined, and the dependences of the deflection on the load were obtained. The actual deflection of the beams determined was 251 mm and 275 mm, which is 1.31 and 1.44 times higher than the predicted deflection. Accordingly, the failure load determined experimentally is 1.96 and 2.03 times higher than the theoretical value. During the tests, the features of the deformation and the nature of the destruction of the beams were investigated. Wherein, the determining factor was the presence of defects in timber and lamellas joints along the length in the most stressed layers. Based on the data obtained, recommendations on manufacturing aimed at the increasing the bending strength of glued laminated timber beams are given. The results obtained will be further used in the development of structural solutions for hybrid timber-concrete floors.


2017 ◽  
Vol 27 (4) ◽  
pp. 143-156 ◽  
Author(s):  
Maciej Szumigała ◽  
Ewa Szumigała ◽  
Łukasz Polus

Abstract This paper presents an analysis of timber-concrete composite beams. Said composite beams consist of rectangular timber beams and concrete slabs poured into the steel sheeting. The concrete slab is connected with the timber beam using special shear connectors. The authors of this article are trying to patent these connectors. The article contains results from a numerical analysis. It is demonstrated that the type of steel sheeting used as a lost formwork has an influence on the load-bearing capacity and stiffness of the timber-concrete composite beams.


2021 ◽  
Vol 1203 (2) ◽  
pp. 022051
Author(s):  
Andrii Mazurak ◽  
Roman Kinasz ◽  
Ivan Kovalyk ◽  
Rostyslav Mazurak ◽  
Vitaliy Kalchenko

Abstract Reinforcement bending reinforced concrete structures by increasing the cross section and assessing the load-bearing capacity of the inclined section such elements is an urgent problem, as not yet accumulated adequate research data on the stress-strain state such structures in the span, which works on shear and shear bending moment and transverse force. Analyzing the development theories calculation reinforced concrete elements inclined to the longitudinal axis, we can identify many areas, the main approach of which was based on the calculation using the bases of material resistance, and the use of empirical dependencies. Theoretical approaches calculation the European construction magazine RILEM TC, SNiP 2.03.01.-84* are considered, DBN B.2.6-98 2009 (Eurocode 2), US ACI 318-19. Experimental studies reinforced concrete elements to determine the load-bearing capacity inclined sections were performed on the basis of 5 samples reinforced concrete beams, 14 reinforced samples of reinforced concrete and shotcrete a total of 19 pieces in four series. Beams were made of concrete in each series fck = 19.08 MPa; fck = 27.74 MPa; fck = 20.48 MPa; fck = 20.48 MPa, respectively, reinforced samples with concrete fck = 17.95 MPa; fck = 19.5 MPa (shotcrete fck = 31.00 MPa); shotcrete fck = 19.9 MPa; fck = 19.9 MPa. Also for the manufacture and reinforcement beams used flat and U-shaped frames with working longitudinal reinforcement Ø22, Ø16, Ø12, Ø10, Ø6 A400C, and transverse reinforcement Ø6 A240C (step 120 mm). Reinforcement inclined sections of the experimental beams was performed on one, two or three sides, depending on the variant of the sample and the type of frame flat or U-shaped. Investigations of beams were performed according to the static scheme - a beam on two supports, span L=2100 mm. Deformations of concrete and reinforcement in the samples when determining the bearing capacity of inclined sections were measured using microindicators of the clock type, strain gauges. According to the results theoretical and experimental studies the bearing capacity inclined sections to the longitudinal axis, we can see a significant reassessment between the theoretical values inclined sections according to the new DBN B.2.6.-98: 2009 (Eurocode 2) over the actual results obtained during testing samples 53-67% for conventional beams, and 27-50% for reinforced beams. The results US regulations ACI 318-19 showed convergence of results in the range of 2-9% for samples without reinforcement and 1-7% for samples with reinforcement, but the values show the excess of experimental data over theoretical, indicating the impossibility of accurately determining the actual final bearing capacity. The results the calculation obtained by the method of SNiP 2.03.01-84*, both unreinforced and reinforced beams has a satisfactory agreement with the experimental values in the range of 6-10%.