scholarly journals Directional hearing with bilateral bone-conduction hearing aids

2019 ◽  
Vol 62 (4) ◽  
pp. 261-275
Author(s):  
Kimio Shiraishi
2021 ◽  
Vol 70 (2) ◽  
pp. 65-73
Author(s):  
Miroslav Veselý ◽  
Břetislav Gál ◽  
Jiří Hložek ◽  
František Silný ◽  
Jan Hanák

Overview Introduction: Bonebridge is a direct bone conduction hearing implantable system. The aim of the work is to present pilot results of rehabilitation of single sided deafness using this system. Material and methods: Analysis of three patients with single-sideded deafness, who underwent BB implantation in 2018 at the Department of Otorhinolaryngology and Head and Neck Surgery of St. Anna Hospital in Brno. Evaluation parameters: Bern Benefi t in Single-Sided Deafness Questionnaire, experimental examination of directional hearing and hearing in noise test. Results: Questionnaire: Within the visual analog scale in the range of –5 to +5 points, the average rating was + 2.4 points, so listening was rated as easier with Bonebridge than without hearing aids. The ability to locate the sound source was evaluated by 4 and 0–1 points in one and two respondents, respectively. Examination of spatial hearing: without hearing aid, the ability to locate the sound source was signifi cantly impaired in all the examined. With Bonebridge, with a tolerated deviation of 45°, the success rate of sound source localization was 75–100% in the range of 0–360° in the horizontal plane. Hearing in noise test: the greatest improvement in intelligibility (by 30–100%) was achieved with Bonebridge at SNR –5 dB. Conclusion: Bonebridge is not able to restore binaural hearing in patients with single sided deafness, it is a pseudo-binaural correction. Like other implantable bone conduction systems, Bonebridge is benefi tial for patients with single sided deafness in a variety of listening situations. Using experimental audiological tests, the contribution of Bonebridge to understanding sentences in acoustic noise and improving the ability to locate the sound source was found. However, validation of the results would require a larger number of probands. Keywords: single-sided deafness – BAHD – Bonebridge – bone conduction hearing implant – hearing in noise – directional hearing test


1999 ◽  
Vol 24 (3) ◽  
pp. 171-176 ◽  
Author(s):  
C. T. M. Van Der Pouw ◽  
A. F. M. Snik ◽  
C. W. R. J. Cremers

2021 ◽  
Vol 75 (4) ◽  
pp. 1-5
Author(s):  
Joanna Marszał ◽  
Renata Gibasiewicz ◽  
Magdalena Błaszczyk ◽  
Maria Gawlowska ◽  
Wojciech Gawęcki

Introduction: Nowadays, there are many options to treat hearing-impaired patients: tympanoplastic surgery, hearing aids and a wide range of implantable devices. Objective: The aim of this study is to present the mid-term audiological and quality of life benefits after the implantation of the Osia®, a new active piezoelectric bone conduction hearing implant. Material and methods: The state of the tissues in implanted area, as well as audiological and quality of life results were analyzed six, nine and twelve months after implantation in a group of four adult patients with bilateral mixed hearing loss. Results: In all the cases, no postoperative complications were found. One year after surgery the mean audiological gain in FF PTA4 (pure tone average for 0.5, 1, 2, and 4 kHz) was 52.2±3.5 dB in comparison to the unaided situation, the mean speech understanding with Osia® in quiet was 90±8.2% for 50dB SPL, 98.8±2.5% for 65dB SPL and 100±0% for 80dB SPL, and mean speech understanding with Osia® in noise was 37.5%±23.6 for 50dB SPL, 93.8±4.8% for 65dB SPL and 98.8±2.5% for 80dB SPL. There was also an evident improvement in the quality of hearing as well as in the quality of life, measured by the APHAB (Abbreviated Profile of Hearing Aid Benefit) and the SSQ (Speech, Spatial and Qualities of Hearing Scale). Conclusions: The Osia® is an effective treatment option for patients with bilateral mixed hearing loss. The mid-term audiological and quality of life results are excellent, but further observations including bigger groups of patients and a longer follow-up are required.


2020 ◽  
Vol 41 (3) ◽  
pp. 379-385
Author(s):  
Ohad Hilly ◽  
Meirav Sokolov ◽  
Reut Beck Finkel ◽  
Ofir Zavdy ◽  
Rafael Shemesh ◽  
...  

2020 ◽  
Vol 30 (Supplement_2) ◽  
Author(s):  
T Marques ◽  
A Carvalho ◽  
A Miguéis

Abstract Introduction Bone conduction hearing systems can be applied through non-invasive devices, using soft bands that exert pressure on the skin, or they can be surgically implanted (Bone Anchored Hearing Aid - BAHA). However, these bone conduction devices are frequently not well accepted due to the pressure on the head. Therefore, a new non-surgical hearing system was developed not to exert pressure on the skin, the ADHEAR. The bone anchorage in ADHEAR is performed through an adhesive adapter and is indicated for patients with conductive hearing loss and normal inner ear function. Objectives Evaluate the audiological performance with the adhesive bone conduction hearing device (ADHEAR) in a patient with conductive hearing loss. Methodology The study was designed as a prospective single-subject repeated-measure study with the subject serving as his own control. A 29 year old female patient who had a primary surgery due to middle ear cholesteatoma, was adapted with unilateral non-invasive adhesive bone conduction system for the treatment of conductive hearing loss. Air and bone conduction thresholds, word recognition scores (WRS) and speech recognition thresholds (SRT) in quiet and noise were assessed to verify the inclusion criteria of the study. Aided and unaided pure tone audiometry at 0.5, 1, 2 and 4 kHz in free field and speech audiometry in quiet and noise were performed at baseline and after 4 weeks with the ADHEAR. Results The functional gain with the ADHEAR averaged over 0.5, 1, 2, and 4 kHz after 4 weeks of usage of the adhesive hearing system, improved from 55 dB HL to 31dB HL. Speech perception in quiet and noise improved significantly in the aided situation, with SRT in quiet improving from 60 to 35 dB HL, when compared to the unaided condition. Similar results were found in noise. The patient evaluated the ADHEAR system as being useful, and without complaints of skin pressure. There was no adverse skin reaction. Conclusion Hearing performance was significantly better with ADHEAR under all test conditions. Therefore, this transcutaneous hearing system seems to be an excellent alternative for patients who need a hearing solution for conductive hearing loss but for clinical reasons cannot undergo surgery or conventional hearing aids. Furthermore, it preserves skin over the mastoid and reduces the risk of infection. Otherwise it has benefits verified by absence of head pressure and improvement of patient’s quality of life.


2014 ◽  
Vol 15 (sup1) ◽  
pp. S47-S50 ◽  
Author(s):  
Martin Kompis ◽  
Anja Kurz ◽  
Flurin Pfiffner ◽  
Pascal Senn ◽  
Andreas Arnold ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document