knee replacement arthroplasty
Recently Published Documents


TOTAL DOCUMENTS

83
(FIVE YEARS 6)

H-INDEX

12
(FIVE YEARS 0)

2021 ◽  
pp. 701-711
Author(s):  
Charalambos Panayiotou Charalambous


2021 ◽  
pp. 713-723
Author(s):  
Charalambos Panayiotou Charalambous


Medicina ◽  
2021 ◽  
Vol 57 (6) ◽  
pp. 589
Author(s):  
Chang-Hyung Lee ◽  
In-Hye Kim

Background and Objectives: Early intensive exercise after total knee replacement arthroplasty (TKRA) has become increasingly popular due to its ability to enhance knee physical function and reduce pain. When implemented exclusively, aquatic exercise (AE) appears to be more advantageous than land exercise (LE), particularly in the early phase after TKRA. Our study aimed to compare the clinical efficacy of AE and LE with respect to their effects on pain and physical function after TKRA. Materials and Methods: Between February 2008 and January 2020, 100 female patients who underwent TKRA were enrolled in this retrospective study. We measured the range of motion (ROM) of the knee, the isokinetic strength of the knee joint (function), and pain both initially and one month after TKRA. Two weeks after TKRA, the participants were enrolled in either the AE or the LE program for a total of two weeks. Two 30 min sessions of intensive ROM and knee strengthening exercises and balance training were provided to the AE and LE groups for 10 days. The home exercise group (HE) only received information on ROM and strengthening exercises. There were 33, 21, and 46 patients allocated to the AE, LE, and HE groups, respectively. Results: The ROM of the side on which surgery was performed improved significantly in all groups, as did the pain scores. In the AE group, the knee flexor strength showed a tendency toward improvement. Contrastingly, there was no significant improvement in the knee extensor strength in the AE group. Conclusions: Overall, the AE and LE groups showed superior outcomes compared with HE. In addition, the AE group demonstrated some improvement in knee muscle strength even with a short hospital stay. Further study with long-term follow-up should be performed to better define the outcomes.



2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Yong-Beom Kim ◽  
Hyung-Suk Choi ◽  
Hyung-Ki Cho ◽  
Gi-Won Seo

Abstract Background Total knee replacement arthroplasty (TKA) is frequently performed in South Korea. Simple swelling-associated blistering around the periphery of the operative wound is a well-known adverse effect. However, in rare cases, the blisters are bullous pemphigoid (BP). Case presentation A 75-year-old male presented with knee pain that had not improved despite 5 years of medication. We performed TKA of the left knee, placing a Stryker posteriorly stabilized prosthesis. Three days later, blisters developed near the buttocks and thighs and, on day 10 after surgery, around the operative site. A skin biopsy revealed BP. Commencing on day 14 after surgery, prednisolone 10 mg was administered twice daily. The symptoms improved by 3 weeks after surgery and were healed at 4 months. After 1 year, we performed TKA of the right knee. On day 2 after surgery, as formerly, blisters developed on the buttocks and an immediate biopsy revealed BP. Commencing on day 3 after surgery, prednisolone 10 mg was administered twice daily. On day 10 after surgery, the blisters on the buttocks had improved and no blisters were observed at the surgical site. All symptoms had resolved by 2.5 months after surgery. Conclusions After TKA surgery, generalized BP may develop, diagnosed via skin biopsy. A quick diagnosis is important because early treatment can prevent symptom progression and shorten treatment.





10.29007/65qr ◽  
2020 ◽  
Author(s):  
Kamal Deep ◽  
Frederic Picard

The accuracy of implantation using computer navigation and robotic total knee replacement (TKR) has been proven. Time taken during surgery has been a factor for surgeons for not using the technology. Aim of this study was to analyse time taken in different steps and identify which part needs improvement. Robotic time was compared to computer navigation. Methods: 15TKR were performed with MAKO robot. Software for the ligament balancing was used. All had CT scan preoperatively. Time of different surgical steps was recorded. Time for computer navigation was recorded too. After joint exposure, trackers and verification pins for tibia and femur were inserted. Femoral registration matching started at 10.8 minutes (SD3.3 Range7-20). It took 3.2 minutes to match femoral anatomy to CT scan. Tibial registration done at 14.1minutes (SD3 Range10- 23). Once matching was accepted to required accuracy, tibial cut was made at 22.2 minutes (SD4.4 Range 15-30). Next the soft tissues were assessed with tensioner. It took 6.3 minutes (SD 5.6). Final femoral preparation done at 35.7 minutes (SD 5.6 Range25-45). Trial performed at 52 minutes (SD7.3 Range42-63). Implants were cemented at 63.4 minutes (SD8 Range50-72). Wound closed at 77.6 minutes (SD9.5 Range65-97). The computer navigated TKR surgery took 70 minutes on an average. Compared to navigation, robotic technique took approximately 7 minutes longer, not significantly different. This could be due to learning curve of the surgical and theatre team. Improvement is required in different steps. The familiarity of staff will increase the efficiency. Registration matching took 11.4 minutes. Femoral preparation took 17 minutes. These steps could be streamlined.



Author(s):  
Sang Oon Baek ◽  
Jeonghwan Shin ◽  
Jong Keun Song ◽  
Jun Yong Lee

Total knee replacement arthroplasty is a common procedure and postoperative wound complications are sometimes inevitable. Although invasive reconstructive surgery may be an option for nonhealed wounds, such procedures can limit early rehabilitation, adversely affecting the range of joint motion. Patients can achieve a wider range of motion if they undergo early rehabilitation with a conservative approach. From 2015 to 2017, 5 patients with comorbidities who underwent total knee replacement arthroplasty were referred to the reconstructive surgery department for nonhealed open wounds. Depending on their comorbidities and conditions, the patients underwent negative-pressure wound therapy based on multimodal conservative treatment. During the treatment, the patients continued rehabilitation. In the 5 patients, the mean duration of complete wound healing was 65.2 days (range = 57-81), during which all open wounds were well healed. For final wound closure, the patients underwent skin grafting, dermatotraction, or collagen dressing. Four patients achieved ranges of joint motion over 100 degrees after treatment. We believe that early coverage is important for open wounds. For complicated open wounds after total knee replacement arthroplasty in patients with comorbidities, less invasive multimodal treatment along with early rehabilitation may be more effective to achieve adequate final range of joint motion.



2020 ◽  
Vol 15 (2) ◽  
pp. 209-216
Author(s):  
Gunn Hee Kim ◽  
Joon Woo Lee ◽  
Go Eun Kim ◽  
Seong Su Lee ◽  
Shill Lee Son ◽  
...  

Background: The analgesic effect of perineural opioid in clinical practice are still controversial. This randomized controlled trial compared analgesic effect of ropivacaine with fentanyl or ropivacaine alone for continuous femoral nerve block following unilateral total knee arthroplasty. Methods: Fourty patients of ASA PS Ⅰ or Ⅱ receiving total knee arthroplasty with spinal anesthesia were enlisted and randomly allocated into two groups. Group R; bolus injection of 0.375% ropivacaine, 30 ml and an infusion of 0.2% ropivacaine at 8 ml/h (n = 20). Group RF; 0.375% ropivacaine, 29 ml added with 50 μg of fentanyl as a bolus and an infusion of 0.2% ropivacaine mixed with 1 μg/ml of fentanyl at 8 ml/h (n = 20). Local anesthetic infusion via a femoral nerve catheter was started at the end of operation and continued for 48 h. Intravenous patient-controlled analgesia with hydromorphone (0.15 mg/ml, 0-1-10) were used for adjuvant analgesics. Position of catheter tip and contrast distribution, visual analog scale of pain, hydromorphone consumption, side effects were recorded for 48 h after operation. Patient satisfaction for the pain control received were noted. Results: The pain visual analogue scale, incidences of side effects and satisfaction were not different between the two groups (P > 0.05), but the hydromorphone usage at 48 h after operation were lower in the Group RF than in the Group R (P = 0.047). Conclusions: The analgesic effect of ropivacaine with fentanyl for continuous femoral nerve block after knee replacement arthroplasty was not superior to that of the ropivacaine alone.



Sign in / Sign up

Export Citation Format

Share Document