scholarly journals Seismic vulnerability assessment to earthquake at urban scale: A case of Mostaganem city in Algeria

2018 ◽  
Vol 10 (1) ◽  
Author(s):  
Belkacem Chaibedra ◽  
Abdelkader Benanane ◽  
Zahra Boutaraa

The focus of this study was the seismic vulnerability assessment of buildings constituting Mostaganem city in Algeria. Situated 320 km to the west of Algiers, Mostaganem city encompasses a valuable cultural and architectural built heritage. The city has suffered several moderate earthquakes in recent years; this has led to extensive structural damage to old structures, especially unreinforced historical buildings. This study was divided into two essential steps, the first step being to establish fragility curves based on a non-linear static pushover analysis for each typology and height of buildings. Twenty-seven pushover analyses were performed by means of SAP2000 software (three analyses for each type of building). The second step was to adopt the US HAZUS software and to modify it to suit the typical setting and parameters of the city of Mostaganem. A seismic vulnerability analysis of Mostaganem city was conducted using HAZUS software after inputting the new parameters of the fragility curves established within the first step. The results indicated that the number of poor-quality buildings expected to be totally destroyed under a 5.5 Mw earthquake scenario could reach more than 28 buildings. Three percent of unreinforced masonry (URM) buildings were completely damaged and 10% were extensively damaged. Of the concrete frame buildings, 6% were extensively damaged and 19% were moderately damaged. According to the built year, 6% of both concrete frame and URM buildings built before 1980 are estimated to be collapsing. Buildings constructed between 1980 and 1999 are more resistant; 8% of those structures were extensively damaged and 18% were moderately damaged. Only 10% of buildings constructed after 1999 were moderately damaged. The results also show that the main hospital of the city, built before 1960, will be extensively damaged during an earthquake of 5.5 Mw. The number of human casualties could reach several hundreds – 10.5% of residents of URM buildings are injured or dead. Compared with the URM buildings, concrete frame buildings have lower casualty rates of 1.5% and 0.5% for those built before and after 1980, respectively. It was concluded that Mostaganem city belongs to seismic vulnerable zones in Algeria; in this regard, an action plan is needed for the rehabilitation of old constructions. In addition, the effectiveness of establishing and introducing new and appropriate fragility curves was demonstrated.

2014 ◽  
Vol 628 ◽  
pp. 49-54 ◽  
Author(s):  
Maurizio Ripepe ◽  
Giorgio Lacanna ◽  
Pauline Deguy ◽  
Mario de Stefano ◽  
Valentina Mariani ◽  
...  

The seismic vulnerability assessment of a building requires a comprehensive knowledge of both building structural features and soils geophysical parameters. To achieve a vulnerability assessment at the urban scale a large amount of data would be necessary, with a consequent involvement of time and economical resources. The aim of this paper is hence to propose a simplified procedure to evaluate the seismic vulnerability of urban centres and possible seismic damage scenarios in order to identify critical areas and/or building typologies to plan future actions of seismic risk mitigation and prevention. The procedure is applied to the outstanding case study of the city of Florence. The research is based on the definition of major building typologies related to construction periods and type of the structural system (masonry or reinforced concrete), the identification of a set of sample buildings, the analysis of the dynamic behaviour and the evaluation of a vulnerability index with an expeditious approach. The obtained results allow to define potential vulnerability and post-event damage scenarios related to the expected levels of peak ground acceleration.


Over the recent years the natural disaster especially due to the earthquake effect on buildings increases which causes loss of life and property in many places all over the world. The latest development leads to finding the direct losses and damage states of the buildings for various intensities of earthquake ground motions. In the present study, seismic vulnerability assessment was done for a medium rise building (G+5). The design peak ground acceleration of 0.16g and 0.36g were considered for the risk assessment. The nonlinear static pushover analysis was done to fine the performance point, spectral acceleration and corresponding spectral acceleration by Equivalent Linearization (EL) method given by Federal Emergency Management Agency (FEMA-440). The four damage states such as slight, moderate, extreme and collapse has been considered as per HAZUS-MR4. The seismic vulnerability in terms of fragility curves was developed to evaluate the damage probabilities based on HAZUS methodology. The discrete and cumulative damage probability was found for all the damage states of the building which shows the building at 0.16g experience slight damage whereas at 0.36g the moderate damage state equally becomes predominant.


Sign in / Sign up

Export Citation Format

Share Document