scholarly journals Primary Total Hip Arthroplasty Using an Uncemented Wagner SL Stem in Elderly Patients With Dorr Type C Femoral Bone

2018 ◽  
Vol 103 (5-6) ◽  
pp. 287-294
Author(s):  
Ping Zhen ◽  
Jun Liu ◽  
Hao Lu ◽  
Hui Chen ◽  
Xusheng Li ◽  
...  

The purpose of this study was to review retrospectively the primary total hip arthroplasties operated upon with the cementless Wagner self-locking stem in patients with Type C femoral bone. Twenty-five total hip arthroplasties were performed in 23 patients aged ≥60 years using a cementless Wagner self-locking femoral component between 2006 and 2011. According to Dorr's criteria, all 25 femora were classified as type C bone. Mean follow-up period was 62 months (range, 47–85 months). Average Harris Hip score preoperatively was 46 ± 9 (range, 39–62) and at the last follow-up was 90 ± 9 (range, 83–98). The mean proximal stem-to-canal fill percentage was 95% ± 3.5% (anteroposterior view) and 90% ± 2.8% (lateral view) and the mean distal canal fill was 93% ± 4.5% (anteroposterior) and 92% ± 3.9% (lateral). Radiographic evaluation demonstrated good osteointegration of the implants in follow-up. Based on the long-straight cylindrical tapered stem design, the cementless Wagner SL stem can achieve reliable stability by close apposition of stem and wide stovepipe femoral canal from metaphysis to diaphysis in Type C bone.

Author(s):  
Ping Zhen ◽  
Jun Liu ◽  
Xusheng Li ◽  
Hao Lu ◽  
Shenghu Zhou

Abstract Background The purpose of this study was to review retrospectively the primary total hip arthroplasties operated upon with the cementless Wagner Self-Locking stem in patients with type C femoral bone. Methods Twenty-eight total hip arthroplasties were performed in 25 patients aged ≥ 60 years using a cementless Wagner Self-Locking femoral component between 2006 and 2011. According to Dorr’s criteria, all 28 femora were classified as type C bone. All patients were treated with THA using a cementless Wagner cone prosthesis. Clinical and radiologic evaluations were performed on all patients. Results Mean follow-up period was 125 ± 10.5 months (range 96 to 156 months). Average Harris hip score pre-operatively was 46 ± 9 (range 39 to 62) and at the last follow-up was 90 ± 9 (range 83 to 98). The stem to canal fill is calculated as percentages on the operative side at three distinct levels: just below the lesser trochanter, at midstem, and 1 cm above the tip of the component on anteroposterior radiograph. The mean proximal stem-to-canal fill percentages were 97% ± 2.1%, 95% ± 3.5%, and 88% ± 2.6%, respectively (anteroposterior view) and 92% ± 2.2%, 86% ± 1.9%, and 83% ± 2.5%, respectively (lateral view). Radiographic evaluation demonstrated good osteointegration of the implants in the follow-up. Conclusions Based on the long-straight cylindrical tapered stem design, the cementless Wagner SL stem can achieve reliable stability by close apposition of the stem and wide stovepipe femoral canal from metaphysis to diaphysis in type C bone.


2020 ◽  
Author(s):  
Ping Zhen ◽  
Yanfeng Chang ◽  
Heng Yue ◽  
Hui Chen ◽  
Shenghu Zhou ◽  
...  

Abstract Background: Dorr Type C femoral bone exhibits a wide, stovepipe-shaped femoral canal and thin cortices in the proximal femur. Dorr C bone combined with severe osteoporosis is an important challenge in primary hip arthroplasty. In this study, we assessed the effects of short metaphyseal fitting cementless stems on preformatted primary total hip arthroplasties in young adult osteoporotic patients with this femoral presentation.Methods: A total of 42 hip arthroplasties were performed in 35 young patients (range, 20 to 36 years) using a short Tri-lock bone preservation metaphyseal-fitting cementless femoral component between 2012 and 2017. The mean age at surgery of the 27 male (33 hips) and 8 female (9 hips) patients was 27.5 ± 3.7 years (range 20.3 to 35.8 years). The mean body mass index (BMI) was 20.2 kg/m2 (range, 16.8–23.2 kg/m2). According to Dorr’s criteria, all 42 femora were classified as type C bone and all femurs suffered from severe osteoporosis (Singh index≤3). Results: The mean follow-up period was 5.5 ± 1.1 years (range, 3.0–8.0 years). The clinical and functional results improved for the Harris hip score, WOMAC, and UCLA activity scores. The Harris Hip score improved from 48.0 ± 8.0 (range 38.0 to 61.0) preoperatively to 87.0 ± 9.0 (range 77.0 to 92.0) at 12 months after surgery and 91.0 ± 8.0 (range 85.0 to 98.0) at final follow-up. The preoperative UCLA activity score was 3.0±0.5 points (range, 1.0–4.0 points), which significantly improved to 7.5±0.7 points (range, 6.0–8.0 points) at the final follow-up. No patient exhibited thigh pain at the final follow-up. The mean stem-to-canal fill percentages were 97% ± 2.1% (anteroposterior view at midstem). For stem alignment, 40 hips (95.2%) of the femoral stem were positioned neutral to 3° of varus with reference to the femoral shaft axis. The remaining two were positioned at 4° varus to 4° valgus. Radiographic evaluation showed good osteointegration of the implants in follow-up.Conclusions: Based on the tapered-wedge design and proximal porous coating, the shortened tapered conventional stem can achieve reliable stability through neck filling and metaphyseal fixation, which does not depend on the isthmus hoop stress. This stem was suitable in severe osteoporotic patients with Type C bones in young adults who presented with a correspondingly straightened femoral canal with a wide isthmus and thin cortex.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Ping Zhen ◽  
Yanfeng Chang ◽  
Heng Yue ◽  
Hui Chen ◽  
Shenghu Zhou ◽  
...  

Abstract Background Dorr type C femoral bone exhibits a wide, stovepipe-shaped femoral canal, and thin cortices in the proximal femur. Dorr C bone combined with severe osteoporosis is an important challenge in primary hip arthroplasty. In this study, we assessed the effects of short metaphyseal fitting cementless stems on preformatted primary total hip arthroplasties in young adult osteoporotic patients with this femoral presentation. Methods A total of 42 hip arthroplasties were performed in 35 young patients (range 20 to 36 years) using a short Tri-lock bone preservation metaphyseal-fitting cementless femoral component between 2012 and 2017. The mean age at surgery of the 27 male (33 hips) and 8 female (9 hips) patients was 27.5 years (range 20.3 to 35.8 years). The mean body mass index (BMI) was 20.2 kg/m2 (range, 16.8–23.2 kg/m2). According to Dorr’s criteria, all 42 femora were classified as type C bone and all femurs suffered from severe osteoporosis (Singh index ≤ 3). Results The mean follow-up period was 5.5 years (range 3.0 to 8.0 years). The clinical and functional results improved for the Harris hip score, WOMAC, and UCLA activity scores. The Harris Hip score improved from 48.0 ± 8.0 (range 38.0 to 61.0) preoperatively to 87.0 ± 9.0 (range 77.0 to 92.0) at 12 months after surgery and 91.0 ± 8.0 (range 85.0 to 98.0) at final follow-up. The preoperative UCLA activity score was 3.0 ± 0.5 points (range, 1.0–4.0 points), which significantly improved to 7.5 ± 0.7 points (range 6.0 to 8.0 points) at the final follow-up. No patient exhibited thigh pain at the final follow-up. The mean stem-to-canal fill percentages were 97% ± 2.1% (anteroposterior view at midstem). For stem alignment, 40 hips (95.2%) of the femoral stem were positioned neutrally to 3° of varus with reference to the femoral shaft axis. The remaining two were positioned at 4° varus to 4° valgus. Radiographic evaluation showed good osteointegration of the implants in follow-up. Conclusions Based on the tapered-wedge design and proximal porous coating, the shortened tapered conventional stem can achieve reliable stability through neck filling and metaphyseal fixation, which does not depend on the isthmus hoop stress. This stem was suitable in severe osteoporotic patients with type C bones in young adults who presented with a correspondingly straightened femoral canal with a wide isthmus and thin cortex.


2020 ◽  
Author(s):  
Ping Zhen ◽  
Yanfeng Chang ◽  
Heng Yue ◽  
Hui Chen ◽  
Shenghu Zhou ◽  
...  

Abstract BackgroundDorr Type C femoral bone exhibits a wide, stovepipe-shaped femoral canal and thin cortices in the proximal femur. Dorr C bone combined with severe osteoporosis is an important challenge in primary hip arthroplasty. In this study, we assessed the effects of short metaphyseal fitting cementless stems on preformatted primary total hip arthroplasties in young adult osteoporotic patients with this femoral presentation.MethodsA total of 42 hip arthroplasties were performed in 35 young patients (range 20 to 36 years) using a short Tri-lock bone preservation metaphyseal-fitting cementless femoral component between 2012 and 2017. The mean age at surgery of the 27 male (33 hips) and 8 female (9 hips) patients was 27.5 years (range 20.3 to 35.8 years). The mean body mass index (BMI) was 20.2 kg/m 2 (range, 16.8-23.2 kg/m 2 ). According to Dorr’s criteria, all 42 femora were classified as type C bone and all femurs suffered from severe osteoporosis (Singh index≤3).ResultsThe mean follow-up period was 5.5 years (range 3.0 to 8.0 years). The clinical and functional results improved for the Harris hip score, WOMAC, and UCLA activity scores. The Harris Hip score improved from 48.0 ± 8.0 (range 38.0 to 61.0) preoperatively to 87.0 ± 9.0 (range 77.0 to 92.0) at 12 months after surgery and 91.0 ± 8.0 (range 85.0 to 98.0) at final follow-up. The preoperative UCLA activity score was 3.0 ± 0.5 points (range, 1.0-4.0 points), which significantly improved to 7.5 ± 0.7 points (range 6.0 to 8.0 points) at the final follow-up. No patient exhibited thigh pain at the final follow-up. The mean stem-to-canal fill percentages were 97% ± 2.1% (anteroposterior view at midstem). For stem alignment, 40 hips (95.2%) of the femoral stem were positioned neutrally to 3° of varus with reference to the femoral shaft axis. The remaining two were positioned at 4° varus to 4° valgus. Radiographic evaluation showed good osteointegration of the implants in follow-up.ConclusionsBased on the tapered-wedge design and proximal porous coating, the shortened tapered conventional stem can achieve reliable stability through neck filling and metaphyseal fixation, which does not depend on the isthmus hoop stress. This stem was suitable in severe osteoporotic patients with Type C bones in young adults who presented with a correspondingly straightened femoral canal with a wide isthmus and thin cortex.


2021 ◽  
Author(s):  
FIRAT OZAN ◽  
Murat Kahraman ◽  
Ali Baktır ◽  
Kürşat Gençer

Abstract Background: To evaluate the clinical features and results of the revision total hip arthroplasties (THA) in patients with catastrophic failures and metallosis. Methods: Fifteen hips of 14 patients with catastrophic failure and metallosis in hip arthroplasties were evaluated. They were followed for at least 4.2 years after the revision THA. Clinical evaluation was performed using Harris hip score. Osteolysis, loosening or presence of metallosis was evaluated with standard radiographs. Metallosis was evaluated intraoperatively according to the metallosis severity classification. Results: The mean time from failure until revision surgery was 9.4 years. It was observed that in the primary THA, metal-on-ceramic (MoC), ceramic-on-ceramic (CoC) and metal-on-conventional polyethylene (MoCPE) bearings were used in 1, 3 and 11 hips, respectively. Grade III metallosis was observed in all patients during revision surgeries. The mean Harris hip score increased from 55 points before revision THA to 75 points at the final follow-up. In revision arthroplasty, MoCPE and CoC bearings were used in 13 and 2 hips, respectively. The femoral stem was replaced in 5 hips. All acetabular cups, except that of one hip, were revised. Conclusions: Revisions of THAs with catastrophic failures and metallosis are quite challenging. Routine follow-up of arthroplasty patients is beneficial to examine for osteolysis, loosening, and asymmetric wear.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Fırat Ozan ◽  
Murat Kahraman ◽  
Ali Baktır ◽  
Kürşat Gençer

Abstract Background To evaluate the clinical features and results of the revision total hip arthroplasties (THA) in patients with catastrophic failures and metallosis. Methods Fifteen hips of 14 patients with catastrophic failure and metallosis in hip arthroplasties were evaluated. They were followed for at least 4.2 years after the revision THA. Clinical evaluation was performed using Harris hip score. Osteolysis, loosening or presence of metallosis was evaluated with standard radiographs. Metallosis was evaluated intraoperatively according to the metallosis severity classification. Results The mean time from failure until revision surgery was 9.4 years. It was observed that in the primary THA, metal-on-ceramic (MoC), ceramic-on-ceramic (CoC) and metal-on-conventional polyethylene (MoCPE) bearings were used in 1, 3 and 11 hips, respectively. Grade III metallosis was observed in all patients during revision surgeries. The mean Harris hip score increased from 55 points before revision THA to 75 points at the final follow-up. In revision arthroplasty, MoCPE and CoC bearings were used in 13 and 2 hips, respectively. The femoral stem was replaced in 5 hips. All acetabular cups, except that of one hip, were revised. Conclusions Revisions of THAs with catastrophic failures and metallosis are quite challenging. Routine follow-up of arthroplasty patients is beneficial to examine for osteolysis, loosening, and asymmetric wear.


Joints ◽  
2016 ◽  
Vol 04 (03) ◽  
pp. 134-141 ◽  
Author(s):  
Angelo Graceffa ◽  
Pier Indelli ◽  
Leonardo Latella ◽  
Paolo Poli ◽  
Alexander Fulco ◽  
...  

Purpose: historically, the original CLS Spotorno Stem has demonstrated excellent survival. The design of this stem was recently modified, resulting in the introduction of a shorter, modular version (CLS Brevius). The purpose of the current study was to evaluate the functional, radiological and survivorship outcomes of the cementless CLS Brevius Stem in a multi-surgeon, single center, consecutive series study at two years post-surgery. Methods: the Authors performed 170 total hip arthroplasties in 155 patients using the shorter, tripletaper stem design (CLS Brevius). The patients’ diagnoses were primary hip osteoarthritis (OA) in 74.4%, secondary hip OA in 22.6%, and post-traumatic hip OA in 3%. All operations were performed through a mini-posterior approach, with the patient in the lateral decubitus position. The mean follow-up was 32 months (24-44 months). Outcome was assessed using the Harris Hip Score (HHS). Results: the mean HHS improved from 32 preoperatively to 92 points at final follow-up, while the stem survival rate was 99.4%.Overall, the results were excellent in148 hips (87%), good in 14 hips (8.2%), fair in six hips (3.6%), and poor in two hips (1.2%). Intraoperative complications included a calcar fissure in three hips (1.7%). Correct femoral offset was reproduced in 97% while the planned center of hip rotation was achieved in 98%. Only one hip underwent early stem revision; this was due to major subsidence. Conclusions: the modified CLS stem design showed excellent short-term results with a low rate of early postoperative complications. One of the main findings of this study was the high correlation between the planned femoral offset and center of hip rotation and the final radiographic measurements. This high reproducibility, which indicates the ability of the system to restore normal hip anatomy, is indeed due to the extensive modularity that characterizes this stem system. Long-term follow-up studies are necessary to fully compare the outcomes of the new design with its highly successful predecessor. Level of Evidence: Level IV, therapeutic cases series.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Loris Perticarini ◽  
Stefano Marco Paolo Rossi ◽  
Alberto Fioruzzi ◽  
Eugenio Jannelli ◽  
Mario Mosconi ◽  
...  

Abstract Background The aim of this paper is to evaluate the clinical and radiological outcomes of a fluted tapered modular distal-fixation stem at medium to long-term follow-up. The hypothesis of this investigation was to verify if the use of this implant design may have provided potential advantages in femoral revisions and post-traumatic instances where the restoration of the anatomy was the prime concern. Methods We retrospectively reviewed 62 cases of femoral revision surgeries, performed in Paprosky type IIIA and IIIB bone defects between January 2001 and December 2011 with a mean follow-up of 8.5 ± 1.5 years (range 5.1–15.9 years) where a modular fluted stem was used. The clinical assessment was performed with the Harris Hip Score (HHS), and the radiographic evaluation was carried in order to assess the stability of the femoral component. Intra-operative and postoperative complications were recorded, and the rates of complications and revisions for any cause were determined. Results Mean HHS improved 35.4 points from the preoperative assessment. Radiographic evaluation showed a stable stem anchorage in 90.3% of the cases at the last follow-up. Five (8%) implants required additional surgery. Neither breakage of the stem nor loosening of the taper junction were recorded. Kaplan-Meier survivorship was 89.4% (CI: 88.8–90%) for any complication and 92.3% (CI: 91.8–92.7%) according to revision for any causes at 81 months follow-up. Conclusions Our findings suggest that this stem design is a reliable option in cases of complex femoral bone defects, as well as in cases with high functional deficiencies, with promising survivorship.


2019 ◽  
Vol 101-B (5) ◽  
pp. 502-511 ◽  
Author(s):  
S. Lidder ◽  
D. J. Epstein ◽  
G. Scott

Aims Short-stemmed femoral implants have been used for total hip arthroplasty (THA) in young and active patients to conserve bone, provide physiological loading, and reduce the incidence of thigh pain. Only short- to mid-term results have been presented and there have been concerns regarding component malalignment, incorrect sizing, and subsidence. This systematic review reports clinical and radiological outcomes, complications, revision rates, and implant survival in THA using short-stemmed femoral components. Materials and Methods A literature review was performed using the EMBASE, Medline, and Cochrane databases. Strict inclusion and exclusion criteria were used to identify studies reporting clinical and radiological follow-up for short-stemmed hip arthroplasties. Results A total of 28 studies were eligible for inclusion. This included 5322 hips in 4657 patients with a mean age of 59 years (13 to 94). The mean follow-up was 6.1 years (0.5 to 20). The mean Harris Hip Score improved from 46 (0 to 100) to 92 (39 to 100). The mean Oxford Hip Score improved from 25 (2 to 42.5) to 35 (12.4 to 48). The mean Western Ontario & McMaster Universities Osteoarthritis Index improved from 54 (2 to 95) to 22 (0 to 98). Components were aligned in a neutral coronal alignment in up to 90.9% of cases. A total of 15 studies reported component survivorship, which was 98.6% (92% to 100%) at a mean follow-up of 12.1 years. Conclusion Short-stemmed femoral implants show similar improvement in clinical and radiological outcomes compared with conventional length implants. Only mid-term survivorship, however, is known. An abundance of short components have been developed and used commercially without staged clinical trials. Long-term survival is still unknown for many of these components. There remains tension between innovation and the moral duty to ensure that the introduction of new implants is controlled until safety and patient benefit are demonstrated. Implant innovation and subsequent use should be driven by proven clinical outcomes, rather than market and financial forces, and ethical practice must be ensured. Cite this article: Bone Joint J 2019;101-B:502–511.


2021 ◽  
Vol 2 (12) ◽  
pp. 1035-1042
Author(s):  
Maciej Okowinski ◽  
Mette Holm Hjorth ◽  
Sebastian Breddam Mosegaard ◽  
Jonathan Hugo Jürgens-Lahnstein ◽  
Stig Storgaard Jakobsen ◽  
...  

Aims Femoral bone preparation using compaction technique has been shown to preserve bone and improve implant fixation in animal models. No long-term clinical outcomes are available. There are no significant long-term differences between compaction and broaching techniques for primary total hip arthroplasty (THA) in terms of migration, clinical, and radiological outcomes. Methods A total of 28 patients received one-stage bilateral primary THA with cementless femoral stems (56 hips). They were randomized to compaction on one femur and broaching on the contralateral femur. Overall, 13 patients were lost to the ten-year follow-up leaving 30 hips to be evaluated in terms of stem migration (using radiostereometry), radiological changes, Harris Hip Score, Oxford Hip Score, and complications. Results Over a mean follow-up period of 10.6 years, the mean stem subsidence was similar between groups, with a mean of -1.20 mm (95% confidence interval (CI) -2.28 to -0.12) in the broaching group and a mean of -0.73 mm (95% CI -1.65 to 0.20) in the compaction group (p = 0.07). The long-term migration patterns of all stems were similar. The clinical and radiological outcomes were similar between groups. There were two intraoperative fractures in the compaction group that were fixed with cable wire and healed without complications. No stems were revised. Conclusion Similar stem subsidence and radiological and clinical outcomes were identified after the use of compaction and broaching techniques of the femur at long-term follow-up. Only the compaction group had intraoperative periprosthetic femur fractures, but there were no long-term consequences of these. Cite this article: Bone Jt Open 2021;2(12):1035–1042.