Development and Validation of Analytical Method by RP-HPLC and Forced Degradation Studies of Tioconazole Drug

2019 ◽  
Vol 9 (4) ◽  
pp. 229
Author(s):  
Sunita N Surse ◽  
Sushil D Patil ◽  
Kunal R Deshmukh ◽  
Sanjay J Kshirsagar
Author(s):  
Patel Seema A. ◽  
Sayyed Nazifa S. ◽  
Lajporiya Mobina I. ◽  
Manjra Mehfuza U. ◽  
Aejaz Ahmed ◽  
...  

Aims: To develop and validate a new, simple, rapid, precise, and accurate An Eco-friendly RP-HPLC and UV-Method Development and Validation for an estimation of Tolvaptan in Bulk and Tablet dosage form followed by Forced Degradation Studies Place and Duration of the Study: The present work has been carried out at Ali-Allana College of Pharmacy, Akkalkuwa between November-2020 to April-2021. Methodology: The UV-Spectroscopic method was developed for the estimation of tolvaptan in bulk and tablet dosage form. The solvent selected for the tolvaptan UV analysis was 4% aq. SLS solution, the solution of 10µg/ml was scanned in UV region from 200-400 nm and the λmax value was determined. The RP-HPLC method was developed on Sunsil C18 150 mm x 4.6mm x 5μ column using acetonitrile: water [45:55] as mobile phase at flow rate 1.0 ml/min and UV detection at 266 nm. Results: The maximum absorbance was observed at 266 nm. The wavelength 266 nm was selected for further analysis of tolvaptan. The calibration curve was determined using drug concentrations ranging from 20-100 µgm/ml. The system suitability was performed by injecting a standard solution containing 200µg/ml of tolvaptan in six replicates. For two of them, the peak asymmetric were <1.5 and the theoretical plate number was >2000, and the %RSD of tolvaptan was less than 2. Conclusion: From the above results, it was concluded that the developed UV and RP-HPLC methods are precise and accurate and can be applied for the quantitative estimation of tolvaptan from bulk and tablet dosage forms. The method can be used for routine testing of tolvaptan by the pharmaceutical industry. Validation of the developed method was done as per International Conference on Harmonization (ICH) Q2R1 guidelines.


2021 ◽  
Author(s):  
Abderrazaq Hamdache ◽  
Lamia Grib ◽  
Celia Grib ◽  
Lydia Adour ◽  
Hakim Zatout ◽  
...  

2017 ◽  
Vol 9 (5) ◽  
pp. 121 ◽  
Author(s):  
Hemant K. Jain ◽  
Archana A. Gunjal

Objective: To develop an accurate, simple, precise and specific stability indicating RP-HPLC method for estimation of dimethyl fumarate in bulk and capsules.Methods: An Inertsil ODS (150x4.6 mm, 5µ) column and a mobile phase containing acetonitrile: potassium dihydrogen phosphate buffer pH 6.8 (50:50% v/v) was used for this study. The flow rate was maintained at 1.0 ml/min; column temperature was fixed at 35 °C and UV detection was carried out at 210 nm. The forced degradation studies were performed and method was validated with as per ICH guidelines.Results: The retention time of dimethyl fumarate was found to be 3.3±0.02 min. The value of correlation coefficient between peak area and concentration was found to be 0.9993. The mean percent recovery of dimethyl fumarate in capsules was found in the range of 99.65 to 101.64%. The results of forced degradation studies indicated that the drug was found to be stable in basic, oxidative and thermal conditions while degraded in acidic conditions.Conclusion: It can be conducted from results that the developed HPLC method is simple, accurate, precise and specific. Results of stress testing study revealed that the method is stability indicating. Thus, this method can be used for routine analysis of dimethyl fumarate capsules and check their stability.  


Sign in / Sign up

Export Citation Format

Share Document