Valvular Regurgitation And Rhythm Have Not An Impact On Mitral Valve Area: An Echocardiographic Study

10.5580/2c04 ◽  
2012 ◽  
Vol 10 (2) ◽  
2013 ◽  
Vol 61 (10) ◽  
pp. E883
Author(s):  
Jun Tanaka ◽  
Takashi Matsumoto ◽  
Wen Loong Yeow ◽  
Kenji Harada ◽  
Javier Berdejo ◽  
...  

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Yahya Dadjo ◽  
Maryam Moshkani Farahani ◽  
Reza Nowshad ◽  
Mohsen Sadeghi Ghahrodi ◽  
Alireza Moaref ◽  
...  

Abstract Background Rheumatic heart disease (RHD) is still a concerning issue in developing countries. Among delayed RHD presentations, rheumatic mitral valve stenosis (MS) remains a prevalent finding. Percutaneous transvenous mitral commissurotomy (PTMC) is the intervention of choice for severe mitral stenosis (MS). We aimed to assess the mid-term outcome of PTMC in patients with immediate success. Methods In this retrospective cohort study, out of 220 patients who had undergone successful PTMC between 2006 and 2018, the clinical course of 186 patients could be successfully followed. Cardiac-related death, undergoing a second PTMC or mitral valve replacement (MVR) were considered adverse cardiac events for the purpose of this study. In order to find significant factors related to adverse cardiac outcomes, peri-procedural data for the studied patients were collected.The patients were also contacted to find out their current clinical status and whether they had continued secondary antibiotic prophylaxis regimen or not. Those who had not suffered from the adverse cardiac events were additionally asked to undergo echocardiographic imaging, in order to assess the prevalence of mitral valve restenosis, defined as mitral valve area (MVA) < 1.5 cm2 and loss of ≥ 50% of initial area gain. Results During the mean follow-up time of 5.69 ± 3.24 years, 31 patients (16.6% of patients) had suffered from adverse cardiac events. Atrial fibrillation rhythm (p = 0.003, HR = 3.659), Wilkins echocardiographic score > 8 (p = 0.028, HR = 2.320) and higher pre-procedural systolic pulmonary arterial pressure (p = 0.021, HR = 1.031) were three independent predictors of adverse events and immediate post-PTMC mitral valve area (IMVA) ≥ 2 cm2 (p < 0.001, HR = 0.06) was the significant predictor of event-free outcome. Additionally, follow-up echocardiographic imaging detected mitral restenosis in 44 patients (23.6% of all patients). The only statistically significant protective factor against restenosis was again IMVA ≥ 2 cm2 (p = 0.001, OR = 0.240). Conclusion The mid-term results of PTMC are multifactorial and may be influenced by heterogeneous peri-procedural determinants. IMVA had a great impact on the long-term success of this procedure. Continuing secondary antibiotic prophylaxis was not a protective factor against adverse cardiac events in this study. (clinicaltrial.gov registration: NCT04112108).


2021 ◽  
pp. 021849232110304
Author(s):  
Mehrnoush Toufan ◽  
Zahra Jabbary ◽  
Naser Khezerlou aghdam

Background To quantify valvular morphological assessment, some two-dimensional (2D) and three-dimensional (3D) scoring systems have been developed to target the patients for balloon mitral valvuloplasty; however, each scoring system has some potential limitations. To achieve the best scoring system with the most features and the least restrictions, it is necessary to check the degree of overlap of these systems. Also the factors related to the accuracy of these systems should be studied. We aimed to determine the correlation between the 2D Wilkins and real-time transesophageal three-dimensional (RT3D-TEE) scoring systems. Methods This cross-sectional study was performed on 156 patients with moderate to severe mitral stenosis who were candidates for percutaneous balloon valvuloplasty. To morphologic assessment of mitral valve, patients were examined by 2D-transthoracic echocardiography and RT3D-TEE techniques on the same day. Results A strong association was found between total Wilkins and total RT3D-TEE scores (r = 0.809, p < 0.001). The mean mitral valve area assessed by the 2D and 3D was 1.07 ± 0.25 and 1.03 ± 0.26, respectively, indicating a mean difference of 0.037 cm2 (p = 0.001). We found a strong correlation between the values of mitral valve area assessed by 2D and 3D techniques (r = 0.846, p < 0.001). Conclusion There is a high correlation between the two scoring systems in terms of evaluating dominant morphological features. Partially, mitral valve area overestimation in the 2D-transthoracic echocardiography and its inability to assess commissural involvement as well as its dependence on patient age were exceptions in this study.


1994 ◽  
Vol 127 (5) ◽  
pp. 1348-1353 ◽  
Author(s):  
Marcus F Stoddard ◽  
Charles R Prince ◽  
Nasar M Ammash ◽  
John L Goad

1995 ◽  
Vol 3 (2) ◽  
pp. 75-77 ◽  
Author(s):  
Gutti Ramasubrahmanyam ◽  
Dronamraju Dilip ◽  
Pirovam Venkat Ramnarayan ◽  
Raju Subramaniam Iyer ◽  
Kothapalle Venugopal Naidu

A 22-year-old female with mirror image dextrocardia and rheumatic valvular mitral stenosis underwent closed mitral valvotomy using a Tubb's dilator with good results. Despite abnormal position of situs, the surgical approach was simple through right anterolateral thoracotomy, and the operator's hands were mirror image to that of levocardia valvotomy in certain steps. Preoperative mitral valve area was 0.8 cm2, and peak and mean diastolic gradients were 21 and 15 mmHg respectively. Postoperatively, valve area improved to 2.16 cm2, and peak and mean diastolic gradients were 8 and 3.1 mmHg, respectively.


2017 ◽  
Vol 33 (12) ◽  
pp. 1701-1707 ◽  
Author(s):  
Kwan Leung Chan ◽  
Shin-Yee Chen ◽  
Thierry Mesana ◽  
Buu Khanh Lam

Sign in / Sign up

Export Citation Format

Share Document