scholarly journals Ten-year comparison of two different techniques for femoral bone cavity preparation—broaching versus compaction in patients with cementless total hip arthroplasty

2021 ◽  
Vol 2 (12) ◽  
pp. 1035-1042
Author(s):  
Maciej Okowinski ◽  
Mette Holm Hjorth ◽  
Sebastian Breddam Mosegaard ◽  
Jonathan Hugo Jürgens-Lahnstein ◽  
Stig Storgaard Jakobsen ◽  
...  

Aims Femoral bone preparation using compaction technique has been shown to preserve bone and improve implant fixation in animal models. No long-term clinical outcomes are available. There are no significant long-term differences between compaction and broaching techniques for primary total hip arthroplasty (THA) in terms of migration, clinical, and radiological outcomes. Methods A total of 28 patients received one-stage bilateral primary THA with cementless femoral stems (56 hips). They were randomized to compaction on one femur and broaching on the contralateral femur. Overall, 13 patients were lost to the ten-year follow-up leaving 30 hips to be evaluated in terms of stem migration (using radiostereometry), radiological changes, Harris Hip Score, Oxford Hip Score, and complications. Results Over a mean follow-up period of 10.6 years, the mean stem subsidence was similar between groups, with a mean of -1.20 mm (95% confidence interval (CI) -2.28 to -0.12) in the broaching group and a mean of -0.73 mm (95% CI -1.65 to 0.20) in the compaction group (p = 0.07). The long-term migration patterns of all stems were similar. The clinical and radiological outcomes were similar between groups. There were two intraoperative fractures in the compaction group that were fixed with cable wire and healed without complications. No stems were revised. Conclusion Similar stem subsidence and radiological and clinical outcomes were identified after the use of compaction and broaching techniques of the femur at long-term follow-up. Only the compaction group had intraoperative periprosthetic femur fractures, but there were no long-term consequences of these. Cite this article: Bone Jt Open 2021;2(12):1035–1042.

2020 ◽  
Author(s):  
Kai Zheng ◽  
Ning Li ◽  
Weicheng Zhang ◽  
Jun Zhou ◽  
Yaozeng Xu ◽  
...  

Abstract Background: Revision total hip arthroplasty is frequently accompanied by bone loss. The purpose of this study is to evaluate mid- to long-term results of revision total hip arthroplasty for massive femoral bone loss using cementless modular, fluted, tapered stems.Methods: During the period of 2007 to 2015 at a single hospital, 34 hips (33 patients) underwent primary revision surgery with cementless modular, fluted, tapered stems due to massive bone loss, and patients with prosthetic joint infection (PJI) or tumours were excluded. The hips were revised with the LINK MP (Waldemar Link, Hamburg, Germany) prosthesis. Bone loss was categorized by the Paprosky classification for prosthesis loosening and Vancouver classification for peri-prosthetic fracture. All revision bearing surfaces were ceramic-on-ceramic (CoC). Clinical outcomes, radiographic outcomes and survivorship were evaluated.Results: The mean follow-up was 9.1±2.5 years (range, 5-13 years). The Harris hip score was 43.6±11.5 preoperatively and maintained at 86.5±6.6 at the time of latest follow-up (p<0. 05). The X-ray showed bone ingrowth fixation in 30 hips (88%), fibrous stable fixation in 3 hips (9%) and instability in 1 hip (3%). The average stem subsidence was 3.9±2.2 mm (range, 1 to 10 mm). The survivorship of prostheses with re-revision for any reason was 95% (95% CI, 12.0 to 13.0) at the 10-year follow-up. Three (9%) re-revisions were needed, including 1 for aseptic loosening, 1 for dislocation and 1 for infection.Conclusions: The mid- to long-term results of revision total hip arthroplasty with the cementless modular, fluted, tapered stem (LINK MP stem) are encouraging for massive femoral bone loss.


Joints ◽  
2020 ◽  
Author(s):  
Christian Carulli ◽  
Giacomo Sani ◽  
Fabrizio Matassi ◽  
Roberto Civinini ◽  
Massimo Innocenti

Abstract Purrpose Metal-on-metal (MoM) total hip arthroplasty (THA) has been a subject of recent discussion and concern due to the early failures caused by local and systemic adverse reactions related to specific designs. The aim of this study is to analyze the outcomes and survival rates of a single brand of MoM implants implanted in a consecutive series of patients at a single institution. Methods Between 2007 and 2012, 116 (118 hips) patients were evaluated at a mean follow-up of 6.6 years after primary THA. The diagnosis leading to surgery was osteoarthritis (80 patients) and proximal femoral fracture (36 patients). A single design of THA was implanted. All patients were evaluated before surgery and postoperatively at 1, 3, 6, and 12 months by clinical scores and radiographic studies. The data analysis was made using Student's t-test. Results The minimum follow-up was of 4 years, with a mean follow-up of 6.6 years. Two aseptic loosenings of the acetabular component were recorded (one per group), which were not associated with local or systemic complications related to metal ion release. Both were revised by an isolated acetabular cup substitution with metal-on-polyethylene couplings. Nonprogressive radiolucency lines < 2 mm in zone 2 were observed in other six patients around the acetabular component without clinical manifestation (four in the arthritis group and two in the fracture group). Postoperative Harris Hip Score and SF-36 (36-Item Short Form Survey) score improved in both groups. Conclusion Despite several MoM implants showing early complications and failures, a specific MoM design may be associated with good clinical results at a mid- to long-term follow-up. Level of Evidence This is a therapeutic case series, Level 4 study.


2020 ◽  
Author(s):  
Wenli Chen ◽  
Mao Shuai ◽  
Jinluan Lin ◽  
Baomin Chen ◽  
Mingdong Zhao ◽  
...  

Abstract Background A high rate of complications due to metal-on-metal (MoM) revisions has been relatively commonly documented. The purpose of this retrospective study was to compare the long-term outcomes of patients who had undergone uncemented or cemented total hip arthroplasty (THA) revision for prior primary MoM THA failure.Methods Data from 234 patients (234 hips) who underwent uncemented or cemented THA (UTHA or CTHA) for prior primary MoM THA failure during 2007 - 2018 were retrospectively analysed. Follow-up occurred 3 months, 6 months, 1 year, 2 years, and then every 1 year after conversion. The mean follow-up time was 84.15 months (range, 67 - 101 months). The primary endpoint was the modified Harris Hip Score (HHS). The secondary endpoint was the major orthopaedic complication rate.Results The HHS demonstrated statistically greater differences in the CTHA group than in the UTHA group 12 months after conversion. From the 12th month after conversion to the final follow-up, CTHA yielded better functional outcomes than UTHA. There were significant differences in the rates of re-revision, aseptic loosening, and periprosthetic fracture between the groups (10.3% for UTHA vs 2.5% for CTHA, p = 0.015; 16.3% for UTHA vs 5.9% for CTHA, p = 0.011; and 12.0% for UTHA vs 4.2% for CTHA, p = 0.045, respectively).Conclusion In the setting of revision for primary MoM THA failure, we found definite evidence of the superiority of CTHA over UTHA in terms of improving functional outcomes and decreasing the major orthopaedic complication rate.


10.29007/455b ◽  
2018 ◽  
Author(s):  
Itay Perets ◽  
John Walsh ◽  
Brian Mu ◽  
Yosif Mansor ◽  
Leslie Yuen ◽  
...  

Recent advances have made robotic assistance a viable option in total hip arthroplasty (THA). However, the clinical outcomes of this procedure relative to THA without robotic assistance have yet to be reported. This study presents short-term outcomes of robotically assisted THA compared to a pair-matched control group of patients that underwent THA without robotic assistance.Data were prospectively collected on all THAs performed from July 2011 to January 2015. Patients were included if they underwent primary THA treating idiopathic osteoarthritis and were eligible for minimum two-year follow-up. Outcomes were measured using Harris Hip Score (HHS), the Forgotten Joint Score (FJS-12), pain on a visual analog scale (VAS), and satisfaction from 0-10. Patients that underwent THA with robotic assistance were matched 1:1 with THA patients without robotic assistance for age, sex, BMI, and approach.There were 85 patients in each study group. There were no significant differences in the demographic factors matched for. Both HHS and FJS-12 were significantly higher in the robotic assistance group at minimum two-year follow-up. VAS was lower in the robotic assistance group, but this was not statistically significant (p = 0.12). There was a not a significant difference in patient satisfaction. There was no significant difference in the rate of postoperative complications or subsequent revisions between groups.Robotically assisted THA is safe and may lead to superior short-term outcomes compared to THA without robotic assistance.


Arthroplasty ◽  
2019 ◽  
Vol 1 (1) ◽  
Author(s):  
Seung-Jae Lim ◽  
Ingwon Yeo ◽  
Chan-Woo Park ◽  
Kyung-Jae Lee ◽  
Byung-Woo Min ◽  
...  

Abstract Purpose Highly cross-linked polyethylene has been introduced to decrease osteolysis secondary to polyethylene wear debris generation. However, few long-term data on revision total hip arthroplasty (THA) using highly cross-linked polyethylene liners are available. The objective of this study was to determine long-term outcomes of a highly cross-linked polyethylene liner in revision THA. Materials & methods We evaluated 63 revision THAs performed in 63 patients using a highly cross-linked polyethylene liner between April 2000 and February 2005. Of these, nine died and four were lost to follow-up. Thus, the final study cohort consisted of 50 patients (50 hips), including 26 males and 24 females with a mean age of 53 years (range, 27–75 years). Mean follow-up was 11 years (range, 10–14 years). Results The mean Harris hip score improved from 44 points preoperatively to 85 points at the final follow-up. No radiographic evidence of osteolysis was found in any hip. The mean rate of polyethylene liner wear was 0.029 mm/year (range, 0.003 to 0.098 mm/year). A total of 5 hips (10%) required re-revision arthroplasty, including one cup loosening, one recurrent dislocation, and three deep infections. Kaplan-Meier survivorship with an end point of re-revision for any reason was 91.1% and for aseptic cup loosening was 97.9% at 11 years. Conclusion At a minimum of 10 years, the highly cross-linked polyethylene liners showed excellent clinical performance and implant survivorship, and were not associated with osteolysis in our patients with revision THAs.


2020 ◽  
Author(s):  
Wenli Chen ◽  
Mao Shuai ◽  
Jinluan Lin ◽  
Baomin Chen ◽  
Mingdong Zhao ◽  
...  

Abstract Background: Cemented or uncemented total hip arthroplasty (CTHA or UTHA) is being increasingly performed in patients with intertrochanteric femur fractures (IFFs) who failed to be treated with proximal femoral nail anti-rotations (PFNA) fixation. The purpose of this study is to compare the clinical outcomes of CTHA or UTHA following prior failed PFNA fixation in patients with IFFs.Methods: Data from 244 patients with IFFs who underwent a conversion of PFNA to CTHA (PCA, n =120) or to UTHA (PUA, n = 124) due to pain and hip disfunction during 2008-2018 were retrospectively analysed. Follow-up occurred 1, 3, 6, and 12 months postoperatively and yearly thereafter. The mean follow-up was 64 months (range, 57 – 71 months). The Harris hip score (HHS) was the primary outcome; the incidence of major orthopaedic complications was the secondary outcome.Results: At the final follow-up, HHS was 79.54±18.85 vs 75.26±18.27 (PCA vs PUA, p = 0.014). There were significant differences between groups regarding the incidence of prosthesis revision, prosthesis loosening, and periprosthetic fracture (5.8% for PCA vs 14.5% for PUA, p = 0.025; 10.0% for PCA vs 20.1% for PUA, p = 0.027; 3.3% for PCA vs 10.5% for PUA, p = 0.028, respectively). Conclusion: The results of the study demonstrated a significant advantage with respect to HHS and major orthopaedic complication rate in favor of CTHA, as compared to UTHA in patients with a failed PFNA treatment.


2020 ◽  
Author(s):  
Edward Thomas Davis ◽  
Ville Remes ◽  
Petri Virolainen ◽  
Peter Gebuhr ◽  
Bart Van Backlé ◽  
...  

Abstract Background: Whilst bony fixation of hip replacement has stable solutions, there remains controversy over which bearing best optimizes longevity and function. Ceramic-on-ceramic (CoC) bearing combinations are associated with lower risk of revision due to aseptic loosening and dislocation. Evidence for long-term functional outcomes of modern, 4th generation CoC bearings is limited. The aim of this study was to analyze outcomes and complications of the R3™ Acetabular System (Smith & Nephew, Inc., Cordova, TN, USA) in combination with BIOLOX® Delta ceramic femoral head in patients undergoing primary total hip arthroplasty (THA).Methods: Between June 2009 and May 2011, 175 patients (178 hips) were enrolled into a prospective, study at 6 sites in Europe and prospectively followed-up at 3 months and 1, 3, 5, and 7 years postoperative. Results: Total WOMAC score improved from 63 (range, 22-91) preoperative to 8 (range, 0- 8) at 1-year follow-up and remained unchanged at 7-year follow-up. Modified Harris Hip Score improved from 45 (range, 10-87) preoperative to 83 (range, 25-100) at 3 months, 91 (range, 42-100) at 1 year, and 92 (range, 46, 100) at 7 years. UCLA Activity Rating Scale score improved from 3.3 (range, 1-8) preoperative to 6.2 (range, 2-8) at 1 year; it marginally declined to 5.8 (range, 3-8) at 7-year follow-up. There were 4 trochanteric fractures and 5 patients died of unrelated reasons. Three hips were revised (2 periprosthetic fractures and 1 subluxation). The 7-year cumulative survival rate was 98.3%. Conclusion: Clinical and functional improvements of THA with CoC bearing are maintained at 7 years postoperative.


Author(s):  
Tiejian Liu ◽  
Xiaoxiao Hua ◽  
Weiguang Yu ◽  
Jinluan Lin ◽  
Mingdong Zhao ◽  
...  

Abstract Background This retrospective analysis compared the long-term outcomes for patients with a femoral neck fracture (AO/OTA type 31B) treated with a primary unilateral total hip arthroplasty with uncemented or cemented femoral components (UTHA or CTHA, respectively). Methods We conducted a retrospective cohort study using the South China Hip Arthroplasty Database. We identified 422 patients with femoral neck fracture (AO/OTA type 31B) who were previously treated with primary unilateral UTHA or CTHA between 2007 and 2015, with follow-up until 2019. Follow-up occurred 1, 3, 6 and 12 months postoperatively and yearly thereafter. The primary outcome was the Harris hip score (HHS). The secondary outcome was the orthopaedic complication rate. Results In total, 324 patients (UTHA n = 160, mean age 68.61 ± 7.49 years; CTHA n = 164, mean age 68.75 ± 7.04 years) were evaluated for study eligibility. The median follow-up was 73.3 months (range, 11.6–89.2 months). At the final follow-up, HHS was 74.09 ± 6.23 vs 79.01 ± 10.21 (UTHA vs CTHA, p = 0.012). Significant differences were detected in the incidence of prosthetic revision, loosening, and periprosthetic fracture between the UTHA and CTHA groups (7.5% for UTHA vs 1.8% for CTHA, p = 0.015; 17.5% for UTHA vs 8.5% for CTHA, p = 0.016; 11.9% for UTHA vs 4.9% for CTHA, p = 0.021, respectively). Conclusion In this setting, CTHA demonstrated superiority to UTHA by improving functional outcomes and decreasing complication rates.


2019 ◽  
Vol 25 (3) ◽  
pp. 25-33
Author(s):  
V. V. Danilyak ◽  
V. V. Klyuchevsky ◽  
M. A. Molodov ◽  
E. V. Goryunov ◽  
K. V. Marchenkova

Relevance. The RM Classic monoblock titanium-coated polyethylene cup is widely used in the total hip arthroplasty. However, so far in Russia there has been no analysis of follow-up over 10 years for a limited number of patients in a single hospital. The aim of the study was to evaluate the long-term outcomes of total hip replacement with RM Classic acetabular component. Materials and Methods. The outcomes of 328 total hip arthroplasties (289 patients operated in the period from 1997 to 2007) with RM Classic cups were evaluated in a monocentral retrospective clinical study. The average follow-up period was 14.4 years. Revision procedure due to aseptic loosening, polyethylene wear or osteolysis was considered as the end point of the study. Results. 9 revisions during the short and medium follow-up periods (up to 10 years) were associated with malpositioning of RM Classic components and errors in surgical technique. The indications for later revision THA (19 cases) were polyethylene wear and aseptic loosening. Only in one case they were combined with pelvic bone osteolysis with the formation of III a defect according to W.G. Paprosky classification. Within 15 years the Kaplan-Meier survivorship of RM Classic cup was 92.5%. There was a statistically significant difference of the survival curves in the ceramic-on-poly against metal-on-poly bearings: 94.9% and 79.4%, respectively. The average Harris Hip Score was 88.6. Conclusion. RM Classic uncemented monoblock cup has proven its high efficiency and survival in 15 years follow-up period and over.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Mumingjiang Yishake ◽  
Lan Tang ◽  
Xi Chen ◽  
Yuejian Wang ◽  
Rongxin He

Abstract Background Total two-stage exchange is commonly used in clinical practice as a treatment for infected total hip arthroplasty (THA); however, this approach involves considerable limitations, including significant bone loss and severe trauma. This retrospective cohort study was conducted to evaluate clinical outcomes following the use of partial two-stage exchange (PTE) for infected THA. Methods We performed a retrospective analysis of 28 patients with infected THA who were treated by PTE between September 2000 and June 2019. Eligibility for PTE was limited to patients with a well-fixed femoral stem prosthesis. In the first stage of the operation, the femoral stem prosthesis was preserved; subsequently, the acetabular prosthesis, liner, and head were replaced with an antibiotic-loaded spacer. The new prosthesis was then implanted into patients and monitored for at least 3 months to ensure freedom from infection. Results Patients were followed for an average of 4 years (range, 2–11 years), with an overall success rate of 85.7% (24/28). The mean Harris hip score at the final follow-up was 76.2 ± 11.7 points. Conclusions The findings of this study suggest that PTE could be an acceptable option for a subset of patients with infected THA, offering a satisfactory infection control rate and clinical outcomes comparable to those of total two-stage exchange, but with less harm.


Sign in / Sign up

Export Citation Format

Share Document