response versus
Recently Published Documents


TOTAL DOCUMENTS

178
(FIVE YEARS 40)

H-INDEX

20
(FIVE YEARS 2)

Biosensors ◽  
2021 ◽  
Vol 12 (1) ◽  
pp. 8
Author(s):  
Natalia M. Shmidt ◽  
Alexander S. Usikov ◽  
Evgeniia I. Shabunina ◽  
Alexey V. Nashchekin ◽  
Ekaterina V. Gushchina ◽  
...  

In this study, we discuss the mechanisms behind changes in the conductivity, low-frequency noise, and surface morphology of biosensor chips based on graphene films on SiC substrates during the main stages of the creation of biosensors for detecting influenza viruses. The formation of phenylamine groups and a change in graphene nano-arrangement during functionalization causes an increase in defectiveness and conductivity. Functionalization leads to the formation of large hexagonal honeycomb-like defects up to 500 nm, the concentration of which is affected by the number of bilayer or multilayer inclusions in graphene. The chips fabricated allowed us to detect the influenza viruses in a concentration range of 10−16 g/mL to 10−10 g/mL in PBS (phosphate buffered saline). Atomic force microscopy (AFM) and scanning electron microscopy (SEM) revealed that these defects are responsible for the inhomogeneous aggregation of antibodies and influenza viruses over the functionalized graphene surface. Non-uniform aggregation is responsible for a weak non-linear logarithmic dependence of the biosensor response versus the virus concentration in PBS. This feature of graphene nano-arrangement affects the reliability of detection of extremely low virus concentrations at the early stages of disease.


Entropy ◽  
2021 ◽  
Vol 23 (12) ◽  
pp. 1684
Author(s):  
Ting-Li Chen ◽  
Elizabeth P. Chou ◽  
Hsieh Fushing

Without assuming any functional or distributional structure, we select collections of major factors embedded within response-versus-covariate (Re-Co) dynamics via selection criteria [C1: confirmable] and [C2: irrepaceable], which are based on information theoretic measurements. The two criteria are constructed based on the computing paradigm called Categorical Exploratory Data Analysis (CEDA) and linked to Wiener–Granger causality. All the information theoretical measurements, including conditional mutual information and entropy, are evaluated through the contingency table platform, which primarily rests on the categorical nature within all involved features of any data types: quantitative or qualitative. Our selection task identifies one chief collection, together with several secondary collections of major factors of various orders underlying the targeted Re-Co dynamics. Each selected collection is checked with algorithmically computed reliability against the finite sample phenomenon, and so is each member’s major factor individually. The developments of our selection protocol are illustrated in detail through two experimental examples: a simple one and a complex one. We then apply this protocol on two data sets pertaining to two somewhat related but distinct pitching dynamics of two pitch types: slider and fastball. In particular, we refer to a specific Major League Baseball (MLB) pitcher and we consider data of multiple seasons.


Perfusion ◽  
2021 ◽  
pp. 026765912110493
Author(s):  
Roland F Hoffmann ◽  
Sandra Horsten ◽  
Massimo A Mariani ◽  
Adrianus J de Vries

Introduction: The Activated Clotting Time (ACT) is commonly used to manage anticoagulation during cardiac surgery. The aim of this study was to compare the older manually operated Hemochron® Response and the automated Hemochron® Signature Elite. Methods: In this observational study the clinically relevant differences of both devices were investigated simultaneously, using duplicate measurements, in 29 patients who underwent a Coronary Artery Bypass Grafting (CABG) or Aortic Valve Replacement (AVR) in order to determine reliability, bias, and to detect which method has the lowest variation. Blood samples were obtained from the arterial line prior to surgery, after administration of 300 IU/kg heparin, 5 minutes after initiation of cardiopulmonary bypass and successively every 30 minutes, and after protamine administration. Results: A total of 202 measurements were performed. Of these 10 measurements were out of range in the Response and 9 in the Elite. About 27 single unstable magnet errors were seen in the Response versus no measurement errors in the Elite. No statistically significant differences between the Response (p = 0.22, Wilcoxon rank) and Elite (p = 0.064) duplicates were observed. The Response values were consistently higher during heparinization than the Elite measurements (p = 0.002, repeated measurements) with an average positive bias of around 56 seconds during heparinization (Bland-Altman). Overall, the coefficient of variation (CoV) increased during heparinization. Conclusion: The Elite was more reliable, but the variation was higher for the Elite than the Response. The observed positive bias in the Response compared to the Elite could affect heparin administration during surgery making the two systems not interchangeable.


2021 ◽  
Vol 13 (19) ◽  
pp. 3917
Author(s):  
Carlos L. Pérez Díaz ◽  
Xiaoxiong Xiong ◽  
Yonghong Li ◽  
Kwofu Chiang

The Visible Infrared Imaging Radiometer Suite (VIIRS) onboard the Suomi National Polar-orbiting Partnership Program (S-NPP) satellite, launched in late 2011, has reached the decade landmark under successful operations. VIIRS has 22 spectral bands, 7 of which are thermal emissive bands (TEB) that cover the 3.70 to 11.84 μm wavelength range. Over the years, VIIRS TEB observations have been used to generate several data products (e.g., surface/cloud/atmospheric temperatures, cloud top altitude, and water vapor properties). The VIIRS TEB calibration uses a quadratic algorithm and is referenced to an on-board blackbody with temperature measurements traceable to the National Institute of Standards and Technology standard. This manuscript provides an overview of the VIIRS instrument operations and TEB calibration activities and algorithms used in the level 1B data and describes the TEB on-orbit performance for S-NPP VIIRS. The 10-year on-orbit performance of the S-NPP VIIRS TEB has generally been stable, and the degradations in the S-NPP TEB detector responses are minor after a decade in orbit. The noise characterization performance repeatedly meets the design requirements for all TEB detectors as well. On-orbit changes in the TEB response-versus-scan-angle, based on pitch maneuver observations, have been demonstrated to be extremely small. Moreover, multiple time series over select ground targets have shown that the sensor’s on-orbit performance is quite stable.


Author(s):  
Friedhelm Struck ◽  
Patrick Schreiner ◽  
Eva Staschik ◽  
Karin Wochinz‐Richter ◽  
Sarah Schulz ◽  
...  

Biomedicines ◽  
2021 ◽  
Vol 9 (8) ◽  
pp. 972
Author(s):  
Federica Lessi ◽  
Marica Laurino ◽  
Cristina Papayannidis ◽  
Orsola Vitagliano ◽  
Francesco Grimaldi ◽  
...  

Data on the use of azacytidine and decitabine as salvage therapy for acute myeloid leukemia are limited. We retrospectively reviewed clinical records of 100 patients treated with hypomethylating agents (HMA) as salvage therapy in nine Italian institutions. A total of 24% of patients obtained a response to HMA (CR, PR, or CRi), while 26% showed a stable disease (SD); 50% of patients experienced progressive disease. Median OS was 6.5 months. OS in patients with de novo AML was 6.1 months, while OS in patients with secondary AML (sAML) was 12.3 months (p = 0.037). Median OS after HMA in patients with SD as best response to HMA was similar to median OS in patients with response to HMA (10.6 months vs. 13 months). On multivariate analysis, OS difference between patients who obtained a response versus patients who did not was significant (p = 0.0037). OS difference in sAML was significantly better than in de novo AML (p < 0.00001). HMA showed a remarkable efficacy in terms of response rate and OS in a subgroup of patients (sAMLs), historically characterized by a poor outcome. Therefore, 5Azacitidine and decitabine may represent a good clinical option in a selected patient population with relapsed or refractory AML, unsuitable for allo-HSCT.


Author(s):  
Jeffrey McIntire ◽  
David I. Moyer ◽  
Amit Angal ◽  
Xiaoxiong Xiong

2021 ◽  
Author(s):  
Krista Marrero ◽  
Krithiga Aruljothi ◽  
Behzad Zareian ◽  
Chengchun Gao ◽  
Zhaoran Zhang ◽  
...  

Spontaneous neuronal activity strongly impacts stimulus encoding and behavioral responses. We sought to determine the effects of neocortical prestimulus activity on stimulus detection. We trained mice in a selective whisker detection task, in which they learned to respond (lick) to target stimuli in one whisker field and ignore distractor stimuli in the contralateral whisker field. During expert task performance, we used widefield Ca2+ imaging to assess prestimulus and post-stimulus neuronal activity broadly across frontal and parietal cortices. We found that lower prestimulus activity correlated with enhanced stimulus detection: lower prestimulus activity predicted response versus no response outcomes and faster reaction times. The activity predictive of trial outcome was distributed through dorsal neocortex, rather than being restricted to whisker or licking regions. Using principal component analysis, we demonstrate that response trials are associated with a distinct and less variable prestimulus neuronal subspace. For single units, prestimulus choice probability was weak yet distributed broadly, with lower than chance choice probability correlating with stronger sensory and motor encoding. These findings support a low amplitude, low variability, optimal prestimulus cortical state for stimulus detection that presents globally and predicts response outcomes for both target and distractor stimuli.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Yun-Jie Xu ◽  
Muhammad Bilal ◽  
Qasem Al-Mdallal ◽  
Muhammad Altaf Khan ◽  
Taseer Muhammad

AbstractThe present study explores incompressible, steady power law nanoliquid comprising gyrotactic microorganisms flow across parallel plates with energy transfer. In which only one plate is moving concerning another at a time. Nonlinear partial differential equations have been used to model the problem. Using Liao's transformation, the framework of PDEs is simplified to a system of Ordinary Differential Equations (ODEs). The problem is numerically solved using the parametric continuation method (PCM). The obtained results are compared to the boundary value solver (bvp4c) method for validity reasons. It has been observed that both the results are in best settlement with each other. The temperature, velocity, concentration and microorganism profile trend versus several physical constraints are presented graphically and briefly discussed. The velocity profile shows positive response versus the rising values of buoyancy convection parameters. While the velocity reduces with the increasing effect of magnetic field, because magnetic impact generates Lorentz force, which reduces the fluid velocity.


Sign in / Sign up

Export Citation Format

Share Document