scholarly journals Usefulness of Enzyme-linked Immunosorbent Assay Using Recombinant BP180 and BP230 for Serodiagnosis and Monitoring Disease Activity of Bullous Pemphigoid

2012 ◽  
Vol 24 (1) ◽  
pp. 45 ◽  
Author(s):  
Eui Hyung Lee ◽  
Yeon Hee Kim ◽  
Sinyoung Kim ◽  
Song-ee Kim ◽  
Soo-Chan Kim
2011 ◽  
Vol 18 (5) ◽  
pp. 578-586 ◽  
Author(s):  
Woojun Kim ◽  
Ji-Eun Lee ◽  
Xue Feng Li ◽  
Su-Hyun Kim ◽  
Byeong-Gu Han ◽  
...  

Background: Antibodies to aquaporin-4 (AQP4-Ab), known as NMO-IgG, are a sensitive and specific marker for neuromyelitis optica (NMO). Methods: To develop an enzyme-linked immunosorbent assay (ELISA) for AQP4-Ab, we expressed M23 isoform of human AQP4 in a baculovirus system, and used it as an antigen. We measured AQP4-Ab in the sera of 300 individuals: 64 with definite NMO, 31 with high-risk NMO, 105 with multiple sclerosis (MS), 57 with other neurological diseases (ONDs), and 43 healthy controls. We also performed longitudinal measurements of AQP4–Ab in 787 samples collected from 51 patients with definite or high-risk NMO. Results: AQP4-Abs were positive in 72% with definite NMO, 55% with high-risk NMO, and 4% with MS, but none of the OND patients and the healthy individuals. The longitudinal measurement showed AQP4-Ab levels correlating with disease activity. Out of 38 initially seropositive patients, 21 became seronegative under effective immunosuppressive therapy. During most relapses, the serum AQP4-Ab levels were either high or rising compared with the previous value, although rising AQP4-Ab levels did not always lead to acute exacerbation. Two of the 13 initially seronegative patients converted to seropositive following acute exacerbations. Conclusions: We established an AQP4-Ab ELISA, which could be a potential monitoring tool of disease activity.


Diagnostics ◽  
2021 ◽  
Vol 11 (11) ◽  
pp. 1940
Author(s):  
Huang-Chen Chang ◽  
Yen-Ching Wu ◽  
Jun-Peng Chen ◽  
Yi-Da Wu ◽  
Wen-Nan Huang ◽  
...  

This study aimed to compare the test results of anti-double-stranded DNA (anti-dsDNA) antibodies obtained using chemiluminescent immunoassay (CIA) and enzyme-linked immunosorbent assay (ELISA), and investigate predictors of inconsistent results. This retrospective study included 502 patients who underwent CIA and ELISA to determine their anti-dsDNA antibody values within a year. We compared the diagnostic power for SLE, disease activity, and predictive power for lupus nephritis (LN). A multivariate analysis was performed to determine the predictors of inconsistencies. CIA and ELISA were moderately correlated in terms of their consistency (Cronbach’s α = 0.571), and yielded comparably favorable results in terms of SLE diagnostic power and SLE disease activity. However, if the patient had LN, CIA displayed higher predictive power than ELISA (0.620 vs. 0.555, p = 0.026). Compared with the CIA/ELISA double-positive group, the inconsistent group had lower anti-C1q circulating immune complexes (CIC) antibody values (OR: 0.42, 95% CI: 0.18–0.94, p = 0.036), and lower SLEDAI scores (≥4) (OR: 0.33, 95% CI: 0.14–0.79, p = 0.013). Anti-dsDNA antibody detection with CIA exhibited higher predictability for diagnosing LN than did ELISA. In the event of inconsistencies between anti-dsDNA methods, SLE disease activity and CIC test values should be considered simultaneously.


Sign in / Sign up

Export Citation Format

Share Document