The use of propofol as an induction agent for halothane and isoflurane anesthesia in dogs

1998 ◽  
Vol 34 (1) ◽  
pp. 84-91 ◽  
Author(s):  
A Bufalari ◽  
SM Miller ◽  
C Giannoni ◽  
CE Short

Cardiovascular, pulmonary, and quantitative electroencephalographic parameters were assessed in 12 anesthetized dogs to determine the compatibility of the injectable anesthetic propofol with halothane and isoflurane. No cases of apnea were observed during induction of anesthesia. An adequate level of anesthesia was established in each protocol as judged by both the lack of response to mechanical noxious stimuli (i.e., tail clamping) and evidence of reduction in total amplitude of brain wave activity. The initial propofol-mediated decrease in arterial blood pressure continued during either halothane (52.4%) or isoflurane (38%) anesthesia without a simultaneous increase in heart rate. The results of this study suggest that propofol, in combination with inhalant agents, can be used effectively and safely for canine anesthesia in veterinary practice.

2020 ◽  
Vol 48 ◽  
Author(s):  
Bárbara Silva Correia ◽  
Eduardo Raposo Monteiro ◽  
João Victor Barbieri Ferronatto ◽  
Luciana Branquinho Queiroga ◽  
José Ricardo Herrera Becerra

Background: Arterial blood pressure is one of the most commonly variables monitored during anesthetic procedures in veterinary patients. The most reliable method for measuring arterial blood pressure in dogs and cats is the direct (invasive) method. However, the oscillometric method is less complex and more practical for clinical routine in small animals. Nevertheless, oscillometric monitors present great variability in accuracy. The present study aimed to determine the accuracy of the Delta Life DL 1000 oscillometric monitor for measurement of systolic, mean and diastolic blood pressures (SAP, MAP and DAP, respectively) in anesthetized dogs of different weight ranges.Materials, Methods & Results: This study was approved by the Institutional Ethics Committee of Animal Use. Fifteen female dogs of different breeds, weighing 11.6 ± 10.0 kg and with a mean age of 48 ± 51 months were used. All animals were scheduled for elective surgery under general anesthesia in the Institution Veterinary Hospital. Dogs were anesthetized with morphine, propofol and isoflurane and had one 20 or 22 gauge catheter introduced into the dorsal pedal artery for continuous, invasive monitoring of SAP, MAP and DAP. A blood pressure cuff was positioned over the middle third of the radius and connected to Delta Life DL 1000 monitor. Oscillometric readings of SAP, MAP and DAP were registered every 5 minutes, and invasive values were simultaneously recorded. Values obtained with both methods were compared (invasive versus oscillometric) by use of the Bland Altman method to determine the bias, standard deviation of bias and 95% limits of agreement. The percentages of errors between the methods within 10 mmHg and within 20 mmHg were calculated. The results obtained were compared with the criteria from the American College of Veterinary Internal Medicine (ACVIM) for validation of indirect methods of arterial blood pressure measurement. Data were stratified into two groups according to the weight: < 10 kg (Group 1; n = 9); and ≥ 10 kg (Group 2; n = 6). In Group 1, 119 paired measurements were obtained, four of which classified as hypotension (SAP < 90 mmHg), 98 as normotension (SAP from 90 to 140mmHg) and 17 as hypertension (SAP > 140 mmHg). Bias (± SD) values in Group 1 were as follows: SAP, 5.2 ± 18.1 mmHg; MAP, -3.4 ± 17.2 mmHg; and DAP, 12.0 ± 17.5 mmHg. The percentages of errors within 10 mmHg were 40.3% for SAP; 45.4% for MAP and 28.6% for DAP. The percentages of errors within 20 mmHg were 72.3% for SAP, 84.0% for MAP and 68.1% for DAP. In Group 2, 66 paired measurements were obtained, nine of which classified as hypotension, 56 as normotension and one as hypertension. Bias (± SD) in Group 2 were as follows: SAP, 13.6 ± 14.3 mmHg; MAP, -1.1 ± 13.5 mmHg; and DAP, 8.2 ± 16.0 mmHg. The percentages of errors within 10 mmHg were 33.3% for SAP, 77.3% for MAP and 33.3% for DAP. The percentages of errors within 20 mmHg were 65.1% for SAP, 92.4% for MAP and 83.4% for DAP.Discussion: Based on the results of this study and reference criteria from the ACVIM, the Delta Life DL 1000 monitor had a poor accuracy for SAP, MAP and DAP and did not meet the criteria from the ACVIM in anesthetized dogs under 10 kg. Measurements of MAP in dogs ≥ 10 kg met the ACVIM criteria, but measurements of SAP and DAP did not. Based on the findings in this study, the DL 1000 oscillometric monitor is not recommended for blood pressure measurement in anesthetized dogs < 10 kg. In dogs ≥ 10 kg, measurements of MAP yielded acceptable values, but SAP and DAP measurements did not.


1965 ◽  
Vol 209 (2) ◽  
pp. 397-403 ◽  
Author(s):  
Hermes A. Kontos ◽  
H. Page Mauck ◽  
David W. Richardson ◽  
John L. Patterson

The possibility that mechanisms secondary to the increased ventilation may contribute significantly to the circulatory responses to systemic hypoxia was explored in anesthetized dogs. In 14 spontaneously breathing dogs systemic hypoxia induced by breathing 7.5% oxygen in nitrogen increased cardiac output, heart rate, mean arterial blood pressure, and femoral arterial flow, and decreased systemic and hindlimb vascular resistances. In 14 dogs whose ventilation was kept constant by means of a respirator pump and intravenous decamethonium, systemic hypoxia did not change cardiac output, femoral arterial flow, or limb vascular resistance; it significantly decreased heart rate and significantly increased systemic vascular resistance. In seven spontaneously breathing dogs arterial blood pCO2 was maintained at the resting level during systemic hypoxia. The increase in heart rate was significantly less pronounced but the other circulatory findings were not different from those found during hypocapnic hypoxia. Thus, mechanisms secondary to increased ventilation contribute significantly to the circulatory responses to systemic hypoxia. Hypocapnia accounts partly for the increased heart rate, but not for the other circulatory responses.


1957 ◽  
Vol 189 (3) ◽  
pp. 576-579 ◽  
Author(s):  
E. Allbaugh Farrand ◽  
R. Larsen ◽  
Steven M. Horvath

The changes in splanchnic blood flow and related metabolic functions which occurred as the result of the infusion of 0.1 µg/kg/min. of l-epinephrine and l-norepinephrine for 10 minutes were measured in anesthetized dogs. l-Epinephrine elicited a marked increase in estimated splanchnic blood flow and no change in mean arterial pressure. While a significantly increased mean arterial blood pressure was observed following the administration of l-norepinephrine, no change in estimated splanchnic blood flow occurred. Arterial oxygen content was increased significantly with both drugs. Utilization of oxygen by the splanchnic bed was not changed during the infusion of either drug but was increased during the postepinephrine infusion period.


1990 ◽  
Vol 259 (4) ◽  
pp. F645-F652 ◽  
Author(s):  
S. Y. Chou ◽  
A. Dahhan ◽  
J. G. Porush

The renal actions of endothelin were examined by infusing it intrarenally in anesthetized dogs at 4 ng.min-1.kg-1 without affecting arterial blood pressure or cardiac output. Endothelin infusion caused a transient and significant increase in renal blood flow (RBF) by 13 +/- 2%, followed by large decreases in RBF and glomerular filtration rate (GFR; by 26 +/- 2 and 23 +/- 7%, respectively) but did not alter urine flow rate or absolute sodium excretion. After endothelin infusion, renal venous and arterial plasma 6-ketoprostaglandin F1 alpha increased from 250 +/- 58 and 117 +/- 31 to 1,044 +/- 249 and 617 +/- 211 pg/ml, respectively, and its renal output increased from 339 +/- 99 to 963 +/- 202 pg.min-1.g-1 (P less than 0.01 for all). The renal prostacyclin synthesis was augmented by endothelin without stimulating the renal renin release or norepinephrine output. Inhibition of prostaglandin synthesis with indomethacin partially prevented the early renal vasodilation induced by endothelin, which then caused a more pronounced decline in RBF and GFR (by 65 +/- 7 and 54 +/- 8%, respectively). With suppression of prostacyclin synthesis, inhibition of renin release by endothelin was observed. Thus the vasoconstrictive effects of endothelin on renal hemodynamics are significantly modified by its ability to enhance production of vasodilators, including prostacyclin.


1962 ◽  
Vol 17 (1) ◽  
pp. 83-86 ◽  
Author(s):  
James F. Nickel ◽  
John A. Gagnon ◽  
Leonard Levine

Eight anesthetized dogs, given Clostridium perfringens type A toxic filtrate into the hind-limb muscles, showed severe spreading edema, hemoconcentration, marked reduction in para-aminohippurate (PAH) and creatinine clearances, and a rise in the renal vascular resistance. In the first 4 hr sodium excretion fell sharply, and mean arterial blood pressure, slightly. In eight similar dogs venous-occlusive pneumatic tourniquets were applied high on both hind limbs for 90 min. Edema was localized and minimal. Hematocrit was unchanged. PAH and creatinine clearances were extremely low in the second 30-min period of the occlusion but had risen somewhat in the last 30-min period. Sodium excretion was greatly reduced. Arterial pressure and vascular resistance rose very significantly. Upon removal of the tourniquets, PAH and creatinine clearances, blood pressure, and renal vascular resistance returned toward normal. Sodium excretion continued to fall. In many respects the renal changes resulting from two different forms of peripheral trauma are similar. Submitted on August 14, 1959


2020 ◽  
Vol 81 (8) ◽  
pp. 635-641
Author(s):  
Zoë R. Jacobs-Fohrman ◽  
Tamsin S. Barnes ◽  
Margaret M. McEwen ◽  
Wendy A. Goodwin

Sign in / Sign up

Export Citation Format

Share Document