scholarly journals Initial experience with Edwards SAPIEN valve transcatheter implantation in native RVOT in Latvia

2020 ◽  
Vol 27 (1) ◽  
pp. 10-16
Author(s):  
Luize Auzina ◽  
Inguna Lubaua ◽  
Elina Ligere ◽  
Inga Lace ◽  
Inta Bergmane ◽  
...  

Transcatheter pulmonary valve implantation has been a well-known method for more than a decade, but there are still many challenging cases when a personalized solution is needed. We report a case of a 15-year-old female patient with tetralogy of Fallot, who underwent a surgical correction during infancy. Because of progressive pulmonary regurgitation, stenosis, and right ventricle dilatation, transcatheter pulmonary valve implantation in the native right ventricle outflow tract (RVOT) using Edwards SAPIEN valve was performed. A “landing zone” was created prior to the intervention of stenting the RVOT and the right pulmonary artery. The transcatheter approach for pulmonary valve replacement in a native RVOT is a reasonable alternative to the surgical approach.

2018 ◽  
Vol 28 (10) ◽  
pp. 1168-1170 ◽  
Author(s):  
Alessia Faccini ◽  
Massimo Chessa ◽  
Mansour Aljoufan

AbstractPercutaneous pulmonary valve implantation is increasingly adopted as an alternative procedure to surgery in dysfunctional homograft, and in patients with “native” or wide right ventricle outflow tract dysfunction. Pre-stenting is mandatory in this category of patients for many reasons, one of which is to create an adequate landing zone for the bioprosthesis. Here we report on a tricky situation that occurred during pre-stenting, and we describe how we successfully overcame it.


2021 ◽  
Vol 5 (7) ◽  
Author(s):  
Giuseppe Tarantini ◽  
Mauro Massussi ◽  
Luca Nai Fovino ◽  
Domenico Sirico ◽  
Biagio Castaldi

Abstract Background Transcatheter pulmonary valve implantation (TPVI) is an effective treatment for right ventricular outflow tract (RVOT) dysfunction. Patients affected by congenital heart disease requiring TPVI may have difficult anatomies, thus making the intervention technically demanding. Case summary We report a case series of two patients affected by RVOT dysfunction. Both the cases were characterized by difficulty to advance the valve over the wire, which was successfully overcome by the application of the snared wire technique (SWT) to TPVI. Discussion Various technical pitfalls and tips have been described to facilitate the delivery of the transcatheter Edwards Sapien valve in the pulmonary position. The SWT described by the authors may be a helpful tool to gain supportiveness and stability of the guidewire during the procedure.


Author(s):  
Anja Hanser ◽  
Jörg Michel ◽  
Andreas Hornung ◽  
Ludger Sieverding ◽  
Michael Hofbeck

AbstractOne of the major obstacles preventing successful percutaneous pulmonary valve implantation (PPVI) is related to the close proximity of coronary artery branches to the expected landing zone. The aim of this study was to assess the frequency of coronary artery anomalies (CAAs) especially those associated with major coronary branches crossing the right ventricular outflow tract (RVOT) and to describe their relevance for the feasibility of percutaneous pulmonary valve implantation (PPVI). In our retrospective single-center study 90 patients were evaluated who underwent invasive testing for PPVI in our institution from 1/2010 to 1/2020. CAAs were identified in seven patients (8%) associated with major branches crossing the RVOT due to origin of the left anterior descending (LAD) or a single coronary artery from the right aortic sinus. In 5/7 patients with CAAs balloon testing of the RVOT and selective coronary angiographies revealed a sufficiently large landing zone distal to the coronary artery branch. While unfavorable RVOT dimensions prevented PPVI in one, PPVI was performed successfully in the remaining four patients. The relatively short landing zone required application of the “folded” melody technique in two patients. All patients are doing well (mean follow-up 3 years). CAAs associated with major coronary branches crossing the RVOT can be expected in about 8% of patients who are potential candidates for PPVI. Since the LAD crossed the RVOT below the plane of the pulmonary valve successful distal implantation of the valve was possible in 4/7 patients. Therefore these coronary anomalies should not be considered as primary contraindications for PPVI.


2016 ◽  
Vol 8 (5) ◽  
pp. 639-642 ◽  
Author(s):  
Patcharapong Suntharos ◽  
Lourdes R. Prieto

Percutaneous pulmonary valve implantation is now an acceptable treatment option. The Edwards SAPIEN valve, intended for transcatheter aortic valve implantation, has been used in patients whose landing zone diameter is >22 to 24 mm which is not suitable for Melody valve. We report a patient in whom we successfully placed the latest generation, Edwards SAPIEN 3 (ES3) in the pulmonary position. However, because of the short covered portion of this valve, there was a significant paravalvular leak through the stent struts requiring implantation of a second ES3 valve.


2020 ◽  
Vol 28 (1) ◽  
pp. 1-6
Author(s):  
Fatema Nurun Nahar ◽  
Jufan Mansur Al ◽  
Shubert Stephan ◽  
Hossain Mir Mahmud

INTRODUCTION Incidence of congenital heart disease is 25 per thousand live birth in Bangladesh which is much higher than other countries. Tetralogy of Fallot, the commonest cyanotic heart disease (5%) and some other complex diseases with right ventricular outflow tract abnormality demand surgical correction and revision in many occasions including percutaneous intervention. As a resource constraint country, it was a difficult task to introduce percutaneous pulmonary valve implantation (PPVI) with MelodyTM. However, it was started on 12th December 2012 in Combined Military Hospital Dhaka, Bangladesh and cases performed till October 2019 were included in this series. METHODS Retrospective analysis of six cases who had PPVI with MelodyTM in Combined Military Hospital, Bangladesh. Patient with dysfunctional conduit between right ventricle (RV) and pulmonary artery causing (a) Symptoms of exceptional dyspnoea of various grade (NYHA II,III, IV) (b) RVEVD >150 ml/m2 ±regurgitant fraction >40% (c) RVOT peak instantaneous gradient > 30 mm Hg. (d) RV dysfunction (RVEF<40%) were accepted for the procedure and outcome were analyzed. RESULTS Mean age was 9.56 ± 2.96 years, weight was 28.75 ± 8.61 kg, height was 137.5 ± 17.52 cm. Mean age at surgery was 4.25 ± 2.72 years. Female were 66.66%. Aortic homograft was used in 66.66% cases. Eighteen mm Ensemble was used in four (66.66%) cases and 20 mm and 22 mm in one each. Immediate result was excellent with no residual PS in two cases and negligible residual flow acceleration across pulmonary valve in four cases. No PR seen in all except one. One patient developed Bacterial endocarditis after 3 years and was treated. CONCLUSION Aim of PPVI is to prolong the life expectancy of conduits which were placed surgically from right ventricle to pulmonary artery. In our case series, we found that Melody valve is functioning well without any complications like infective endocarditis or stent fracture. KEYWORDS PPVI, MelodyTM, RVOT, Outcome