Minimum discard volume to obtain reliable activated clotting time from the heparinized arterial line

2012 ◽  
Vol 20 (4) ◽  
pp. 794-798
Author(s):  
İsmail Aydın Erden
Perfusion ◽  
2021 ◽  
pp. 026765912110493
Author(s):  
Roland F Hoffmann ◽  
Sandra Horsten ◽  
Massimo A Mariani ◽  
Adrianus J de Vries

Introduction: The Activated Clotting Time (ACT) is commonly used to manage anticoagulation during cardiac surgery. The aim of this study was to compare the older manually operated Hemochron® Response and the automated Hemochron® Signature Elite. Methods: In this observational study the clinically relevant differences of both devices were investigated simultaneously, using duplicate measurements, in 29 patients who underwent a Coronary Artery Bypass Grafting (CABG) or Aortic Valve Replacement (AVR) in order to determine reliability, bias, and to detect which method has the lowest variation. Blood samples were obtained from the arterial line prior to surgery, after administration of 300 IU/kg heparin, 5 minutes after initiation of cardiopulmonary bypass and successively every 30 minutes, and after protamine administration. Results: A total of 202 measurements were performed. Of these 10 measurements were out of range in the Response and 9 in the Elite. About 27 single unstable magnet errors were seen in the Response versus no measurement errors in the Elite. No statistically significant differences between the Response (p = 0.22, Wilcoxon rank) and Elite (p = 0.064) duplicates were observed. The Response values were consistently higher during heparinization than the Elite measurements (p = 0.002, repeated measurements) with an average positive bias of around 56 seconds during heparinization (Bland-Altman). Overall, the coefficient of variation (CoV) increased during heparinization. Conclusion: The Elite was more reliable, but the variation was higher for the Elite than the Response. The observed positive bias in the Response compared to the Elite could affect heparin administration during surgery making the two systems not interchangeable.


2021 ◽  
Vol 30 ◽  
pp. S219
Author(s):  
J. Ramnarain ◽  
H. Rashid ◽  
C. Dowling ◽  
J. Ramzy ◽  
R. Gooley

Angiology ◽  
2021 ◽  
pp. 000331972199223
Author(s):  
Jacqueline H. Morris ◽  
Junsoo Alex Lee ◽  
Scott McNitt ◽  
Ilan Goldenberg ◽  
Craig R. Narins

The activated clotting time (ACT) assay is used to monitor and titrate anticoagulation therapy with unfractionated heparin during percutaneous coronary intervention (PCI). Observations at our institution suggested a considerable difference between ACT values drawn from varying arterial sites, prompting the current study. Patients undergoing PCI with unfractionated heparin therapy were prospectively enrolled. Simultaneous arterial blood samples were drawn from the access sheath and the coronary guide catheter. Differences between Hemochron ACT values were determined, and potential interactions with clinical variables were analyzed. Immediately postprocedure, the simultaneous mean guide and sheath ACTs were 327 ± 62 seconds and 257 ± 44 seconds, respectively, with a mean difference of 70 ± 60 seconds (P < .001). Nearly all (90%) ACT values obtained via the guide catheter were higher than the concurrent ACT drawn from the sheath. Logistic regression analysis demonstrated that lower weight-adjusted heparin doses and absence of diabetes were associated with a greater difference between the ACT values. We conclude that the ACT value is substantially greater when assessed via the guide catheter versus the access sheath. Although the biological mechanisms require further study, this difference should be considered when managing anticoagulation during PCI and when reporting ACT as part of research protocols.


Sign in / Sign up

Export Citation Format

Share Document