A systematic review of short metaphyseal loading cementless stems in hip arthroplasty

2019 ◽  
Vol 101-B (5) ◽  
pp. 502-511 ◽  
Author(s):  
S. Lidder ◽  
D. J. Epstein ◽  
G. Scott

Aims Short-stemmed femoral implants have been used for total hip arthroplasty (THA) in young and active patients to conserve bone, provide physiological loading, and reduce the incidence of thigh pain. Only short- to mid-term results have been presented and there have been concerns regarding component malalignment, incorrect sizing, and subsidence. This systematic review reports clinical and radiological outcomes, complications, revision rates, and implant survival in THA using short-stemmed femoral components. Materials and Methods A literature review was performed using the EMBASE, Medline, and Cochrane databases. Strict inclusion and exclusion criteria were used to identify studies reporting clinical and radiological follow-up for short-stemmed hip arthroplasties. Results A total of 28 studies were eligible for inclusion. This included 5322 hips in 4657 patients with a mean age of 59 years (13 to 94). The mean follow-up was 6.1 years (0.5 to 20). The mean Harris Hip Score improved from 46 (0 to 100) to 92 (39 to 100). The mean Oxford Hip Score improved from 25 (2 to 42.5) to 35 (12.4 to 48). The mean Western Ontario & McMaster Universities Osteoarthritis Index improved from 54 (2 to 95) to 22 (0 to 98). Components were aligned in a neutral coronal alignment in up to 90.9% of cases. A total of 15 studies reported component survivorship, which was 98.6% (92% to 100%) at a mean follow-up of 12.1 years. Conclusion Short-stemmed femoral implants show similar improvement in clinical and radiological outcomes compared with conventional length implants. Only mid-term survivorship, however, is known. An abundance of short components have been developed and used commercially without staged clinical trials. Long-term survival is still unknown for many of these components. There remains tension between innovation and the moral duty to ensure that the introduction of new implants is controlled until safety and patient benefit are demonstrated. Implant innovation and subsequent use should be driven by proven clinical outcomes, rather than market and financial forces, and ethical practice must be ensured. Cite this article: Bone Joint J 2019;101-B:502–511.

2020 ◽  
Author(s):  
Ping Zhen ◽  
Yanfeng Chang ◽  
Heng Yue ◽  
Hui Chen ◽  
Shenghu Zhou ◽  
...  

Abstract Background: Dorr Type C femoral bone exhibits a wide, stovepipe-shaped femoral canal and thin cortices in the proximal femur. Dorr C bone combined with severe osteoporosis is an important challenge in primary hip arthroplasty. In this study, we assessed the effects of short metaphyseal fitting cementless stems on preformatted primary total hip arthroplasties in young adult osteoporotic patients with this femoral presentation.Methods: A total of 42 hip arthroplasties were performed in 35 young patients (range, 20 to 36 years) using a short Tri-lock bone preservation metaphyseal-fitting cementless femoral component between 2012 and 2017. The mean age at surgery of the 27 male (33 hips) and 8 female (9 hips) patients was 27.5 ± 3.7 years (range 20.3 to 35.8 years). The mean body mass index (BMI) was 20.2 kg/m2 (range, 16.8–23.2 kg/m2). According to Dorr’s criteria, all 42 femora were classified as type C bone and all femurs suffered from severe osteoporosis (Singh index≤3). Results: The mean follow-up period was 5.5 ± 1.1 years (range, 3.0–8.0 years). The clinical and functional results improved for the Harris hip score, WOMAC, and UCLA activity scores. The Harris Hip score improved from 48.0 ± 8.0 (range 38.0 to 61.0) preoperatively to 87.0 ± 9.0 (range 77.0 to 92.0) at 12 months after surgery and 91.0 ± 8.0 (range 85.0 to 98.0) at final follow-up. The preoperative UCLA activity score was 3.0±0.5 points (range, 1.0–4.0 points), which significantly improved to 7.5±0.7 points (range, 6.0–8.0 points) at the final follow-up. No patient exhibited thigh pain at the final follow-up. The mean stem-to-canal fill percentages were 97% ± 2.1% (anteroposterior view at midstem). For stem alignment, 40 hips (95.2%) of the femoral stem were positioned neutral to 3° of varus with reference to the femoral shaft axis. The remaining two were positioned at 4° varus to 4° valgus. Radiographic evaluation showed good osteointegration of the implants in follow-up.Conclusions: Based on the tapered-wedge design and proximal porous coating, the shortened tapered conventional stem can achieve reliable stability through neck filling and metaphyseal fixation, which does not depend on the isthmus hoop stress. This stem was suitable in severe osteoporotic patients with Type C bones in young adults who presented with a correspondingly straightened femoral canal with a wide isthmus and thin cortex.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Ping Zhen ◽  
Yanfeng Chang ◽  
Heng Yue ◽  
Hui Chen ◽  
Shenghu Zhou ◽  
...  

Abstract Background Dorr type C femoral bone exhibits a wide, stovepipe-shaped femoral canal, and thin cortices in the proximal femur. Dorr C bone combined with severe osteoporosis is an important challenge in primary hip arthroplasty. In this study, we assessed the effects of short metaphyseal fitting cementless stems on preformatted primary total hip arthroplasties in young adult osteoporotic patients with this femoral presentation. Methods A total of 42 hip arthroplasties were performed in 35 young patients (range 20 to 36 years) using a short Tri-lock bone preservation metaphyseal-fitting cementless femoral component between 2012 and 2017. The mean age at surgery of the 27 male (33 hips) and 8 female (9 hips) patients was 27.5 years (range 20.3 to 35.8 years). The mean body mass index (BMI) was 20.2 kg/m2 (range, 16.8–23.2 kg/m2). According to Dorr’s criteria, all 42 femora were classified as type C bone and all femurs suffered from severe osteoporosis (Singh index ≤ 3). Results The mean follow-up period was 5.5 years (range 3.0 to 8.0 years). The clinical and functional results improved for the Harris hip score, WOMAC, and UCLA activity scores. The Harris Hip score improved from 48.0 ± 8.0 (range 38.0 to 61.0) preoperatively to 87.0 ± 9.0 (range 77.0 to 92.0) at 12 months after surgery and 91.0 ± 8.0 (range 85.0 to 98.0) at final follow-up. The preoperative UCLA activity score was 3.0 ± 0.5 points (range, 1.0–4.0 points), which significantly improved to 7.5 ± 0.7 points (range 6.0 to 8.0 points) at the final follow-up. No patient exhibited thigh pain at the final follow-up. The mean stem-to-canal fill percentages were 97% ± 2.1% (anteroposterior view at midstem). For stem alignment, 40 hips (95.2%) of the femoral stem were positioned neutrally to 3° of varus with reference to the femoral shaft axis. The remaining two were positioned at 4° varus to 4° valgus. Radiographic evaluation showed good osteointegration of the implants in follow-up. Conclusions Based on the tapered-wedge design and proximal porous coating, the shortened tapered conventional stem can achieve reliable stability through neck filling and metaphyseal fixation, which does not depend on the isthmus hoop stress. This stem was suitable in severe osteoporotic patients with type C bones in young adults who presented with a correspondingly straightened femoral canal with a wide isthmus and thin cortex.


2020 ◽  
Author(s):  
Ping Zhen ◽  
Yanfeng Chang ◽  
Heng Yue ◽  
Hui Chen ◽  
Shenghu Zhou ◽  
...  

Abstract BackgroundDorr Type C femoral bone exhibits a wide, stovepipe-shaped femoral canal and thin cortices in the proximal femur. Dorr C bone combined with severe osteoporosis is an important challenge in primary hip arthroplasty. In this study, we assessed the effects of short metaphyseal fitting cementless stems on preformatted primary total hip arthroplasties in young adult osteoporotic patients with this femoral presentation.MethodsA total of 42 hip arthroplasties were performed in 35 young patients (range 20 to 36 years) using a short Tri-lock bone preservation metaphyseal-fitting cementless femoral component between 2012 and 2017. The mean age at surgery of the 27 male (33 hips) and 8 female (9 hips) patients was 27.5 years (range 20.3 to 35.8 years). The mean body mass index (BMI) was 20.2 kg/m 2 (range, 16.8-23.2 kg/m 2 ). According to Dorr’s criteria, all 42 femora were classified as type C bone and all femurs suffered from severe osteoporosis (Singh index≤3).ResultsThe mean follow-up period was 5.5 years (range 3.0 to 8.0 years). The clinical and functional results improved for the Harris hip score, WOMAC, and UCLA activity scores. The Harris Hip score improved from 48.0 ± 8.0 (range 38.0 to 61.0) preoperatively to 87.0 ± 9.0 (range 77.0 to 92.0) at 12 months after surgery and 91.0 ± 8.0 (range 85.0 to 98.0) at final follow-up. The preoperative UCLA activity score was 3.0 ± 0.5 points (range, 1.0-4.0 points), which significantly improved to 7.5 ± 0.7 points (range 6.0 to 8.0 points) at the final follow-up. No patient exhibited thigh pain at the final follow-up. The mean stem-to-canal fill percentages were 97% ± 2.1% (anteroposterior view at midstem). For stem alignment, 40 hips (95.2%) of the femoral stem were positioned neutrally to 3° of varus with reference to the femoral shaft axis. The remaining two were positioned at 4° varus to 4° valgus. Radiographic evaluation showed good osteointegration of the implants in follow-up.ConclusionsBased on the tapered-wedge design and proximal porous coating, the shortened tapered conventional stem can achieve reliable stability through neck filling and metaphyseal fixation, which does not depend on the isthmus hoop stress. This stem was suitable in severe osteoporotic patients with Type C bones in young adults who presented with a correspondingly straightened femoral canal with a wide isthmus and thin cortex.


2013 ◽  
Vol 5 (4) ◽  
pp. 34 ◽  
Author(s):  
Fritz Thorey ◽  
Claudia Hoefer ◽  
Nima Abdi-Tabari ◽  
Matthias Lerch ◽  
Stefan Budde ◽  
...  

In recent years, various uncemented proximal metaphyseal hip stems were introduced for younger patients as a bone preserving strategy. Initial osteodensitometric analyses of the surrounding bone of short stems indicate an increase of bone mass with secondary bone ingrowth fixation as a predictor of long-term survival of these types of implants. We report the outcome of 151 modular Metha short hip stem implants in 148 patients between March 2005 and October 2007. The mean follow-up was 5.8±0.7 years and the mean age of the patients was 55.7±9.8 years. Along with demographic data and co-morbidities, the Harris Hip Score (HHS), the Hip dysfunction and Osteoarthritis Outcome Score (HOOS), and also the results of a patient-administered questionnaire were recorded pre-operatively and at follow-up. The mean HHS increased from 46±17 pre-operatively to 90±5 the HOOS improved from 55±16 pre-operatively to 89±10 at the final follow-up. A total of three patients have been revised, two for subsidence with femoral revision and one for infection without femoral revision (Kaplan Meier survival estimate 98%). The radiological findings showed no radiolucent lines in any of the patients. The modular Metha short hip stem was implanted in younger patients, who reported an overall high level of satisfaction. The clinical and radiographic results give support to the principle of using short stems with metaphyseal anchorage. However, long-term results are necessary to confirm the success of this concept in the years to come.


2019 ◽  
Vol 48 (6) ◽  
pp. 1526-1534
Author(s):  
Sarah L. Chen ◽  
David R. Maldonado ◽  
Cammille C. Go ◽  
Cynthia Kyin ◽  
Ajay C. Lall ◽  
...  

Background: There is a plethora of literature on outcomes after hip arthroscopic surgery in the adult population; however, outcomes in the adolescent population have not been as widely reported. Additionally, as adolescents represent a very active population, it is imperative to understand their athletic activity and return to sport after hip arthroscopic surgery. Purpose: To analyze patient-reported outcomes (PROs) after hip arthroscopic surgery in adolescents (aged 10-19 years) and present a return-to-sport analysis in the athletic adolescent subgroup. Study Design: Systematic review; Level of evidence, 4. Methods: The PubMed, Embase, and Cochrane databases were searched according to the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines to identify articles that reported PROs after hip arthroscopic surgery in adolescents. The standardized mean difference was calculated to compare the effect size of hip arthroscopic surgery on various PROs. For the athletic subgroup, a return-to-sport summary was also provided. Results: Ten studies, with 618 adolescent hips and a collective study period of December 2004 to February 2015, were included in this systematic review. Across all studies, the mean age was 15.8 years (range, 11.0-19.9 years), and female patients composed approximately 56.7% of the entire cohort. The mean follow-up was 34.5 months (range, 12-120 months). The modified Harris Hip Score (mHHS) was reported in 9 studies, and at latest follow-up, scores were excellent in 4 studies (range, 90-95) and good in the remaining 5 studies (range, 82.1-89.6). All adolescents also showed significant improvement on the Non-Arthritic Hip Score (NAHS), the Hip Outcome Score–Activities of Daily Living (HOS-ADL), the HOS–Sport-Specific Subscale (HOS-SSS), the physical component of the 12-Item Short Form Health Survey (SF-12P), a visual analog scale for pain (VAS), and both versions of the International Hip Outcome Tool (iHOT-12 and iHOT-33) at latest follow-up ( P < .05). Further, mean improvements reported in all studies surpassed reported values of the minimal clinically important difference and patient acceptable symptomatic state for the mHHS, HOS-ADL, HOS-SSS, and iHOT-33. Finally, the collective return-to-sport rate among athletic adolescents was 84.9%. Conclusion: In the setting of labral tears and femoroacetabular impingement, hip arthroscopic surgery can safely be performed in adolescents and leads to significant functional improvement. Furthermore, athletic adolescents return to sport at high levels after hip arthroscopic surgery.


2018 ◽  
Vol 29 (1) ◽  
pp. 65-71 ◽  
Author(s):  
Yoshitoshi Higuchi ◽  
Taisuke Seki ◽  
Yukiharu Hasegawa ◽  
Yasuhiko Takegami ◽  
Daigo Morita ◽  
...  

Introduction: This study aimed to compare the clinical and radiographic results of 28-mm ceramic-on-ceramic (CoC) total hip arthroplasty (THA) to those of 32-mm CoC during a 5- to 15-year follow-up period. Methods: 107 joints (95 women and 6 men) underwent 28-mm CoC, and 60 (49 women and 7 men) underwent 32-mm CoC. The average patient age at the time of surgery was 56.1 and 55.7 years in the 28-mm and 32-mm CoC groups, respectively. Clinical and radiologic measurements of all patients were analysed. Results: The mean preoperative Harris hip score (HHS) was similar in the 2 groups (28-mm, 58.9; and 32-mm, 58.5). However, at final follow-up, the mean HHS of the 32-mm CoC (91.8) was significantly better than that of the 28-mm CoC (88.2) ( p = 0.003), as were the ranges of motion (ROM) for flexion (98.3 ± 13.5° vs. 87.3 ± 19.3°, p < 0.001) and abduction (27.8 ± 14.9° vs. 22.1 ± 19.3°, p = 0.007). The mean wear rate was 0.0044 mm/year for the 28-mm CoC and 0.0044 mm/year for the 32-mm CoC. No ceramic fractures were found in the 2 groups. One joint in the 28-mm CoC (0.9%) required revision owing to progressive osteolysis. Kaplan-Meier survival at 10 years, with implant loosening or revision THA as the endpoint, was 98.3% for 28-mm CoC and 100% for 32-mm CoC ( p = 0.465). Conclusion: There was no significant difference in ceramic-related complications between the 2 groups. Our study demonstrated that the 32-mm and 28-mm CoC are safe and are associated with good clinical outcomes.


2017 ◽  
Vol 28 (1) ◽  
pp. 59-62 ◽  
Author(s):  
Gregor Kavčič ◽  
Pika Mirt ◽  
Klemen Bedenčič

Introduction and methods: From January 2004 to December 2008, 188 total hip arthroplasties were performed using a cemented dual mobility cup. 174 patients were available for final analysis. Their mean age was 76.8 (range 54-98 years). The mean follow-up was 7.7 years (range 5-10 years). Results: There were no dislocations. Survivorship rates of the femoral and acetabular components were 100% at a minimum of 5 years. At the latest follow-up, the mean Harris Hip Score significantly increased from 31.6 (only arthritic patients) points preoperatively to 84.5 points. No patients had progressive osteolysis, component migration, or loosening on radiographs. 2 patients presented with periprosthetic fractures treated conservatively. 2 patients presented with infection treated without implant removal and 1 patient presented with transient femoral palsy. Conclusions: The results of this consecutive series confirmed the good performance of the cemented dual mobility cup at mean 7.7 years follow-up with no revision and no dislocations.


2021 ◽  
Author(s):  
Yüksel Yaradılmış ◽  
Mustafa Okkaoğlu ◽  
Erdi Özdemir ◽  
Ahmet Ateş ◽  
İsmail Demirkale ◽  
...  

Abstract Background: As subtrochanteric femoral osteotomy extends the operating time and increases bleeding, it is a complex surgical procedure, which exposes the patient to complications. The aim of this study was to describe the controlled femoral cracking method as a safely reduction method and to present the results of this method used in hip arthroplasty without femoral osteotomy in high dislocated hip.Methods: A retrospective examination included 40 Crowe III/IV patients for whom shortening was not planned preoperatively. Femoral osteotomy was planned for Crowe III/IV patients who were expected to have >4cm lengthening according to the preoperative templating. Patients were evaluated in respect of functional results, limb length discrepancy (LLD) and complications. Of the 40 patients applied with surgery without shortening, controlled femoral cracking was required in 20 cases, and no additional procedure was required during reduction in 20 cases. The patients applied with controlled femoral cracking were evaluated in respect of functional results, operating time, actual LLD and complications.Results: The patients comprised 3 males and 37 females with a mean age of 53.7±9.54 years. The mean follow-up period was 38±6.54 months (range, 24-66 months). The Harris Hip Score (HHS) was mean 45.96 preoperatively and 89.44±6.4 (range, 84-99) postoperatively. LLD was determined as 3.4±0.7cm preoperatively and 0.7±0.5 cm (range, 0-2 cm) postoperatively (p<0.05). The final HHS was 88.2±6.3 in patients applied with controlled femoral cracking and 90.3±6.5 (range, 86-99) in those not applied with controlled femoral cracking (p=0.740). No increase in complications was observed in the patients applied with controlled femoral cracking.Conclusion: In patients where more than 4 cm of lengthening is not expected preoperatively, arthroplasty can be successfully managed without a shortening femoral osteotomy. The controlled femoral cracking technique is safe, does not increase LLD or nerve palsy rate, and shortens operating time with less blood loss.


2021 ◽  
Author(s):  
FIRAT OZAN ◽  
Murat Kahraman ◽  
Ali Baktır ◽  
Kürşat Gençer

Abstract Background: To evaluate the clinical features and results of the revision total hip arthroplasties (THA) in patients with catastrophic failures and metallosis. Methods: Fifteen hips of 14 patients with catastrophic failure and metallosis in hip arthroplasties were evaluated. They were followed for at least 4.2 years after the revision THA. Clinical evaluation was performed using Harris hip score. Osteolysis, loosening or presence of metallosis was evaluated with standard radiographs. Metallosis was evaluated intraoperatively according to the metallosis severity classification. Results: The mean time from failure until revision surgery was 9.4 years. It was observed that in the primary THA, metal-on-ceramic (MoC), ceramic-on-ceramic (CoC) and metal-on-conventional polyethylene (MoCPE) bearings were used in 1, 3 and 11 hips, respectively. Grade III metallosis was observed in all patients during revision surgeries. The mean Harris hip score increased from 55 points before revision THA to 75 points at the final follow-up. In revision arthroplasty, MoCPE and CoC bearings were used in 13 and 2 hips, respectively. The femoral stem was replaced in 5 hips. All acetabular cups, except that of one hip, were revised. Conclusions: Revisions of THAs with catastrophic failures and metallosis are quite challenging. Routine follow-up of arthroplasty patients is beneficial to examine for osteolysis, loosening, and asymmetric wear.


2020 ◽  
Author(s):  
Junmin Shen ◽  
Jingyang Sun ◽  
Haiyang Ma ◽  
Yinqiao Du ◽  
Tiejian Li ◽  
...  

Abstract Background: High hip center technique is still controversial about the survivorship of prothesis and postoperative complications. We aimed to show the utility of high hip center technique used in patients with Crowe II-III developmental dysplasia of the hip at the midterm follow-up and evaluated the clinical and radiographic results between different heights of hip center.Methods: We retrospectively evaluated 69 patients (85 hips) with Crowe II-III dysplasia who underwent a high hip center cementless total hip arthroplasty at a mean follow up of 8.9 years (range, 6.0-14.1years). The patients were divided into two groups according to the height of hip center, respectively group A (≥22mm and <28mm) and group B (≥28mm). Radiographic, functional and survivorship outcomes were evaluated.Results: The mean location of the hip center from the inter-teardrop was 25.1mm vertically and 30.0mm horizontally in the group A, and 33.1mm vertically and 31.4mm horizontally in the group B. There were no statistically significant differences between two groups in postoperative femoral offset, abductor lever arm, leg length discrepancy and cup inclination. At the final follow up, the mean WOMAC and Harris hip score were significantly improved in both groups. Of the 85 hips, 7 hips (8.2%) showed a positive Trendelenburg sign. Additionally, 6 patients (8.7%) presented with a limp. No significant differences were shown regarding the Harris hip score, WOMAC score, Trendelenburg sign and limp between two groups. The Kaplan-Meier implants survivorship rates at the final follow-up for all-causes revisions in the group A and group B were similar (96.7% [95% confidence interval, 90.5%-100%] and 96.2% [95% confidence interval, 89.0%-100%], respectively).Conclusions: The high hip center technique is a valuable alternative to achieve excellent midterm results for Crowe II-III developmental dysplasia of the hip. Further, we reported good results and could not demonstrate any significant differences in outcomes or survivorship between the groups with differing degrees of HHC in our study, however the relatively small sample size must be considered and larger comparative studies are required to confirm the value of high hip center technique.


Sign in / Sign up

Export Citation Format

Share Document