scholarly journals Benefits and Limitations of Volumetric Modulated Arc Therapy in Treating Bilateral Breast Cancer with Regional Lymph Nodes

2020 ◽  
Vol 09 (04) ◽  
pp. 119-126
Author(s):  
R. P. Srivastava ◽  
K. Vandeputte ◽  
C. De Wagter
2020 ◽  
Vol 61 (5) ◽  
pp. 747-754
Author(s):  
Yoshiko Doi ◽  
Minoru Nakao ◽  
Hideharu Miura ◽  
Shuichi Ozawa ◽  
Masahiro Kenjo ◽  
...  

ABSTRACT To improve the homogeneity and conformity of the irradiation dose for postoperative breast cancer including regional lymph nodes, we planned Hybrid volumetric-modulated arc therapy (VMAT), which combines conventional tangential field mainly for the chest area and VMAT mainly for the supraclavicular area and marginal zone. In this study, we compared the dosimetric impact between traditional 3D conformal radiotherapy (3DCRT) and Hybrid VMAT and observed toxicities following Hybrid VMAT. A total of 70 patients indicated between October 2016 and December 2017 were included. The prescribed dose was 50 Gy/25 fractions. For the dosimetric impact, 3DCRT and Hybrid VMAT plans were compared in each patient with respect to the dosimetric parameters. Toxicities were followed using the Common Terminology Criteria for Adverse Events version 4.0. The median follow-up duration was 319 days. For the dosimetric impact, the homogeneity index (HI) and conformity index (CI) of PTV were significantly improved in the Hybrid VMAT plan compared with that in the 3DCRT plan (HI, 0.15 ± 0.07 in Hybrid VMAT vs 0.41 ± 0.19 in 3DCRT, P < 0.001; CI, 1.61 ± 0.44 in Hybrid VMAT vs 2.10 ± 0.56 in 3DCRT, P < 0.001). The mean irradiated ipsilateral lung dose was not significantly different in both plans (12.0 ± 2.4 Gy in Hybrid VMAT vs 11.8 ± 2.8 Gy in 3DCRT, P < 0.533). Regarding toxicity, there were no patients who developed ≥grade 3 acute toxicity and ≥grade 2 pneumonitis during the follow-up. Hybrid VMAT for postoperative breast cancer including regional lymph nodes was a reasonable technique that improved the homogeneity and conformity of the irradiation dose to the planning target volume while keeping the irradiation dose to organs at risk to a minimum.


2021 ◽  
Author(s):  
Tao Sun ◽  
Xiutong Lin ◽  
Guifang Zhang ◽  
Qingtao Qiu ◽  
Chengqiang Li ◽  
...  

Abstract Background: The Halcyon is a new machine from the Varian company. The purpose of this study was to evaluate the dosimetry of the Halcyon in treatment of bilateral breast cancer with volumetric modulated arc therapy. Methods: On CT images of 10 patients with bilateral breast cancer, four Halcyon plans with different setup fields were generated, and dosimetric comparisons using Bonferroni’s multiple comparisons test were conducted among the four plans. Whole and partial arc plans on the Trilogy and the Halcyon, referred to as T-4arc, T-8arc, H-4arc and H-8arc, were designed. The prescription dose was 50 Gy in 2-Gy fractions. All plans were designed with the Eclipse version 15.5 treatment planning system. The dosimetric differences between whole and partial arc plans in the same accelerator were compared using the Mann-Whitney U test. The better Halcyon plan was selected for the further dosimetric comparison of the plan quality and delivery efficiency between the Trilogy and the Halcyon. Results:Halcyon plans with high‐quality megavoltage cone beam CT setup fields increased the Dmean, D2 and V107 of the planning target volume (PTV) and the V5 and Dmean of the heart, left ventricle (LV) and lungs compared with other Halcyon setup plans. The mean dose and low dose volume of the heart, lungs and liver were significantly decreased in T-8arc plans compared to T-4arc plans. In terms of the V5, V20, V30, V40 and Dmean of the heart, the V20, V30, V40 and Dmean of the LV, the V30, V40, Dmax and Dmean of the left anterior descending artery (LAD), and the V5 and V40 of lungs, H-8arc was significantly higher than H-4arc (p<0.05). Compared with the Trilogy’s plans, the Halcyon’s plans reduced the high-dose volume of the heart and LV but increased the mean dose of the heart. For the dose of the LAD and the V20 and V30 of lungs, there was no significant difference between the two accelerators. Compared with the Trilogy, plans on the Halcyon significantly increased the skin dose but also significantly reduced the delivery time. Conclusion: For the Halcyon, the whole-arc plans have more dosimetric advantages than partial-arc plans in bilateral breast cancer radiotherapy. Although the mean dose of the heart and the skin dose are increased, the doses of the cardiac substructure and other OARs are comparable to the Trilogy, and the delivery time is significantly reduced.


Author(s):  
Reena Phurailatpam ◽  
Tabassum Wadasadawala ◽  
Kamalnayan Chauhan ◽  
Subhajit Panda ◽  
Rajiv Sarin

Abstract Purpose: Dosimetric comparison between volumetric-modulated arc therapy (VMAT) and helical tomotherapy (HT) in the treatment of bilateral breast cancer (BBC). Materials and methods: Ten patients treated on HT were selected retrospectively. Dose prescription was 50 Gy in 25 fractions to breast/chest wall and supraclavicular fossa (SCF) while tumour bed was simultaneously boosted to 61 Gy in 25 fractions. VMAT plans were made with four mono-isocentric partial arcs. The monitoring unit (MU) and treatment time were used to quantify the treatment efficiency. Target volumes were compared for homogeneity index (HI), conformity index (CI) while organs at risk (OARs) were compared for relevant dose volumes and integral doses (IDs). Result: For targets, no significant difference is observed between VMAT and HT in CI but VMAT could give better HI. The mean lung dose, V20 and V5 is 10·6 Gy versus 8·4 Gy (p-value 0·03), 12% versus 11·5% (p-value 0·5) and 78·1% versus 43·4% (p-value 0·005), respectively. The mean heart dose, V30 and V5 is 4·9 Gy versus 4·7 Gy (p-value 0·88), 0·5% versus 1·5% (p-value 0·18) and 26·2% versus 22·8% (p-value 0·4). Integral dose (ID) for the whole body and heart are comparable: 289 Gy kg versus 299 Gy kg (p-value 0·24) and 2·9 Gy kg versus 2·8 Gy kg (p-value 0·80). ID for lungs was significantly higher with VMAT: 7·9 Gy kg versus 6·3 Gy kg (p-value 0·03). There is a 53% reduction in treatment time and 78% in MU with VMAT against HT. Conclusion: VMAT can generate clinically acceptable plans comparable to HT for BBC. HT shows better control over low dose spillage in lungs compared to VMAT thereby increasing ID to lungs. VMAT shows better homogeneity and efficient treatment delivery than HT.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Tao Sun ◽  
Xiutong Lin ◽  
Guifang Zhang ◽  
Qingtao Qiu ◽  
Chengqiang Li ◽  
...  

Abstract Background The Halcyon is a new machine from the Varian company. The purpose of this study was to evaluate the dosimetry of the Halcyon in treatment of bilateral breast cancer with volumetric modulated arc therapy. Methods On CT images of 10 patients with bilateral breast cancer, four Halcyon plans with different setup fields were generated, and dosimetric comparisons using Bonferroni’s multiple comparisons test were conducted among the four plans. Whole and partial arc plans on the Trilogy and the Halcyon, referred to as T-4arc, T-8arc, H-4arc and H-8arc, were designed. The prescription dose was 50 Gy in 2-Gy fractions. All plans were designed with the Eclipse version 15.5 treatment planning system. The dosimetric differences between whole and partial arc plans in the same accelerator were compared using the Mann–Whitney U test. The better Halcyon plan was selected for the further dosimetric comparison of the plan quality and delivery efficiency between the Trilogy and the Halcyon. Results Halcyon plans with high‐quality megavoltage cone beam CT setup fields increased the Dmean, D2 and V107 of the planning target volume (PTV) and the V5 and Dmean of the heart, left ventricle (LV) and lungs compared with other Halcyon setup plans. The mean dose and low dose volume of the heart, lungs and liver were significantly decreased in T-8arc plans compared to T-4arc plans. In terms of the V5, V20, V30, V40 and Dmean of the heart, the V20, V30, V40 and Dmean of the LV, the V30, V40, Dmax and Dmean of the left anterior descending artery (LAD), and the V5 and V40 of lungs, H-8arc was significantly higher than H-4arc (p < 0.05). Compared with the Trilogy’s plans, the Halcyon’s plans reduced the high-dose volume of the heart and LV but increased the mean dose of the heart. For the dose of the LAD and the V20 and V30 of lungs, there was no significant difference between the two accelerators. Compared with the Trilogy, plans on the Halcyon significantly increased the skin dose but also significantly reduced the delivery time. Conclusion For the Halcyon, the whole-arc plans have more dosimetric advantages than partial-arc plans in bilateral breast cancer radiotherapy. Although the mean dose of the heart and the skin dose are increased, the doses of the cardiac substructure and other OARs are comparable to the Trilogy, and the delivery time is significantly reduced.


2020 ◽  
Author(s):  
Tao Sun ◽  
Xiutong Lin ◽  
Guifang Zhang ◽  
Qingtao Qiu ◽  
Chengqiang Li ◽  
...  

Abstract Background: To evaluate the dosimetry of Halcyon in treatment of bilateral breast cancer with volumetric modulated arc therapy. Methods: On CT images of 10 patients with bilateral breast cancer, four Halcyon plans with different setup fields were generated and dosimetric comparisons were conducted among the four plans to select an optimal setup field mode. The four setup-field plans were referred to as CBCT-H, CBCT-L, MV-H, MV-L. Whole and partial arc plans on Trilogy and Halcyon referred to as T-4arc, T-8arc, H-4arc and H-8arc were designed. The dosimetric differences between whole and partial arc plans in the same accelerator were compared to understand the most suitable field setting mode. The better Halcyon plan was selected to the further dosimetric comparison of the plan quality and delivery efficiency between Trilogy and Halcyon. Results: CBCT-H plans increased Dmean, D2 and V107 of planning target volume (PTV) and V5 and Dmean of the heart, left ventricle (LV) and lungs compared to other plans. No significantly dosimetric differences were observed in PTV and organs at risk (OARs) among CBCT-L, MV-H and MV-L. The mean dose and low dose volume of heart, lungs and liver were significantly decreased in T-8arc plans. In terms of V5, V20, V30, V40 and Dmean of the heart, V20, V30, V40 and Dmean of the LV, V30, V40, Dmax and Dmean of the left anterior descending artery (LAD), V5 and V40 of lungs, H-8arc was significantly higher than H-4arc (p<0.05). Compared to Trilogy’s plans, Halcyon’s plans reduced the high-dose volume of the heart and LV, but increased the mean dose of the heart. For the dose of the LAD and the V20, V30 of lungs, there was no statistical difference between the two accelerators. Compared with Trilogy, plans on Halcyon significantly increased the skin dose, but also significantly reduced the delivery time. Conclusion: For Halcyon, the whole-arc plans has more dosimetric advantages in bilateral breast cancer radiotherapy. Although the mean dose of the heart and the skin dose are increased, the dose of the cardiac substructure and other OARs are comparable to the Trilogy, and the delivery time is significantly reduced.


Sign in / Sign up

Export Citation Format

Share Document