scholarly journals Over 5-Year Follow-up of Total Knee Replacement with the Okayama University Type(Mark II).

1991 ◽  
Vol 40 (1) ◽  
pp. 55-58
Author(s):  
Eiji Kawaguchi ◽  
Tetuya Hirano ◽  
Kunihiko Tomoda ◽  
Kenichi Yamashiro ◽  
Kiminori Sakamoto ◽  
...  
The Knee ◽  
2012 ◽  
Vol 19 (4) ◽  
pp. 329-331 ◽  
Author(s):  
David Yeoh ◽  
Nick Nicolaou ◽  
Richard Goddard ◽  
Henry Willmott ◽  
Kim Miles ◽  
...  

2021 ◽  
Vol 108 (Supplement_6) ◽  
Author(s):  
N Baig ◽  
M Ferrari ◽  
A Lukaszewicz

Abstract Background There is a longstanding culture of repeat x-rays after total knee replacement (TKR) as part of follow up, often combined with a clinic review. This is to check that the prosthesis is in a satisfactory position. There are inherently a number of issues with this historic approach including exposure of patients to further radiation who may be asymptomatic, time delays in busy clinics or x-ray departments and costs. Objectives The aim of this audit was to assess whether follow up plain films after TKR are methodically undertaken and of benefit to confirm satisfactory appearance if immediate post -operative x-rays were unremarkable. The findings of a six month follow up x-ray was specifically evaluated. The secondary aim was to establish the timing of further follow up x-rays within the department. Method 200 patients were included within the analysis, they all received a TKR at a major trauma centre, over a one-year period between December 2017 and December 2018. Results It was found that 100% of those patients having a post-operative film had a satisfactory appearance. 78% of patients had at least one further follow op x-ray of which 99.4% were satisfactory. Up to five follow up x-rays were taken with 53.5% of patients having a follow up x-ray at 6 months. Conclusions From the above results there is minimal, if any, evidence within the data set to support routine, additional follow up imaging if initial post-operative films are satisfactory, and the patient is asymptomatic.


1997 ◽  
Vol 79 (4) ◽  
pp. 575-82 ◽  
Author(s):  
DAVID R. DIDUCH ◽  
JOHN N. INSALL ◽  
W. NORMAN SCOTT ◽  
GILES R. SCUDERI ◽  
DAVID FONT-RODRIGUEZ

2010 ◽  
Vol 30 (S 01) ◽  
pp. S104-S106
Author(s):  
W. Miesbach ◽  
L. M. Sahner ◽  
A. Kurth ◽  
B. Habermann

Summary Purpose Purpose of this retrospective study was to evaluate our own results after total knee replacement in patients with haemophilia. Patients, material, method: 30 patients with haemophilia who underwent total knee replacement between 1987 and 2005 were included. We used the clinical and radiological Knee Society Score. Furthermore, the Petterson and the Arnold and Hilgartner score were applied. Results: The mean age at the time of surgery was 43.2 (27–66). At the time of follow- up examination the mean age was 51.6 (30–82) years. The mean follow-up was 7.1 (2–20) years. Preoperative, he mean Arnold and Hilgartner score was 4.17 (± 0.59) and the mean Petterson-Score was 9 ± 2.29. Compared to the preoperative deficiency in knee function (KSS-Score 88.17 ± 33.58) an improvement with 166.67 (± 22.73) points was seen. 1 patient showed an aseptic loosening after 11 years. Discussion: Total knee replacement in patients with haemophilia improves knee function and quality of life. The results of our study represent results in earlier published studies. Compared to a non-haemo-philic normal population the rate of perioper-ative complications was not increased.


Sign in / Sign up

Export Citation Format

Share Document