scholarly journals Investigating the Fluid Seal of Supraglottic Airway Devices in Humans Using Indicator Dye via the Drainage Tube: A Potential Roadmap for Future Studies

2012 ◽  
Vol 02 (02) ◽  
pp. 18-22 ◽  
Author(s):  
Sebastian G. Russo ◽  
Stephan Cremer ◽  
Ulrike Mühlhäuser ◽  
Christoph Eich ◽  
Michael Quintel ◽  
...  
2020 ◽  
Author(s):  
Jin Hee Ahn ◽  
Jiseon Jeong ◽  
Se Hee Kang ◽  
Ji Eun Yeon ◽  
Eun A Cho ◽  
...  

Abstract Background Supraglottic airway (SGA) devices do not definitively protect the airway from regurgitation of gastric contents. Increased gastric pressure and long operation time are associated with development of complications such as aspiration pneumonia. The aim of this study was to compare intra-gastric pressure between second-generation SGA and endotracheal tube (ETT) devices during long-duration laparoscopic hepatectomy.Methods A total of 66 patients was randomly assigned to two groups; 33 patients each in the ETT and SGA groups. Intra-gastric pressure was continuously measured via a gastric drainage tube with a three-way stopcock connected to the pressure monitoring device. Normal saline was added to the end of the gastric drainage tube at each operation time point.Results Intra-gastric pressure during pneumoperitoneum was no different between the two groups (p = 0.146) or over time (p = 0.094). The mean (SD) pH of the SGA tip measured after operation was 6.7 (0.4), and a pH less than 4 was not observed. Relative risk of postoperative complications was significantly higher in the ETT group relative to the SGA group (sore throat, 5.5; cough,13.0).Conclusions Use of SGA devices does not further increase intra-gastric pressure, even during prolonged upper abdominal laparoscopic surgery. Also, the frequency of postoperative sore throat and cough was significantly lower when the second-generation SGA device was used.Clinical trial registration of Korea (https://cris.nih.go.kr/cris/index.jsp): KCT0003512 Principle investigator: G S K; date of registration February 15, 2019, https://cris.nih.go.kr/cris).


2015 ◽  
Vol 2015 ◽  
pp. 1-6 ◽  
Author(s):  
Sanli Mukadder ◽  
Begec Zekine ◽  
Kayhan Gulay Erdogan ◽  
Ozgul Ulku ◽  
Ucar Muharrem ◽  
...  

We compared proseal, supreme, and i-gel supraglottic airway devices in terms of oropharyngeal leak pressures and airway morbidities in gynecological laparoscopic surgeries. One hundred and five patients undergoing elective surgery were subjected to general anesthesia after which they were randomly distributed into three groups. Although the oropharyngeal leak pressure was lower in the i-gel group initially (mean ± standard deviation; 23.9 ± 2.4, 24.9 ± 2.9, and 20.9 ± 3.5, resp.), it was higher than the proseal group and supreme group at 30 min of surgery after the trendelenburg position (25.0 ± 2.3, 25.0 ± 1.9, and 28.3 ± 2.3, resp.) and at the 60 min of surgery (24.2 ± 2.1, 24.8 ± 2.2, and 29.5 ± 1.1, resp.). The time to apply the supraglottic airway devices was shorter in the i-gel group (12.2 (1.2), 12.9 (1.0), and 6.7 (1.2), resp.,P=0.001). There was no difference between the groups in terms of their fiber optic imaging levels. pH was measured at the anterior and posterior surfaces of the pharyngeal region after the supraglottic airway devices were removed; the lowest pH values were 5 in all groups. We concluded that initial oropharyngeal leak pressures obtained by i-gel were lower than proseal and supreme, but increased oropharyngeal leak pressures over time, ease of placement, and lower airway morbidity are favorable for i-gel.


Sign in / Sign up

Export Citation Format

Share Document