scholarly journals Dosimetric characterization of a new two-dimensional diode detector array used for stereotactic radiosurgery quality assurance

2021 ◽  
Vol 19 (2) ◽  
pp. 281-289
Author(s):  
K. Yasui ◽  
Y. Saito ◽  
S. Ogawa ◽  
N. Hayashi ◽  
◽  
...  
2016 ◽  
Vol 43 (6Part22) ◽  
pp. 3596-3596
Author(s):  
M Muthukumaran ◽  
D Manigandan ◽  
V Murali ◽  
S Vikraman ◽  
S Chitra ◽  
...  

2014 ◽  
Vol 41 (5) ◽  
pp. 051704 ◽  
Author(s):  
Miljenko Markovic ◽  
Sotirios Stathakis ◽  
Panayiotis Mavroidis ◽  
Ines-Ana Jurkovic ◽  
Nikos Papanikolaou

2019 ◽  
Vol 64 (10) ◽  
pp. 105009 ◽  
Author(s):  
D N Makris ◽  
E P Pappas ◽  
E Zoros ◽  
N Papanikolaou ◽  
D L Saenz ◽  
...  

2013 ◽  
Vol 40 (6Part15) ◽  
pp. 278-278
Author(s):  
M Markovic ◽  
S Stathakis ◽  
C Ha ◽  
B Poppe ◽  
A Gutierrez ◽  
...  

Author(s):  
Dražan Jaroš ◽  
Goran Kolarević ◽  
Aleksandar Kostovski ◽  
Milovan Savanović ◽  
Dejan Ćazić ◽  
...  

Introduction: Gated tangential field-in-field (FIF) technique is used to lower the dose to organs at risk for breast cancer radiotherapy (RT). In this study, the authors investigated the accuracy of the delivered treatment plan with and without gating using a two-dimensional detector array for patient-specific verification purposes.Methods: In this study, a 6MV beams were used for the merged FIF RT (forward Intensity Modulated Radiation Therapy). The respiration signals for gated FIF delivery were obtained from the one-dimensional moving phantom using the real-time position management (RPM) system (Varian Medical Systems, Palo Alto, CA). RPM system used for four-dimensional computed tomography scanner light-speed, GE is based on an infrared camera to detect motion of external 6-point marker. The beams were delivered using a Clinac iX (Varian Medical Systems, Palo Alto, CA) with the multileaf collimator Millennium 120. The MapCheck2 (SunNuclear, Florida) was used for the evaluation of treatment plans. MapCheck2 was validated through a comparison with measurements from a farmer-type ion chamber. Gated beams were delivered using a maximum dose rate with varying duty cycles and analyzed the MapCheck2 data to evaluate treatment plan delivery accuracy.Results: Results of the gamma passing rate for relative and absolute dose differences for all ungated and gated beams were between 95.1% and 100%.Conclusion: Gated FIF technique can deliver an accurate dose to a detector during gated breast cancer RT. There is no significance between gated and ungated patient-specific quality assurance (PSQA); one can use ungated PSQA for verification of treatment plan delivery


Sign in / Sign up

Export Citation Format

Share Document